Page 1 of 2 Direct/Indirect 1' x 4' Recessed Fluorescent 6 Cell White Parabolic Louver With Lens Overlay, 1 Lamp or 2 Lamp T5




Exposed T-bar by others
1-1/2" max.
Exposed T-bar by others
Acoustical material by others
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling


louver hinges from either side
hold-down clips (1 at each end)

Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect 1' x 4' Recessed Fluorescent 6 Cell White Parabolic Louver With Lens Overlay, 1 Lamp or 2 Lamp T5
Model No. PPH1G6FW228UNVPG LER = FP - 72.9 IW - 62.6 BF - 1.0 Comparative yearly lighting energy cost per
Model No. PPH1G6FV228UNVPG LER = FP - 66.3 IW - 62.5 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.29
1000 lumens = $3.62


0 1939 1939 1939
0 1832 1832 1832
5 1902 1924 1944 182
5 1797 1819 1834 173
interior, white painted 6 cell parabolic louver with .140 prismatic overlay Ballast: B228PUNV95-D Report is based on 2900 Lumens per lamp. Efficiency: 68.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.0 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.040 11.040
15 1708 1708 1704 481
interior, white painted 6 cell parabolic louver with .095 prismatic overlay. Ballast: B228PUNV95-D Report is based on 2900 Lumens per lamp. Efficiency: 71.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.040 11.040
15 1695 1719 1730 484
25 1462 1443 1422 665
25 1536 1538 1537 708
35 1256 1172 1140 741
35 1330 1284 1216 800
45 1034 890 826 699
45 1090 964 882 752
55 795 599 597 577
55 825 648 629 615
65 534 364 325 388
65 541 385 323 400
75 252 148 130 177
75 251 156 138 182
85 41 34 32 38
85 41 34 33 39
90 3 3 3
90 3 3 3
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
COEFFICIENTS OF UTILIZATION –
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT 00-030 1328 22.9 33.6 00-040 2069 35.7 52.4 00-060 3346 57.7 84.7 00-090 3949 68.1 100.0 90-180 0000 0.0 000.0 00-180 3949 68.1 100.0
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 1365 23.5 32.9 00-040 2164 37.3 52.1 00-060 3532 60.9 85.0 00-090 4154 71.6 100.0 90-180 0000 00.0 000.0 00-180 4154 71.6 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 72 72 69 68 66 64 65 63 62 02 69 64 59 60 57 54 58 55 53 03 63 56 51 53 49 46 52 48 45 04 58 50 45 48 43 40 46 42 39 05 54 45 40 43 39 35 42 38 35 06 50 41 35 39 35 31 38 34 31 07 46 38 32 36 31 28 35 31 27 08 43 35 29 33 28 25 32 28 25 09 41 32 26 31 26 23 30 26 23 10 38 29 24 28 24 21 28 24 21
01 79 76 73 71 69 67 68 67 65 02 72 67 62 63 60 57 61 58 55 03 66 59 54 56 52 48 54 51 47 04 61 53 47 50 46 42 49 45 41 05 56 48 42 45 40 37 44 40 36 06 52 43 37 41 36 32 40 36 32 07 49 39 33 38 33 29 37 32 29 08 45 36 30 35 30 26 34 29 26 09 42 33 28 32 27 24 31 27 23 10 40 31 25 30 25 21 29 25 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4363. 3755. 3485. 55 4135. 3116. 3105. 65 3770. 2570. 2294. 75 02905. 1706. 1499. 85 01404. 1164. 1095.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4599. 4068. 3722. 55 4291. 3371. 3272. 65 3819. 2718. 2280. 75 2893. 1798. 1591. 85 1404. 1164. 1130.
G
F
Lamp Quantity 1=1 Lamp 2=2 Lamp Paraplus
Ceiling Type:
Fits both Standard Grid
Acrylic .040 Thick W = Pattern 20
Ballast Type:
Prismatic .140 Thick O = K20 with
White Overlay V = .095 Pattern
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Overlay: M=Matte white acrylic .040 thick. W=Pattern 20 prismatic .140 thick. O=K20 with white overlay. V=.095 acrylic pattern 12. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK91X4. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C.
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To reduce glare the average brightness at 65° shall not exceed 2280 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.1%. Materials: Chassis parts are die-formed 20 gauge steel. Housing has all edges turned for safe-handling. Finish: Chassis exterior – baked white powder coated polyester enamel. Cavity – baked white powder coated polyester enamel. Louver – baked white powder coated polyester enamel, minimum 86% reflectance. Rust preventative undercoating.