Calculite ® ProSpec ® Linear Downlight PA4A7050

Page 1 of 2 4 Light AR 70 Series A

Top View

Lightolier PA4A7050 — Top View diagram (page 1)
図 1 · Top View

Ceiling Cutout: 21 1/16" L x 6 3/16" W

Ordering InformationAR 70 Series A Cat. No. Lamp Ceiling Trim Aperture Finish

PA4A7050BL (4) 50W AR 70 Overlap Black with White Flange PA4A7050WL (4) 50W AR 70 Overlap White with White Flange PA4A7050BTL (4) 50W AR 70 Trimles Black PA4A7050WTL (4) 50W AR 70 Trimles White

Features 1. Aperture Frame: Provides clean support for lamp holders and overlapping flange or trimless installation. Extruded aluminum. Rigidly welded together on all corners. 2. Media Cartridge: Allows convenient loading and removal of up to two accessories (including lamp cover glass; lamp cover glass may be replaced with solid glass accessory). Easily installed and removed for lamping with a simple twisting motion. Constructed of die-cast aluminum. 3. Cross Blade Louver: Extruded aluminum. 1" deep, provides additional shielding and can be easily removed. 4. Adjustable Ring: Allows 360° horizontal and 35° (on width) and 45° (on length) vertical adjustment. 5. Tortiontite Spring: For easy installation of aperture frame. 6. Housing: Die-formed 22 ga. steel. Finish: Black. 7. Mounting Brackets: Adjustable vertically from outside of housing. 8. Thermal Protector: Meets NEC, UL , and CSA requirements. 9. Lampholder: double contact bayonet base with 250°C #18 gauge Teflon®

Electrical (continued) UL/cUL listed for through branch circuit wiring with maximum of (8) no. 12 AWG, 90°C.

Finish All painted finishes are powder coated baked enamel.

Options & Accessories Accessories: 2 1/2" dia. series, filters, lenses, screens and louvers. (2) accessories maximum, including lamp cover glass. Lamp guard glass may be replaced with solid glass accessory.

Labels UL/cUL (Suitable for Damp Location), I.B.E.W.

Teflon® is a registered trademark of E.I. DuPont. US Patent Pending.

leads. 10.Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box. Allows inspection from below. 11.Lamp and Accessory Support: .032" steel, flared for easy entry of Media Cartridge. 12.Lens Retaining Ring: .093" spring steel rod. Holds accessories in place. 13.Lamp Guard: Heat-resistant clear glass. Lamp manufacturers requirement. 14.Transformer Housing: Die-formed 18 ga. steel.

Lightolier PA4A7050 — Ceiling Cutout: 21 1/16" L x 6 3/16" W diagram (page 1)
図 2 · Ceiling Cutout: 21 1/16" L x 6 3/16" W

Electrical Magnetic Transformer: Individual for each lamp. Offers reliable operation and is accessible from below for servicing. 120V Primary; 11.5V Secondary.

Dimming Controls: Use only dimmers specifically designed for use with magnetic transformers, like Lightolier Onset series LV or VA dimmers, or any Lightolier Control dimming system. Low Voltage fixtures may produce audible sound when used with dimmers, which may be objectionable in acoustically critical areas.

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902
Page 2 of the Lightolier PA4A7050 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® ProSpec ® Linear Downlight PA4A7050

Page 2 of 2 4 Light AR 70 Series A

Lighting Performance Data

Aiming Angle0° 30° 45° or 60° Horizontal 30° 45° or 60° Vertical

L Beam length B Beam width C Distance to center of beam D Distance A Aiming angle FC Foot candles

Lightolier PA4A7050 — Calculite ® ProSpec ® Linear Downlight PA4A7050 diagram (page 2)
図 3 · Calculite ® ProSpec ® Linear Downlight PA4A7050

Lamp data shown is typical, and is based on bare lamp photometrics. Contact lamp manufacturers for availability and performance.

Lamp 0° Aiming Angle 30° Aiming Angle 45° Aiming Angle 60° Aiming Angle

D FC L W D C FC L W D C FC L W D C FC L W Lamps Beam Spread CBCP Rated (To 50% CBCP) Life (Hrs.)

5’ 5.0’ 212 1.8’ 1.2’ 7’ 7.0’ 108 2.5’ 1.7’ 9’ 9.0’ 65 3.2’ 2.2’ 11’ 11.0’ 44 3.9’ 2.7’ 15000 2000 50W AR70 SP (T-H) 10°

8’ 234 1.4’ 1.4’ 12’ 104 2.1’ 2.1’ 16’ 59 2.8’ 2.8’ 20’ 38 3.5’ 3.5’

7’ 4.0’ 199 1.6’ 1.4’ 10’ 5.8’ 97 2.3’ 2.0’ 13’ 7.5’ 58 3.0’ 2.6’ 16’ 9.2’ 38 3.7’ 3.2’

3’ 5.2’ 208 2.1’ 1.0’ 4’ 6.9’ 117 2.9’ 1.4’ 5’ 8.7’ 75 3.6’ 1.7’ 6’ 10.4’ 52 4.3’ 2.1’

