Page 1 of 2 Direct/Indirect, Static, 1 Lamp, TT5, 55, 50 or 40 Watt



Hinged external ballast housing compartment

Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

2" x 2" access plate with two K.O.’s (7/8" dia.) 3-1/2" (89mm)
Exposed slot t-grid ceiling


Hinged external ballast housing compartment
Hinged external ballast housing compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect, Static, 1 Lamp, TT5, 55, 50 or 40 Watt
LER = FL - 47.8 IW - 60.9 BF - 0.92 Comparative yearly lighting energy cost per 1000 lumens = $5.02

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 72 69 66 64 62 60 62 60 58 2 65 59 55 56 52 49 54 51 48 3 59 52 46 49 44 41 47 43 40 4 54 46 40 43 38 34 42 37 34 5 50 41 35 39 33 29 37 33 29 6 46 37 30 35 30 26 34 29 25 7 42 33 27 31 26 23 30 26 22 8 39 30 24 29 24 20 28 23 20 9 37 28 22 26 22 18 26 21 18 10 34 25 20 24 20 16 24 19 16 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 56 64 75 86 46 55 69 83 20 30 53 57 64 74 41 44 52 66 20 40 53 55 60 66 39 41 45 53 20 60 53 55 57 61 38 39 41 46 30 20 55 62 72 83 49 56 68 80 30 30 51 55 61 70 43 45 51 63 30 40 51 52 56 62 40 41 43 50 30 60 51 52 53 57 38 39 39 43 30 80 52 53 52 56 39 39 38 41 40 20 56 61 70 80 52 58 68 79 40 30 52 54 59 68 45 47 52 63 40 40 51 52 54 60 42 43 44 50 40 60 51 51 51 55 40 41 40 43 40 80 52 52 51 53 40 40 38 40 40 100 53 53 51 53 41 40 38 39 60 30 53 55 58 66 48 50 53 63 60 40 52 52 53 58 45 45 45 50 60 60 51 51 50 53 42 42 40 43 60 80 52 51 49 51 42 41 38 40 60 100 53 52 50 51 42 41 38 39 100 40 55 55 54 58 50 50 49 54 100 60 54 53 51 53 47 46 44 46 100 80 55 53 50 51 46 45 41 43 100 100 55 54 50 50 47 44 40 40
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
MB
S
G
P
W
FT
Body Style:
Ceiling Type:
Fits both Standard Grid
For Local 3 Manufacturing
MB
Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.
Specifications Performance: In an installation of 1 lamp 55W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .69. To reduce glare the average brightness at 65° shall not exceed 3804 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–baked flat white acrylic enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.