Page 1 of 2 4 1/2" Aperture A19

3/4" max. Ceiling Thickness 4 5/16" Dia. Overlap 5-3/4" Flush 5"
Molded Trim Ring Flush Trim (Molded Trim Ring Removed)
Overlap Self-Flange Matte White or Polished
Ceiling Cutout: 5 1/6” Dia.

Features 1. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Contains medium base porcelain socket with nickel plated screw shell wired with No. 18 SF1 leads to J-Box. 2. Mounting Bracket: Adjusts vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4” or 1 1/2” lathing channels, or 1/2” (11/16" O.D.) EMT pipe (by others), or Lightolier accessory mounting bars. 3. Retaining Springs: Precision tooled springs secure reflector to mounting frame for quick tool-less installation. 4. Insert reflector: Alzak® aluminum, 16 ga., “cut-window” reflector allows light to pass to a separately contoured outer housing reflector. 50° visual cut-off to lamp and lamp image. Insert reflector contours provide even down- lighting. Direction of wall wash can be re-orientated after installation. Attached with thumb screws for simple installation and maintenance. Reflector supplied with white molded trim ring (field paintable); or self- flanged reflector, matte white or flange finish to match reflector. 5. Junction Box: 14 ga. steel, 4" x 4” x 2" specially designed horizontal junc- tion box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements.Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. Provides flangeless trim in plaster ceiling.
Options & Accessories (continued) Wood Joist Mtg. Bars 7994 (set of 2) Existing Ceiling Clips 7998 (set of 2) Step Down Transformer 7997 see separate specification sheet Chicago Air Plenum LC (add suffix to Frame-in Kit. Requires access
Electrical UL Listed for a maximum of 8 No. 12, 75°C through branch circuit conductors, or 60°C supply conductors for end of run.
Labels UL Listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.

Options & Accessories 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars)

Page 2 of 2 4 1/2" Aperture A19

Example: with multiple clear cone units, using 100W A-19 lamps, located 2' from wall and 4' on cen- ter, (matching downlights 4' on center), the illumina- tion on the wall 3' down from the ceiling is 14 f.c. beneath fixtures and 12 f.c. between fixtures.
Units 2 Feet From Wall
1 19 18 19 15 14 15 15 8 15
Distance from Ceiling (FT.) Distance from Ceiling (FT.)
2 26 26 26 20 20 20 18 15 18
3 22 22 22 16 16 16 14 12 14
4 16 18 16 12 14 12 10 10 10
5 13 14 13 10 12 10 9 8 9
6 13 12 13 9 10 9 9 8 9
7 10 10 10 8 6 8
8 10 10 10 8 6 8
9 10 10 10 8 6 8
Units 3 Feet From Wall
3' 4' 5' 6'
1 7 10 7 7 6 7 5 4 5 5 3 3
2 13 12 13 11 8 11 9 8 9 9 6 9
3 14 14 14 12 10 12 8
4 13 14 13 11 8 11 8 8 8 7 8 7
5 10 14 10 10 8 10 8 8 8 6 6 6
6 9 12 9 9 6 9 7 6 7 5 6 5
7 9 12 9 9 6 9 7 6 7 5 6 5
8 9 10 9 9 6 9 7 6 7 5 6 5
9 9 10 9 9 6 9 7 6 7 5 6 5
Footcandle values are averaged and rounded off and are based on a minimum of five units. Conversion factors: 75W A-19 (Clear) = F.C. x 0.7; 75W A-19 (Gold) = F.C. x 0.6; 100W A-19 (Gold) = F.C. x 0.9;
Coefficients of Utilization % Effective Ceiling Cavity Reflectance
1 2 3 4 5 6 7 8 9 10
.62 .60 .59 .58 .57 .56 .54 .53 .53 .58 .55 .53 .55 .53 .52 .51 .50 .49 .54 .51 .49 .51 .49 .48 .49 .48 .47 .50 .48 .46 .48 .47 .45 .47 .45 .44 .48 .44 .42 .46 .43 .41 .44 .42 .41 .44 .41 .39 .43 .40 .38 .41 .39 .39 .41 .38 .35 .40 .37 .35 .39 .36 .34 .38 .35 .32 .37 .34 .32 .36 .33 .32 .35 .31 .29 .34 .31 .29 .33 .31 .29 .32 .29 .27 .32 .29 .27 .31 .29 .27
For even wall washing use a maximum of 2 to 1 spacing (distance between fixture + distance to wall).
20% Floor Cavity Reflectance
Ratio = 1.3
Conversion Factors: 75W A-19; (Clear): C.U. X 1.O. 75W (Gold): C.U. X 0.9. 100W A-19 (Gold): C.U. X 0.9