
Page 1 of 2 2'x4' RECESSED FLUORESCENT, 1 1/2" DEEP, 78 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 4 LAMP, T8 OR T12

G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.

6" (152mm) Air supply slots (MPA only)
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)
15/16" or 1" 24"
concealed Z-spline ceiling.
direct concealed two directional T-grid ceiling (see options for


splay trim).
1/4" max.
1-7/8" max. 1-1/8" min. 3-3/4" max.
F
plaster ceiling/flanged.
drywall kit. (See options)


Job Name:
Cat. No.:
Drywall Kit (See Options)
Lamp(s):
1-1/8" min. 3-3/4" max.
Volts/Ballast:
15/16" Ceiling Opening 24-5/16" x 48-5/16"

Page 2 of 2 2'x4' RECESSED FLUORESCENT, 1 1/2" DEEP, 78 CELL PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, 4 LAMP, T8 OR T12
Luminaire Efficacy Rating LER-54.8 Watts-116.2 BF-0.86
coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 69 67 65 63 62 60 61 59 58 2 64 60 57 57 54 52 55 53 51 3 59 54 50 51 48 45 50 47 44 4 55 48 44 46 42 39 45 41 39 5 51 44 39 42 38 35 41 37 34 6 47 40 35 38 34 31 37 33 30 7 44 36 31 35 30 27 34 30 27 8 41 33 28 32 28 25 31 27 24 9 38 30 26 29 25 22 29 25 22 10 36 28 23 27 23 20 27 23 20 visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 84 78 72 77 82 75 67 73 20 30 86 81 76 73 82 79 72 67 20 40 86 81 80 76 82 79 76 71 20 60 86 82 80 79 82 79 76 75 30 20 85 82 73 75 82 80 70 73 30 30 86 85 77 71 82 83 74 67 30 40 86 85 81 75 82 83 78 71 30 60 86 85 81 78 83 83 78 75 30 80 86 85 81 78 83 83 78 75 40 20 85 82 75 76 82 80 72 74 40 30 86 85 80 72 82 83 77 69 40 40 86 85 82 76 83 83 80 73 40 60 87 85 82 79 83 83 80 76 40 80 87 85 82 79 83 83 80 76 40 100 87 85 82 79 83 83 80 76 60 30 86 85 80 75 83 83 77 73 60 40 86 85 82 78 83 83 80 76 60 60 87 85 82 81 83 83 80 77 60 80 87 85 82 80 83 83 80 78 60 100 87 85 82 80 83 83 80 77 100 40 87 85 82 78 83 83 80 76 100 60 87 85 82 80 83 83 80 77 100 80 87 85 82 80 83 83 80 77 100 100 87 85 82 80 83 83 80 77
MP
S
(lay-in T bar) F=Flanged
Iridescence Semi-specular (standard) P= Low
NUMBER OF
SINGLE REFLECTOR
LAMP TYPE/
WIDTH
Z spline and plaster frame T=Slot grid or
FIXTURE LENGTH:
BALLAST TYPE: 2-2 Lamp Mag. T12 LE
Iridescence Specular W=White Baked
32=T8 34=T12 (Nominal 48")
two-directional concealed T (see options)
OPTIONS & ACCESSORIES PLASTER FRAME: Catalog Number: PF24. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX: ACS4 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X4. (Request Folio OA30-10) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity– white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W. UL and ULc Listed.
SPECIFICATIONS PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67. To prevent glare the VCP shall be not less than 80 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1098 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 64.8%. AIR HANDLING (MPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。