JA
Lightolier logo
公式取扱説明書

Lightolier PLA2G9LP32U

2 ページ·374 KB·インテリア家具・調度品·PDF·EN
Lightolier PLA2G9LP32U
目次 15セクション Paralyte 2424 PLA2G9LP32U · Mounting Methods · Dimensions · 5-1/2" (140mm) · … 表示非表示
Page 1 of the Lightolier PLA2G9LP32U user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Paralyte 2424 PLA2G9LP32U

Page 1 of 2 2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver Static and Air Return 3 Lamp, T8, 1-5/8" U Lamp

  • Features
  • 23” x 23” louver
  • Efficiency 72.6%.
  • One fixture fits 50 different G type and T type ceiling systems.
  • Only 5 1/2” deep housing.
  • Automatic engaging adjustable seismic clips.
  • Pre-anodized aluminum vertical grain parabolic louver.
  • 3 1/8” deep louver.
  • Low iridescence semi-specular aluminum, standard.
  • Spring-loaded latches.
  • Protective film dust guard.
  • UL-Listed twin knockout access plate.
  • Not for continuous row mounting.
Lightolier PLA2G9LP32U — Paralyte 2424 PLA2G9LP32U diagram (page 1)
図 1 · Paralyte 2424 PLA2G9LP32U

Mounting Methods

*If less than 1 1/2”, STC spacer is required, 2 each end.

Dimensions

Lightolier PLA2G9LP32U — Dimensions diagram (page 1)
図 2 · Dimensions
Lightolier PLA2G9LP32U — Dimensions diagram (page 1)
図 3 · Dimensions
Lightolier PLA2G9LP32U — Dimensions diagram (page 1)
図 4 · Dimensions

5-1/2" (140mm)

Adjustable seismic clip (patented)

Adjustable seismic clip (patented)

24" (610mm)

3-3/4" (95mm)

Lightolier PLA2G9LP32U — 24" (610mm) diagram (page 1)
図 5 · 24" (610mm)

3-7/8" (98mm)

Lightolier PLA2G9LP32U — 3-7/8" (98mm) diagram (page 1)
図 6 · 3-7/8" (98mm)
Lightolier PLA2G9LP32U — 3-7/8" (98mm) diagram (page 1)
図 7 · 3-7/8" (98mm)

24" (610mm)

Adjustable seismic clip (patented)

Adjustable seismic clip (patented)

3" x 3" access plate with two K.O.’s (7/8" dia.)

24" (610mm)

two-directional concealed grid narrow grid system

Job Information Type:

Lightolier PLA2G9LP32U — Job Information Type: diagram (page 1)
図 8 · Job Information Type:

air return capabilities exceed standard requirements (see Folio G50-50)

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2/Folio G50-55 Rev. A
Show 6 more labels / short text on this page
*1-1/2" · standard grid · slot grid · *1-1/2" · *1-1/2" · 4/03
Page 2 of the Lightolier PLA2G9LP32U user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Paralyte 2424 PLA2G9LP32U

Page 2 of 2 2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver Static and Air Return 3 Lamp, T8, 1-5/8" U Lamp

LER = FP - 64.6 IW - 85.0 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $3.79

Photometry Model No. PLA2G9LP32U120O3

Lightolier PLA2G9LP32U — Photometry Model No. PLA2G9LP32U120O3 diagram (page 2)
図 9 · Photometry Model No. PLA2G9LP32U120O3

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 81 78 76 74 72 70 71 70 68 2 76 71 67 67 64 62 65 62 60 3 70 64 69 61 67 54 69 56 53 4 65 57 52 55 61 47 53 50 47 5 60 51 46 49 45 41 48 44 41 6 55 46 41 44 40 36 43 39 36 7 51 42 36 40 35 31 39 34 31 8 47 37 31 36 31 27 36 30 27 9 43 33 28 32 27 23 31 27 23 10 40 30 25 29 24 21 28 24 21 visual comfort probability (rated lumens per lamp 3150.)

ITL33754 LIGHTOLIER PLA2G9LP32U120O3

20 20 20 30 20 40 20 6065 59 56 68 68 62 55 54 71 65 60 56 72 68 63 59 30 20 30 30 30 40 30 60 30 8071 64 59 65 73 67 58 53 75 69 62 55 76 71 64 58 77 73 67 61 ise isese 40 20 40 30 40 40 40 60 40 80 40 100uminaries lengthw74 67 63 66 75 70 62 55 77 72 65 57 78 73 67 60 79 75 69 62 80 76 71 65luminaries crosswi 60 30 60 40 60 60 60 80 60 10077 72 66 59 l 79 74 68 60 79 75 70 62 80 76 71 65 80 77 73 66l 100 40 100 60 100 80 100 10080 76 71 64 81 77 73 66 81 78 74 68 82 78 75 69

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

Ordering Information Explanation of Catalog Number. Example: PLA2G9LP32U120O3GLR

PL

A 2

G

P

2U

Voltage120 or 277 Options: Add appropriate suffix to catalog
Body StyleA = Air Handling
Ceiling TypeG =Grid (lay-in T-bar)
Ballast CoverP =Dual V Reflector

Lamp/ Fixture Length:

24243-1/8" Deep Parabolic Precision Contoured Pre-

2U= T8, 1-5/8" U Lamp (Nominal 24")

Louver FinishL = Low

Ballast Type:

Semi-specular (standard) W= White Paint

Other dimming options. Consult factory.

Options & Accessories Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long), Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14. Fusing: Internal fast-blow fusing. Suffix: GLR.

Specifications (continued) lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak or equal). rails hemmed over and housing ends turned-in for safe handling. Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.

Internal slow-blow fusing. Suffix: GMF. Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R. One per ballast. Suffix: B. Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory. T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.

Specifications Performance: In an installation of 3 lamp, 31W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than 78. To prevent glare the VCP shall not be less than 79 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1078 footlamberts. To control veiling reflections, luminaire output in the 30° - 90° zone shall not be less than 67.3%. Air Return: Designed to provide optimum air return. Air is returned through the

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2/Folio G50-55 Rev. A
Show 11 more labels / short text on this page
room cavity ratio · Paralyte · Fixture · Number of · Lamp Quantity · Width · Cells · /Static · Iridescence · anodized Aluminum · Louver
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier PLA2G9LP32Uについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier PLA2G9LP32Uに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier PLA2G9LP32U 取扱説明書(PDF)

2 ページ·374 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…