Visual comfort combined with the benefits of careful detailing, easy installation, and affordability.
Lightolier’s PerfLyte luminaire features a streamlined elliptical profile with an elegant perforated housing in two sizes and four distinctive diffuser styles. PerfLyte offers high quality lighting in an array of lighting distributions. Its visual comfort combined with the benefits of careful detailing, easy installation, product range and affordability make a great choice for refined commercial applications. PerfLyte’s simple modular approach enables you to create uninterrupted continuous runs of any length.

Joining Capabilities
The careful detailing of the regressed steel die-formed end cap creates strength and a lighter appearance.
PerfLyte’s modular sections are easily joined end-to-end to create continuous runs.


631 Airport Road Fall River, MA 02720 Phone (508) 679-8131 Fax (508) 674-4710 www.lightolier.com

Lightolier C.F.I. A Division of Canlyte 525 Educational Road Cornwall, Ontario Canada K6H 6C7 Phone (613) 938-6221
Lighting Application
PerfLyte’s Optical Systems offer superior performance. The light distribution ratios range from approximately 100%/0% to 60%/40%.
PerfLyte can be used in a range of commercial and institu- tional applications: open and individual offices, conference rooms, reception areas, libraries, health care facilities, and classrooms. Contractor Friendly
© 2000 Lightolier, a Division of Genlyte Thomas Group LLC. All rights reserved. Certain products illustrated in this catalog may be protected by applicable patents and patents pending. Lightolier will aggressively defend all of its intellectual property. We reserve the right to change details of design, materials and finishes.
Our simplified mounting system allows you to position feed and support locations on or off the ceiling grid in a fraction of the time, minimizing labor costs. See page 6 for details. Affordable
A.I.A. Division 16 Brochure 29128

PerfLyte is affordably priced to fit limited budget projects.
Printed in the U.S.A.

™ · (under flap)

