Page 1 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5



Hinged external ballast housing compartment

Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

2" x 2-1/2" access plate with (2) 7/8" dia. K.O.s 3-1/2" (89mm)
exposed slot t-grid ceiling


Hinged external ballast housing compartment
hinged external ballast housing compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5
Model No. MBS2GHP224UNVPG LER = FP -64.4 IW - 52.8 BF - 1.00 Comparative yearly lighting energy cost per
Model No. MBS2GHP1FT120SB LER = FP - 68.5 IW - 39.7 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.73
1000 lumens = $3.64


Report Number: G2005301 Catalog Number: MBS2GHP224UNVPG Lamps: FP24/835 HO Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic
Report Number: G2005303 Catalog Number: MBS2GHP1FT120SB Lamps: 40W TT5 Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic
0 1021 1021 1021
0 778 778 778
5 1015 1030 1045 99
5 774 780 788 75
15 979 1035 1099 296
15 745 793 828 223
25 911 1030 1062 465
lens Ballast: RCN-1TTP40-SC Report is based on 3150 Lumens per lamp. Efficiency: 83.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
lens Ballast: Triad B224PUNV-D Report is based on 2000 Lumens per lamp. Efficiency: 85.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
25 689 777 811 352
35 814 939 949 571
35 610 720 754 440
45 687 800 873 613
45 513 632 684 476
55 532 637 713 566
55 399 501 543 437
65 348 449 520 439
65 270 350 395 339
75 169 285 355 286
75 136 219 268 220
85 31 79 94 79
85 28 64 80 64
90
90 2 2 2
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 92 88 84 82 80 77 79 77 74 02 84 76 70 72 67 63 69 65 61 03 76 67 59 63 57 52 60 55 51 04 69 59 51 55 49 44 53 48 43 05 64 52 44 49 43 38 48 42 37 06 59 47 39 45 38 33 43 37 33 07 54 42 35 40 34 29 39 33 29 08 50 39 31 37 30 26 36 30 26 09 47 35 28 34 28 23 33 27 23 10 44 34 26 31 25 21 30 25 21
01 90 86 82 80 78 75 77 75 73 02 82 74 68 70 65 61 67 63 60 03 74 65 58 61 55 51 59 54 50 04 68 57 50 54 48 43 52 47 42 05 62 51 43 48 42 37 46 41 36 06 57 46 38 43 37 32 42 36 32 07 53 41 34 39 33 28 38 32 28 08 49 38 30 36 30 25 35 29 25 09 46 34 27 33 27 22 32 26 22 10 43 32 25 30 24 20 30 24 20
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 860 21.5 25.2 00-040 1431 35.8 41.9 00-060 2610 65.2 76.5 00-090 3413 85.3 100.0 90-180 0000 0.0 000.0 00-180 3413 85.3 100.0
ZONE LUMENS % LAMP % FIXT 00-030 650 20.6 24.8 00-040 1090 34.6 41.5 00-060 2002 63.6 76.3 00-090 2625 83.3 100.0 90-180 0000 00.0 000.0 00-180 2625 83.3 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2866. 3337. 3641. 55 2736. 3276. 3666. 65 2429. 3134. 3629. 75 1926. 3248. 4046. 85 1049. 2673. 3131.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2162. 2664. 2883. 55 2073. 2603. 2822. 65 1904. 2468. 2786. 75 1566. 2522. 3086. 85 958. 2189. 2736.
S
G
HP
Body Style:
Ceiling Type:
High Performance Prismatic Lens
Lamp Type:
Fits both Standard Grid
(By others) FT = Twin Tube T5 14 = T5 14 Watt 24 = T5HO 24 Watt (Nominal 24")
Ballast Type:
M3 For NYC Code –Local 3 Manufactured
Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.
Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3629 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–white virgin acrylic lens. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.