Page 1 of 2 2'x2' RECESSED FLUORESCENT, 1 1/2" DEEP, 36 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 2-6"U LAMP, T8 OR T12

G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.
Air supply slots (MPA only)

15/16" or 1" 24"
concealed Z-spline ceiling.
direct concealed two directional T-grid ceiling (see options for


splay trim).
1/4" max.
1-7/8" max. 1-1/8" min. 3-3/4" max.
2"x 2 1/2" access plate with two K.O.s (7/8" dia.)
F
plaster ceiling/flanged.
drywall kit. (See options)


Job Name:
Cat. No.:
Drywall Kit (See Options)
Lamp(s):
1-1/8" min. 3-3/4" max.
Volts/Ballast:
15/16" Ceiling Opening 24-5/16" x 24-5/16"

Page 2 of 2 2'x2' RECESSED FLUORESCENT, 1 1/2" DEEP, 36 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 2-6"U LAMP, T8 OR T12
Luminaire Efficacy Rating LER-52.3 Watts-57.3 BF-0.87

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 65 63 61 59 58 56 57 56 55 2 60 56 53 53 51 49 51 49 48 3 56 51 47 48 45 42 46 44 42 4 51 45 41 43 40 37 42 39 37 5 48 41 37 39 36 33 38 35 32 6 44 37 33 36 32 29 35 31 29 7 41 34 29 33 29 26 32 28 26 8 38 31 27 30 26 23 29 26 23 9 36 29 24 28 24 21 27 24 21 10 34 27 22 26 22 19 25 22 19 visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 79 73 66 73 77 70 63 68 20 30 82 76 70 66 80 73 67 63 20 40 83 78 74 70 82 76 71 66 20 60 85 80 76 73 83 78 74 69 30 20 83 77 68 71 80 75 66 68 30 30 85 80 72 66 83 78 69 64 30 40 86 81 75 69 85 80 73 67 30 60 87 83 77 72 86 82 75 69 30 80 88 84 79 74 87 83 77 72 40 20 83 80 72 72 80 77 71 69 40 30 86 82 75 67 84 80 73 66 40 40 87 84 78 70 86 82 76 68 40 60 88 85 80 73 87 83 78 71 40 80 89 86 81 75 88 85 80 73 40 100 89 86 83 77 89 86 81 75 60 30 86 82 77 70 84 80 75 69 60 40 87 84 80 73 86 82 78 71 60 60 88 85 81 75 87 84 80 74 60 80 89 86 83 77 88 85 82 76 60 100 89 86 84 79 89 86 82 77 100 40 87 84 80 74 86 82 78 72 100 60 88 85 82 77 87 84 80 75 100 80 89 87 83 79 88 86 82 77 100 100 90 87 84 80 89 87 82 79
MP
S
6U
VOLTAGE:
(lay-in T bar) F=Flanged
NUMBER OF
Iridescence Semi-specular (standard) P= Low
CELLS
SINGLE “V” REFLECTOR
FIXTURE LENGTH:
Z spline and plaster frame T=Slot grid or
BALLAST TYPE: 1-2 Lamp Mag. T12 LE
6"U Lamp T8 or T12 (Nominal 24")
Iridescence Specular W=White Baked
two-directional concealed T (see options)
OPTIONS & ACCESSORIES PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX: ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity– white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W. UL and ULc Listed.
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .63. To prevent glare the VCP shall be not less than 80 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1089 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 63.2%. AIR HANDLING (MPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.