PerfLyte 13"
Easy to install
How to order
LP2A: 13" Solid Indirect
PerfLyte 9" PerfLyte 13"
Application Data
Coefficients of Utilization
Application Data
9" Solid Indirect
13" Solid Indirect
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
Style Series Type Lamps Length Ballast Options
2.5" (63.5 mm) 2.5"
0 82 82 82 1 71 68 65 2 62 57 53 3 54 49 44 4 48 42 37 5 42 36 31 6 37 31 26 7 33 27 23 8 30 24 20 9 27 21 17
50' x 70' Space 10' 9' 18" 76 179 6.7 1.7 12' 10.5' 24" 62 134 5.6 1.4
0 84 84 84 1 73 69 67 2 63 59 54 3 56 50 45 4 49 43 38 5 43 37 32 6 38 32 27 7 34 28 23 8 31 25 20 9 28 22 18 10 25 20 16
50' x 70' Space 10' 9' 18" 78 188 6.4 1.7 12' 10.5' 24" 64 142 5.5 1.4
LP 2 A
Luminaire Row Spacing Luminaire Row Spacing Luminaire Row Spacing
Luminaire Row Spacing Luminaire Row Spacing Luminaire Row Spacing
9" (228.6 mm)
2T8=2 lamp T8 4 = 4 foot U = Uni-Voltage Blank = no options 3T8=3 lamp T8 8 = 8 foot E = Emergency DS = Dual Switch 12=12foot Pack X4 = 4 wire for Dim D1 = Dim 120v & Switched D2 = Dim 277v Emg
2T8=2 lamp T8 4 = 4 foot U = Uni-Voltage Blank = no options 3T8=3 lamp T8 8 = 8 foot E = Emergency DS = Dual Switch Pack X4 = 4 wire for Dim D1 = Dim 120v & Switched D2 = Dim 277v Emg
LPL1A2T8: 2 lamp T8 85.7% efficiency, 100% ∧0% ∨ LPL1A3T8: 3 lamp T8 84.3% efficiency, 100% ∧0% ∨
LPL2A2T8: 2 lamp T8 87.8% efficiency, 100% ∧0% ∨ LPL2A3T8: 3 lamp T8 87.6% efficiency, 100% ∧0% ∨
12' x 16' Space 8' 9' 18" 72 176 4.9 2.1
12' x 16' Space 8' 9' 18" 75 185 4.9 2.1
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 72 132 6.0 1.4
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 75 140 5.9 1.4
Report No. LRL 300-1X
All performance data shown are for 2 lamp T8. For other lamping options and complete performance data please refer to specifica- tion sheets.
Report No. LRL 300-1Y
All performance data shown are for 2 lamp T8. For other lamping options and complete performance data please refer to specifica- tion sheets.
10 25 19 15 80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
13" Semi Perforated
Style Series Type Lamps Length Ballast Options
LP1B: 9" Semi-Perforated Luminous Indirect
LP2B: 13" Semi-Perforated Luminous Indirect
Coefficients of Utilization
Application Data
Coefficients of Utilization
Application Data
LP 1 B
LP 2 B
2T8=2 lamp T8 4 = 4 foot U = Uni-Voltage Blank = no options 3T8=3 lamp T8 8 = 8 foot E = Emergency DS = Dual Switch 2T5=2 lamp T5 12=12foot Pack X4 = 4 wire forDim 3T5=3 lamp T5 D1 = Dim 120v & Switched 2HO=2 lamp T5 D2 = Dim 277v Emg 3HO=3 lamp T5
2T8=2 lamp T8 4 = 4 foot U = Uni-Voltage Blank = no options 3T8=3 lamp T8 8 = 8 foot E = Emergency DS = Dual Switch 4T8 =4 lamp T8 Pack X4 = 4 wire forDim 2BX=2 lamp Biax D1 = Dim 120v & Switched D2 = Dim 277v Emg
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
2.5"
3.4"
0 76 76 76 1 66 63 60 2 57 53 49 3 50 45 41 4 44 39 34 5 39 33 29 6 35 29 25 7 31 26 22 8 28 23 19 9 26 20 16 10 23 18 14
50' x 70' Space 10' 9' 18" 71 135 5.2 1.5 12' 10.5' 24" 58 100 4.3 1.3
0 82 82 82 1 71 68 65 2 62 58 54 3 55 49 44 4 48 42 37 5 43 36 32 6 38 32 27 7 34 28 23 8 30 24 20 9 28 22 18 10 25 19 16
50' x 70' Space 10' 9' 18" 76 215 5.4 2.4 12' 10.5' 24" 94 159 4.6 2.0
LPL1B2T8: 2 lamp T8 77.7% efficiency, 91.1% ∧8.9% ∨ LPL1B3T8: 3 lamp T8 75.7% efficiency, 92.0% ∧8.0% ∨ LPL1B2T5: 2 lamp T5 28W 74.9% efficiency, 91.3% ∧8.7% ∨ LPL1B3T5: 3 lamp T5 28W 76.9% efficiency, 93.1% ∧6.9% ∨
LPL2B2T8: 2 lamp T8 81.3% efficiency, 91.3% ∧8.7% ∨ LPL2B3T8: 3 lamp T8 85.0% efficiency, 93.1% ∧6.9% ∨ LPL2B4T8: 4 lamp T8 80.7% efficiency, 91.9% ∧8.1% ∨ LPL2BX: 2 lamp Biax 77.7% efficiency, 93.1% ∧6.9% ∨
12' x 16' Space 8' 9' 18" 67 133 3.8 1.9
12' x 16' Space 8' 9' 18" 111 212 4.2 3.0
13" Fully Perforated
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 45 98 4.6 1.3
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 74 156 4.9 2.0
Report No. LRL 200-10B
Style Series Type Lamps Length Ballast Options
Report No. LRL 200-10H
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
All performance data shown are for 3 lamp T8. For other lamping options and complete performance data please refer to specifica- tion sheets.
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
All performance data shown are for 2 lamp T8. For other lamping options and complete performance data please refer to specifica- tion sheets.
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
LP 2 C
4 = 4 foot U = Uni-Voltage Blank = no options 8 = 8 foot E = Emergency DS = Dual Switch 12=12foot Pack X4 = 4 wire forDim D1 = Dim 120v & Switched D2 = Dim 277v Emg
2T8=2 lamp T8 4 = 4 foot U = Uni-Voltage Blank = no options 2BX=2 lamp 8 = 8 foot E = Emergency DS = Dual Switch Biax Pack X4 = 4 wire forDim D1 = Dim 120v & Switched D2 = Dim 277v Emg
