Page 1 of 2 Direct/Indirect, Static, 1 Lamp, Linear T5, 54 Watt or 28 Watt




Hinged external ballast housing compartment
Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others
Exposed slot t-grid ceiling
2" x 2" access plate with two K.O.’s (7/8" dia.) 3-1/2" (89mm)



Hinged external ballast housing compartment
Hinged external ballast housing compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect, Static, 1 Lamp, Linear T5, 54 Watt or 28 Watt
LER = FL -56.2 IW - 61.1 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $7.40

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 85 82 78 76 74 72 73 71 70 2 77 71 66 67 63 59 64 61 58 3 71 63 56 59 54 50 57 53 49 4 65 55 49 52 47 42 51 46 42 5 59 49 42 46 40 36 45 39 35 6 54 43 36 45 35 31 40 35 31 7 50 39 32 37 31 27 36 31 27 8 46 35 28 33 27 23 32 27 23 9 42 31 25 30 24 20 29 24 20 10 39 28 22 27 21 18 26 21 17 visual comfort probability (rated lumens per lamp .)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 66 73 83 91 59 67 80 90 20 30 61 66 73 82 54 57 66 77 20 40 59 62 68 74 54 55 58 66 20 60 58 61 64 70 53 55 56 60 30 20 65 71 81 89 60 68 78 88 30 30 60 64 70 79 56 58 64 75 30 40 58 60 65 71 54 55 57 64 30 60 57 59 61 66 54 54 54 57 30 80 57 59 60 64 54 55 53 56 40 20 66 71 80 88 63 69 78 87 40 30 61 64 69 77 58 59 65 74 40 40 58 60 63 69 56 56 57 63 40 60 58 58 59 64 55 55 54 56 40 80 58 58 58 61 56 55 53 55 40 100 59 59 58 60 56 56 53 54 60 30 63 65 68 76 60 61 65 74 60 40 60 61 62 68 58 58 57 63 60 60 59 59 58 62 57 56 54 56 60 80 59 58 56 59 57 56 53 54 60 100 60 59 56 58 57 56 53 53 100 40 64 65 64 68 63 62 61 66 100 60 63 62 60 62 61 60 57 58 100 80 62 61 58 59 60 59 55 56 100 100 63 61 57 58 61 59 55 54
MB
S
G
P
W
Body Style:
Ceiling Type:
Fits both Standard Grid
Lamp Quantity:
(By others) 54 = HO/T5 54 Watt 28 = 28 Watt T5
Instant Start Less than 10 THD PG = Programmed
Start Less than 10 THD
For Local 3 Manufacturing
DA = DALI digital
MB
Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.
Specifications Performance: In an installation of 1 lamp 54W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .82. To reduce glare the average brightness at 65° shall not exceed 2146 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.9%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–baked flat white acrylic enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.