Page 1 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt



Hinged external ballast housing compartment

Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

2" x 2" access plate with two K.O.’s (7/8" dia.) 3-1/2" (89mm)
Exposed slot t-grid ceiling


Hinged external ballast housing compartment
Hinged external ballast housing compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt
Photometry Model No. MBS2GPW224120PG
LER = FL - 41.9 IW - 52.0 BF - 1.00 Comparative yearly lighting energy cost per 1000 lumens = $5.72

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 68 65 62 61 59 57 58 57 55 2 62 56 52 53 50 47 51 48 46 3 56 50 44 47 43 39 45 42 39 4 51 44 38 41 37 33 40 36 33 5 47 38 33 36 32 28 35 31 28 6 43 34 29 32 28 24 31 27 24 7 39 31 25 29 24 21 28 24 21 8 36 27 22 26 21 18 25 21 18 9 33 25 19 23 19 15 23 18 15 10 31 22 17 21 17 14 21 16 13 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 64 71 82 91 54 62 76 88 20 30 60 64 72 81 47 52 60 73 20 40 59 62 67 73 45 48 53 61 20 60 59 61 64 69 43 46 48 54 30 20 62 69 79 88 56 63 75 86 30 30 58 62 68 77 49 53 59 71 30 40 57 59 63 69 46 48 52 59 30 60 57 58 60 65 44 46 47 51 30 80 57 59 59 63 43 45 45 49 40 20 63 69 77 86 59 65 75 85 40 30 59 61 67 75 52 55 60 71 40 40 57 59 61 67 48 50 52 58 40 60 57 57 58 62 45 47 47 51 40 80 57 58 57 61 45 46 44 48 40 100 58 58 57 60 45 45 44 46 60 30 59 62 66 73 54 57 61 70 60 40 58 59 60 65 50 52 53 59 60 60 57 57 57 60 47 48 47 51 60 80 57 57 56 58 46 46 45 47 60 100 58 58 56 58 46 46 43 45 100 40 60 61 61 66 56 56 56 61 100 60 59 59 57 60 52 52 50 53 100 80 59 58 56 58 50 50 47 49 100 100 60 59 56 57 49 49 46 47
MB
S
G
P
W
Body Style:
Ceiling Type:
Fits both Standard Grid
Lamp Quantity:
(By others) 24 = HO/T5 24 Watt
Instant Start Less than 10 THD PG = Programmed
Start Less than 10 THD
For Local 3 Manufacturing
DA = DALI digital
MB
Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.
Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .65. To reduce glare the average brightness at 65° shall not exceed 2725 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–baked flat white acrylic enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.