LP1C: 9” Fully Perforated Indirect/Direct
Application Data
PerfLyte 9" Cable Assembly – aircraft cable adjustable up to 36" Single Cable: LP1C36 Single Cable and Cord: LP1CC36 Single Cable and 4 Wire Cord: LP1CC36X4
PerfLyte 13" Cable Assembly – aircraft cable adjustable up to 36" Single Cable: LP2C36 Single Cable and Cord: LP2CC36 Single Cable and 4 Wire Cord: LP2CC36X4
PerfLyte 13" Power Feed End Set Straight Cord: LP1EC36 Emg/2cir/Dim: LP1EC36X4
Application Data
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
3" (76.2 mm)
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
2.5"
PerfLyte 9" Power Feed End Set Straight Cord: LP1EC36 Emg/2cir/Dim: LP1EC36X4
0 75 75 75 1 65 63 60 2 57 53 50 3 51 46 41 4 45 39 35 5 40 34 30 6 36 30 26 7 32 26 22 8 29 23 19 9 26 21 17 10 24 18 15
0 80 80 80 1 70 67 64 2 61 57 53 3 54 49 44 4 48 42 37 5 42 36 32 6 38 32 27 7 34 28 24 8 31 25 21 9 28 22 18 10 25 20 16
50' x 70' Space 10' 9' 18" 113 164 7.9 1.5 12' 10.5' 24" 62 124 7.1 1.2
50' x 70' Space 10' 9' 18" 70 166 9.8 1.5 12' 10.5' 24" 57 125 8.6 1.3
Perf 13" (330 mm)
LPL2C2T8: 2 lamp T8 80.7% efficiency, 81.7% ∧18.3% ∨ LPL2C2BX: 2 lamp Biax 71.4% efficiency, 77.9% ∧22.1% ∨
13" Perforated with Louver
Style Series Type Lamps Length Ballast Options
12' x 16' Space 8' 9' 18" 73 161 6.5 1.8
12' x 16' Space 8' 9' 18" 68 163 7.8 1.9
For complete performance data please refer to specification sheets.
All performance data shown are for 2 lamp T8. For other lamping options and complete performance data please refer to specifica- tion sheets.
LP 2 C 3T8
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 48 125 2.8 1.2
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 46 123 9.7 1.3
4 = 4 foot U = Uni-Voltage Blank = no options 8 = 8 foot E = Emergency DS = Dual Switch
4 = 4 foot U = Uni-Voltage Blank = no options 8 = 8 foot E = Emergency DS = Dual Switch 12=12foot Pack X4 = 4 wire forDim D1 = Dim 120v & Switched D2 = Dim 277v Emg
Report No. LRL 200-10F
Report No. LRL 1199-5A
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
Pack X4 = 4 wire forDim D1 = Dim 120v & Switched D2 = Dim 277v Emg
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
Housing: 9" luminaire: 18 gauge perforated steel with 41% open hole pattern. Holes are 1/16" diameter on 3/32" centers. 13" luminaire: 18 gauge perforated steel with 51% open hole pattern. Holes are 1/8" diameter on 5/32" staggered centers. Lamping: Two, three or four T8 fluorescent lamps; or two or three T5 fluorescent lamps, as specified. Reflectors: Semi-Perforated. Die-formed specular aluminum. All others die-formed CRS painted high reflectance white Diffuser: Opal acrylic. Louver: Straight blade louver finished to match housing. Electrical: Ballast is universal voltage,
Finish: Powder coated baked white enamel. Custom colors avail- able, consult factory. Options and Accessories: Dual Switching: Order the DS option for separate row switching. 4 Wire: Order X4 modules for entire run when using dimming and/or switched emergency battery packs. Emergency circuiting; special circuiting – consult factory. Labels: UL, cUL and IBEW.
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
LP1D: 9”Perforated with Louver Indirect/Direct
Application Data
Coefficients of Utilization
Application Data
3" 4.2" Perf
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
Ceiling Susp. Illum. Max. Lum. W/ Height Dist. (FC) Lum. Ratio Sq Ft
2.5"
13" 3.2"
0 72 72 72 1 63 60 58 2 56 52 48 3 49 45 41 4 44 39 35 5 39 34 30 6 35 30 26 7 32 27 23 8 29 24 20 9 26 21 18 10 24 19 16
50' x 70' Space 10' 9' 18" 102 175 8.3 2.4 12' 10.5' 24" 83 132 7.4 2.0
0 80 80 80 1 70 67 65 2 62 57 53 3 55 49 45 4 48 42 38 5 43 37 32 6 38 32 28 7 35 29 24 8 31 25 21 9 28 23 19 10 25 20 16
50' x 70' Space 10' 9' 18" 113 155 8.4 1.7 12' 10.5' 24" 62 116 7.4 1.4
For complete performance data please refer to specification sheets.
12' x 16' Space 8' 9' 18" 99 171 6.9 3.0
12' x 16' Space 8' 9' 18" 111 152 6.9 2.1
For complete performance data please refer to specification sheets.
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 66 129 8.5 2.0
8' x 8' x 5' Cubicle R = 50% 12' 10.5' 24" 74 114 8.2 1.4
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
Reflectances: 80% Ceiling, 50% Wall, 20% Floor Light Loss Factor = .75 (.88 BF x .85)
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
80% Ceiling Cavity Reflectance 20% Floor Cavity Reflectance
Lightolier Lighting Systems are modular lighting systems that offer a wide selection of geometric shapes, architectural profiles, scales and finishes.
Report No. LRL 300-1D
Report No. LRL 200-10K
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。