PB2A7050
Page 1 of 2 2 Light AR 70 Series B
13" 8" 7 9

Flanged Trimless
Add a “1” for 120v or “2” for 277v at the end of the catalog number for voltage
PB2A705EBL (2) 50W AR 70 Overlap Black with White Flange PB2A705EWL (2) 50W AR 70 Overlap White with White Flange PB2A705EBTL (2) 50W AR 70 Trimless Black PB2A705EWTL (2) 50W AR 70 Trimless White
Features 1. Aperture Frame: Provides clean support for lamp holders and overlapping flange or trimless installation. Extruded aluminum. Rigidly welded together on all corners. 2. Media Cartridge: Allows convenient loading and removal of up to one accessory. Easily installed and removed for lamping with a simple twisting motion. Constructed of formed aluminum. 3. Adjustable Ring: Allows 360° horizontal and 45° (on width) and 45° (on length) vertical adjustment. 4. Tortiontite Spring: For easy installation of aperture frame. 5. Housing: Die-formed 22 ga. steel. Finish: Black. 6. Mounting Brackets: Adjustable vertically from outside of housing. 7. Thermal Protector: Meets NEC, UL , and CSA requirements. 8. Lampholder: Double contact bayonet base with 250°C #18 gauge Teflon®
Finish All painted finishes are powder coated baked enamel.
Options & Accessories Accessories: 2 1/2" dia. series, filters, lenses, screens and louvers. (2) accessories maximum, including lamp cover glass. Lamp guard glass may be replaced with solid glass accessory.
Labels UL/cUL (Suitable for Damp Location), I.B.E.W.
leads. 9. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box. Allows inspection from below. 10.Lamp and Accessory Support:.032" steel, flared for easy entry of Media Cartridge. 11.Lens Retaining Ring:.093" spring steel rod. Holds accessories in place. 12.Lamp Guard: Heat-resistant clear glass. Lamp manufacturers requirement. 13.Transformer Housing: Die-formed 18 ga. steel.
Teflon® is a registered trademark of E.I. DuPont. US Patent Pending.

Electrical Electronic Transformers: Offer reliable operation and are accessible from below for servicing. 12V. Secondary 50 VA. each lamp.
Dimming Controls: Use only dimmers specifically designed for use with electronic transformers. Low Voltage fixtures may produce audible sound when used with dimmers, which may be objectionable in acoustically critical areas.
UL/cUL listed for through branch circuit wiring with maximum of (8) no. 12 AWG, 90°C.
20 1/8" · 17"

Aiming Angle 0° 30° 45° or 60° Horizontal 30° 45° or 60° Vertical
L Beam length B Beam width C Distance to center of beam D Distance A Aiming angle FC Foot candles
Lamp data shown is typical, and is based on bare lamp photometrics. Contact lamp manufacturers for availability and performance.
LAMP 0° Aiming Angle 30° Aiming Angle 45° Aiming Angle 60° Aiming Angle
D FC L W D C FC L W D C FC L W D C FC L W Lamps Beam Spread CBCP Rated (To 50% CBCP) Life (Hrs.)
8’ 234 1.4’ 1.4’ 12’ 104 2.1’ 2.1’ 16’ 59 2.8’ 2.8’ 20’ 38 3.5’ 3.5’
7’ 4.0’ 199 1.6’ 1.4’ 10’ 5.8’ 97 2.3’ 2.0’ 13’ 7.5’ 58 3.0’ 2.6’ 16’ 9.2’ 38 3.7’ 3.2’
3’ 5.2’ 208 2.1’ 1.0’ 4’ 6.9’ 117 2.9’ 1.4’ 5’ 8.7’ 75 3.6’ 1.7’ 6’ 10.4’ 52 4.3’ 2.1’
4’ 125 2.1’ 2.1’’ 6’ 56 3.2’ 3.2’ 8’ 31 4.3’ 4.3’ 10’ 20 5.4’ 5.4’
3’ 1.7’ 144 2.2’ 1.9’ 5’ 2.9’ 52 3.7’ 3.1’ 7’ 4.0’ 27 5.1’ 4.3’ 9’ 5.2’ 16 6.6’ 5.6’
1’ 1.7’ 250 2.7’ 1.1’ 2’ 3.5’ 63 5.5’ 2.1’ 3’ 5.2’ 28 8.2’ 3.2’ 4’ 6.9’ 16 10.9’ 4.3’
8’ 211 1.4’ 1.4’ 12’ 94 2.1’ 2.1’ 16’ 53 2.8’ 2.8’ 20’ 34 3.5’ 3.5’
7’ 4.0’ 199 1.6’ 1.4’ 10’ 5.8’ 97 2.3’ 2.0’ 13’ 7.5’ 58 3.0’ 2.6’ 16’ 9.2’ 38 3.7’ 3.2’
3’ 5.2’ 188 2.1’ 1.0’ 4’ 6.9’ 105 2.9’ 1.4’ 5’ 8.7’ 68 3.6’ 1.7’ 6’ 10.4’ 47 4.3’ 2.1’
4’ 125 2.1’ 2.1’’ 6’ 56 3.2’ 3.2’ 8’ 31 4.3’ 4.3’ 10’ 20 5.4’ 5.4’
3’ 1.7’ 144 2.2’ 1.9’ 5’ 2.9’ 52 3.7’ 3.1’ 7’ 4.0’ 27 5.1’ 4.3’ 9’ 5.2’ 16 6.6’ 5.6’
1’ 1.7’ 225 2.7’ 1.1’ 2’ 3.5’ 56 5.5’ 2.1’ 3’ 5.2’ 25 8.2’ 3.2’ 4’ 6.9’ 14 10.9’ 4.3’
15’ 222 1.3’ 1.3’ 20’ 125 1.7’ 1.7’ 25’ 80 2.2’ 2.2’ 30’ 56 2.6’ 2.6’
10’ 5.8’ 325 1.2’ 1.0’ 15’ 8.7’ 144 1.7’ 1.5’ 20’ 11.5’ 81 2.3’ 2.0’ 25’ 14.4’ 52 2.9’ 2.5’
8’ 8.0’ 276 1.4’ 1.0’ 12’ 12.0’ 123 2.1’ 1.5’ 16’ 16.0’ 69 2.8’ 2.0’ 20’ 20.0’ 44 3.5’ 2.5’
6’ 83 3.2’ 3.2’ 8’ 47 4.3’ 4.3’ 10’ 30 5.4’ 5.4’ 12’ 21 6.4’ 6.4’
5’ 2.9’ 78 3.7’ 3.1’ 7’ 4.0’ 40 5.1’ 4.3’ 9’ 5.2’ 24 6.6’ 5.6’ 11’ 6.4’ 16 8.1’ 6.6’
3’ 3.0’ 118 3.5’ 2.3’ 5’ 5.0’ 42 5.8’ 3.6’ 7’ 7.0’ 22 8.1’ 5.3’ 9’ 9.0’ 13 10.4’ 6.8’
Data are based on bare lamp photometrics. Dashed lines in beam spreads indicate narrow axes of oval shaped beams. FC is initial footcandles at center of beam. L and W are to the point that the candlepower drops 50% of maximum.