3’ 1.7’ 144 2.2’ 1.9’ 5’ 2.9’ 52 3.7’ 3.1’ 7’ 4.0’ 27 5.1’ 4.3’ 9’ 5.2’ 16 6.6’ 5.6’

1’ 1.7’ 250 2.7’ 1.1’ 2’ 3.5’ 63 5.5’ 2.1’ 3’ 5.2’ 28 8.2’ 3.2’ 4’ 6.9’ 16 10.9’ 4.3’

3’ 3.0’ 79 3.5’ 2.3’ 4’ 4.0’ 44 4.6’ 3.0’ 5’ 5.0’ 28 5.8’ 3.8’ 6’ 6.0’ 20 6.9’ 4.5’ 2000 2000 50W AR70 FL (T-H) 30°

4’ 125 2.1’ 2.1’’ 6’ 56 3.2’ 3.2’ 8’ 31 4.3’ 4.3’ 10’ 20 5.4’ 5.4’

5’ 5.0’ 191 1.8’ 1.2’ 7’ 7.0’ 97 2.5’ 1.7’ 9’ 9.0’ 59 3.2’ 2.2’ 11’ 11.0’ 39 3.9’ 2.7’ 13500 2000 50W AR70 SP GOLD (T-H) 10°

8’ 211 1.4’ 1.4’ 12’ 94 2.1’ 2.1’ 16’ 53 2.8’ 2.8’ 20’ 34 3.5’ 3.5’

7’ 4.0’ 199 1.6’ 1.4’ 10’ 5.8’ 97 2.3’ 2.0’ 13’ 7.5’ 58 3.0’ 2.6’ 16’ 9.2’ 38 3.7’ 3.2’

3’ 5.2’ 188 2.1’ 1.0’ 4’ 6.9’ 105 2.9’ 1.4’ 5’ 8.7’ 68 3.6’ 1.7’ 6’ 10.4’ 47 4.3’ 2.1’

3’ 3.0’ 71 3.5’ 2.3’ 4’ 4.0’ 40 4.6’ 3.0’ 5’ 5.0’ 25 5.8’ 3.8’ 6’ 6.0’ 18 6.9’ 4.5’ 1800 2000 50W AR70 FL GOLD (T-H) 30°

4’ 125 2.1’ 2.1’’ 6’ 56 3.2’ 3.2’ 8’ 31 4.3’ 4.3’ 10’ 20 5.4’ 5.4’

3’ 1.7’ 144 2.2’ 1.9’ 5’ 2.9’ 52 3.7’ 3.1’ 7’ 4.0’ 27 5.1’ 4.3’ 9’ 5.2’ 16 6.6’ 5.6’

1’ 1.7’ 225 2.7’ 1.1’ 2’ 3.5’ 56 5.5’ 2.1’ 3’ 5.2’ 25 8.2’ 3.2’ 4’ 6.9’ 14 10.9’ 4.3’

5’ 8.7’ 250 1.8’ 0.9’ 8’ 13.9’ 98 2.6’ 1.4’ 11’ 19.1’ 52 3.9’ 1.9’ 14’ 24.2’ 32 4.9’ 2.4’ 50000 2000 50W AR111 NSP (T-H) 5°

15’ 222 1.3’ 1.3’ 20’ 125 1.7’ 1.7’ 25’ 80 2.2’ 2.2’ 30’ 56 2.6’ 2.6’

10’ 5.8’ 325 1.2’ 1.0’ 15’ 8.7’ 144 1.7’ 1.5’ 20’ 11.5’ 81 2.3’ 2.0’ 25’ 14.4’ 52 2.9’ 2.5’

8’ 8.0’ 276 1.4’ 1.0’ 12’ 12.0’ 123 2.1’ 1.5’ 16’ 16.0’ 69 2.8’ 2.0’ 20’ 20.0’ 44 3.5’ 2.5’

2’ 3.5’ 94 5.5’ 2.1’ 3’ 5.2’ 42 8.2’ 3.2’ 4’ 6.9’ 23 10.9’ 4.3’ 5’ 8.7’ 15 13.7’ 5.4’ 3000 2000 50W AR111 FL (T-H) 30°

6’ 83 3.2’ 3.2’ 8’ 47 4.3’ 4.3’ 10’ 30 5.4’ 5.4’ 12’ 21 6.4’ 6.4’

5’ 2.9’ 78 3.7’ 3.1’ 7’ 4.0’ 40 5.1’ 4.3’ 9’ 5.2’ 24 6.6’ 5.6’ 11’ 6.4’ 16 8.1’ 6.6’

3’ 3.0’ 118 3.5’ 2.3’ 5’ 5.0’ 42 5.8’ 3.6’ 7’ 7.0’ 22 8.1’ 5.3’ 9’ 9.0’ 13 10.4’ 6.8’

Data are based on bare lamp photometrics. Dashed lines in beam spreads indicate narrow axes of oval shaped beams. FC is initial footcandles at center of beam. L and W are to the point that the candlepower drops 50% of maximum.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier PA4A7050について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier PA4A7050に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier PA4A7050 取扱説明書(PDF)

2 ページ·87 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…