Mini-Beam HP 2' x 2' Recessed Fluorescent MBS2GHP224 or 1 FT

Page 1 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5

  • Features
  • Direct/indirect lamp shield appearance with soft contoured interior.
  • Four inch wide with white acrylic lens.
  • 85.3% efficient (2 lamp 24W).
  • 83.3% efficient (1 lamp 40W).
  • 1.4 spacing mounting ratio (2 lamp 24W).
  • 1.5 spacing mounting ratio (1 lamp 40W).
  • Only 5-1/2" deep.
  • Same fixture fits both G and T ceiling types.
  • Fits flush to face of slot grid (T) ceiling types.
  • Lamp shield hinges from either side.
  • Hinged external ballast housing compartment.
  • Can be continuous row mounted.
  • Wiring access plate standard.
  • 4 hold-down clips standard.
  • Housing is 20 gauge steel, meets NYC Code requirements.
  • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Lightolier MBS2GHP1FT — Mini-Beam HP 2' x 2' Recessed Fluorescent MBS2GHP224 or 1 FT diagram (page 1)
図 1 · Mini-Beam HP 2' x 2' Recessed Fluorescent MBS2GHP224…

Mounting Methods Dimensions

Lightolier MBS2GHP1FT — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier MBS2GHP1FT — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions

Hinged external ballast housing compartment

Lightolier MBS2GHP1FT — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by others

1-1/2" max.

1-7/8" max.

Acoustical material by others

Acoustical material by others

Lightolier MBS2GHP1FT — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions

2" x 2-1/2" access plate with (2) 7/8" dia. K.O.s 3-1/2" (89mm)

exposed slot t-grid ceiling

Features

Lightolier MBS2GHP1FT — Features diagram (page 1)
図 6 · Features
Lightolier MBS2GHP1FT — Features diagram (page 1)
図 7 · Features

Hinged external ballast housing compartment

hinged external ballast housing compartment

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M20-28
Show 12 more labels / short text on this page
5-1/2" (139mm) · 4" (102mm) · 24" (610mm) · 15/16" · 9/16" · 24" · 24" · exposed t-grid ceiling · Ballast · hold-down clips · 24" (610mm) · 2/06
Page 2 of the Lightolier MBS2GHP1FT user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Mini-Beam HP 2' x 2' Recessed Fluorescent MBS2GHP224 or 1FT

Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5

Model No. MBS2GHP224UNVPG LER = FP -64.4 IW - 52.8 BF - 1.00 Comparative yearly lighting energy cost per

Model No. MBS2GHP1FT120SB LER = FP - 68.5 IW - 39.7 BF - 1.0 Comparative yearly lighting energy cost per

CANDELA DISTRIBUTION 0

1000 lumens = $3.73

1000 lumens = $3.64

CANDELA DISTRIBUTION 0

Lightolier MBS2GHP1FT — CANDELA DISTRIBUTION 0 diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Lightolier MBS2GHP1FT — 0.0 45.0 90.0 FLUX diagram (page 2)
図 9

0.0 45.0 90.0 FLUX

Report Number: G2005301 Catalog Number: MBS2GHP224UNVPG Lamps: FP24/835 HO Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic

Report Number: G2005303 Catalog Number: MBS2GHP1FT120SB Lamps: 40W TT5 Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic

0 1021 1021 1021

0 778 778 778

5 1015 1030 1045 99

5 774 780 788 75

15 979 1035 1099 296

15 745 793 828 223

25 911 1030 1062 465

lens Ballast: RCN-1TTP40-SC Report is based on 3150 Lumens per lamp. Efficiency: 83.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800

lens Ballast: Triad B224PUNV-D Report is based on 2000 Lumens per lamp. Efficiency: 85.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

25 689 777 811 352

35 814 939 949 571

35 610 720 754 440

45 687 800 873 613

45 513 632 684 476

55 532 637 713 566

55 399 501 543 437

65 348 449 520 439

65 270 350 395 339

75 169 285 355 286

75 136 219 268 220

85 31 79 94 79

85 28 64 80 64

90

90 2 2 2

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 92 88 84 82 80 77 79 77 74 02 84 76 70 72 67 63 69 65 61 03 76 67 59 63 57 52 60 55 51 04 69 59 51 55 49 44 53 48 43 05 64 52 44 49 43 38 48 42 37 06 59 47 39 45 38 33 43 37 33 07 54 42 35 40 34 29 39 33 29 08 50 39 31 37 30 26 36 30 26 09 47 35 28 34 28 23 33 27 23 10 44 34 26 31 25 21 30 25 21

01 90 86 82 80 78 75 77 75 73 02 82 74 68 70 65 61 67 63 60 03 74 65 58 61 55 51 59 54 50 04 68 57 50 54 48 43 52 47 42 05 62 51 43 48 42 37 46 41 36 06 57 46 38 43 37 32 42 36 32 07 53 41 34 39 33 28 38 32 28 08 49 38 30 36 30 25 35 29 25 09 46 34 27 33 27 22 32 26 22 10 43 32 25 30 24 20 30 24 20

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 860 21.5 25.2 00-040 1431 35.8 41.9 00-060 2610 65.2 76.5 00-090 3413 85.3 100.0 90-180 0000 0.0 000.0 00-180 3413 85.3 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 650 20.6 24.8 00-040 1090 34.6 41.5 00-060 2002 63.6 76.3 00-090 2625 83.3 100.0 90-180 0000 00.0 000.0 00-180 2625 83.3 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2866. 3337. 3641. 55 2736. 3276. 3666. 65 2429. 3134. 3629. 75 1926. 3248. 4046. 85 1049. 2673. 3131.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2162. 2664. 2883. 55 2073. 2603. 2822. 65 1904. 2468. 2786. 75 1566. 2522. 3086. 85 958. 2189. 2736.

Ordering Information Explanation of Catalog Number. Example: MBS2GHP224UNVPG

S

G

HP

Body Style:

S = Static Lamp Quantity1 = 1 Lamp 2 = 2 Lamp

Ceiling Type:

High Performance Prismatic Lens

Lamp Type:

Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Fits both Standard Grid

(By others) FT = Twin Tube T5 14 = T5 14 Watt 24 = T5HO 24 Watt (Nominal 24")

no, ie(GLR)

Ballast Type:

MB Standard Mini-Beam

M3 For NYC Code –Local 3 Manufactured

Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.

Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3629 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–white virgin acrylic lens. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M20-28
Show 5 more labels / short text on this page
Mini-Beam Direct/Indirect · Fixture · Width · Recessed · and Slot Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier MBS2GHP1FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier MBS2GHP1FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier MBS2GHP1FT 取扱説明書(PDF)

2 ページ·148 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…