
Page 1 of 2 2'x2' RECESSED FLUORESCENT, 11/2" DEEP, 36 CELL PARABOLIC LOUVER, STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, T8, 1-5/8"U LAMP OR 2' LAMP








plaster ceiling/flanged.
drywall kit. (See options)


Job Name:
Cat. No.:
Drywall Kit (See Options)
1-1/8" min. 3-3/4" max.
Lamp(s):
Volts/Ballast:
15/16" Ceiling Opening 24-5/16" x 24-5/16"

Page 2 of 2 2'x2' RECESSED FLUORESCENT, 11/2" DEEP, 36 CELL PARABOLIC LOUVER, STATIC OR AIR SUPPLY/RETURN, 2 OR 3 LAMP, T8, 1-5/8"U LAMP OR 2' LAMP
Luminaire Efficacy Rating LER-50.8 Watts-77.6 BF-0.88

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 61 59 57 56 54 53 54 53 52 2 57 53 50 50 48 46 49 47 45 3 53 48 44 45 43 40 44 42 40 4 49 43 39 41 38 35 40 37 35 5 45 39 35 37 34 31 36 33 31 6 42 35 31 34 30 28 33 30 27 7 39 32 28 31 27 25 30 27 25 8 36 30 25 29 25 22 28 25 22 9 34 27 23 26 23 20 26 23 20 10 32 25 21 25 21 19 24 21 18 visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 77 70 62 67 77 69 62 65 20 30 79 73 67 62 79 72 66 62 20 40 82 76 71 65 81 75 70 65 20 60 83 78 73 69 83 77 72 68 30 20 81 75 65 66 81 74 65 65 30 30 83 77 69 61 83 76 68 62 30 40 85 79 72 65 85 78 71 65 30 60 86 81 75 68 86 80 74 68 30 80 87 82 77 71 87 82 76 70 40 20 83 77 69 68 82 77 69 66 40 30 85 80 73 63 84 79 72 63 40 40 86 81 75 67 86 81 75 66 40 60 87 83 77 69 87 82 77 69 40 80 88 84 79 72 88 84 79 71 40 100 88 85 81 74 88 84 80 73 60 30 85 81 75 67 85 80 74 67 60 40 87 82 77 70 87 82 77 69 60 60 88 84 79 72 88 83 79 71 60 80 88 85 81 74 88 85 80 74 60 100 89 86 82 76 89 85 82 75 100 40 87 82 79 71 87 82 78 71 100 60 88 84 81 74 88 84 80 73 100 80 88 85 82 76 89 85 82 76 100 100 89 86 83 78 89 85 83 77
MP
(lay-in T bar) F=Flanged
2=2 Lamp 3=3 Lamp LAMP TYPE/ FIXTURE LENGTH: 2U=T8, 1-5/8"U Lamp 17=T8, 2' Lamp (Nominal 48")
NUMBER OF
Iridescence Semi-specular (standard) P= Low
CELLS
Z spline and plaster frame T=Slot grid or
Reflector (3 Lamp) S=Single “V”
Iridescence Specular W=White Baked
two-directional concealed T (see options)
Other dimming options. Consult factory.
OPTIONS/ACCESSORIES PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUF- FIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX: ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS: PERFORMANCE: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .59. To prevent glare the VCP shall be not less than 71 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1338 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 62.7%. AIR HANDLING (MPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends. MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity– white baked poly-
ester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low irides- cence semi-specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W. UL and ULc Listed.
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。