Page 1 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 54 Watt or 28 Watt




Hinged external ballast housing compartment
Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others
Exposed slot t-grid ceiling
2" x 2" access plate with two K.O.’s (7/8" dia.) 3-1/2" (89mm)



Hinged external ballast housing compartment
Hinged external ballast housing compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect, Static, 2 Lamp, Linear T5, 54 Watt or 28 Watt
LER = FL - 60.5 IW - 120.2 BF - 1.00 Comparative yearly lighting energy cost per 1000 lumens = $3.96

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 77 74 70 69 67 64 66 64 62 2 70 64 59 60 56 52 57 54 51 3 63 56 49 52 47 43 50 46 43 4 58 49 42 46 41 37 44 40 36 5 53 44 37 41 36 32 40 35 31 6 49 39 33 37 32 27 36 31 27 7 45 35 29 34 28 24 33 28 24 8 42 32 26 31 25 22 30 25 21 9 39 30 24 28 23 19 28 23 19 10 37 27 21 26 21 18 25 21 17 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 36 44 57 71 28 36 51 67 20 30 31 36 43 55 24 26 33 47 20 40 30 32 37 44 23 24 26 33 20 60 29 31 34 39 23 23 24 27 30 20 35 42 53 67 30 37 49 64 30 30 30 34 40 51 25 27 32 44 30 40 28 30 34 41 24 24 25 31 30 60 28 29 31 35 23 23 22 25 30 80 29 30 29 33 24 24 22 24 40 20 36 42 51 64 33 39 49 63 40 30 31 33 38 48 27 29 33 44 40 40 29 30 33 39 26 26 26 31 40 60 29 29 29 33 25 25 23 25 40 80 30 29 28 31 26 25 22 24 40 100 31 30 28 31 27 26 23 23 60 30 33 35 38 47 30 31 34 44 60 40 31 31 32 37 28 27 26 32 60 60 30 29 28 32 27 26 23 25 60 80 31 30 27 30 27 26 23 24 60 100 32 31 23 29 28 26 23 23 100 40 35 35 34 38 33 32 30 35 100 60 34 33 30 32 31 30 26 28 100 80 35 33 29 30 31 29 25 26 100 100 36 33 29 29 32 29 25 25
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
MB
S
G
P
W
Body Style:
Ceiling Type:
Fits both Standard Grid
Lamp Quantity:
(By others) 54 = HO/T5 54 Watt 28 = 28 Watt T5
Instant Start Less than 10 THD PG = Programmed
Start Less than 10 THD
For Local 3 Manufacturing
DA = DALI digital
MB
Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Electrical/Wiring Options: Consult factory.
Specifications Performance: In an installation of 2 lamps 54W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .74. To reduce glare the average brightness at 65° shall not exceed 8112 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%. Materials: Housing is die-formed 20 gauge steel. Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–baked flat white acrylic enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.