Page 1 of 2 Direct/Indirect 2' x 2' Recessed Fluorescent 8 Cell White Louver With Lens Overlay, 2 or 3 Lamp T8




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

exposed slot t-grid ceiling


2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
louver hinges from either side

Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect 2' x 2' Recessed Fluorescent 8 Cell White Louver With Lens Overlay, 2 or 3 Lamp T8
Model No. PPH2G8FW217120SO LER = FP - 42.7 IW - 37.7 BF - 0.93 Comparative yearly lighting energy cost per
Model No. PPH2G8FW317120O3 LER = FP - 47.4 IW - 47.4 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $5.62
1000 lumens = $5.06


0 777 777 777
0 1107 1107 1107
5 769 773 777 74
5 1094 1102 1109 105
interior, white painted 8 cell parabolic louver with prismatic overlay. Ballast: Triad B332I120ORH-A Report is based on 1375 Lumens per lamp. Efficiency: 62.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
15 723 738 754 209
interior, white painted 8 cell parabolic louver with prismatic overlay. Ballast: B332I120RH-A Report is based on 1375 Lumens per lamp. Efficiency: 61.7% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
15 1024 1054 1090 299
25 652 675 709 312
25 925 986 1075 458
35 546 568 547 349
35 783 871 924 539
45 393 422 445 314
45 560 650 681 481
55 238 236 260 225
55 326 352 377 326
65 147 157 163 155
65 203 223 225 218
75 73 67 56 72
75 96 91 76 97
85 21 20 16 22
85 24 21 20 24
90
90 2 2 2
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 594 21.6 34.3 00-040 943 34.3 54.5 00-060 1481 53.8 85.6 00-090 1730 62.9 100.0 90-180 0000 0.0 000.0 00-180 1730 62.9 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2361. 2740. 2871. 55 1694. 1829. 1959. 65 1432. 1573. 1587. 75 1106. 1048. 875. 85 821. 718. 684.
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 69 67 64 63 61 59 60 59 57 02 64 59 55 56 53 50 54 51 49 03 59 53 48 50 46 43 48 45 42 04 54 47 42 45 41 37 43 40 37 05 50 42 37 40 36 33 39 35 32 06 46 39 33 37 33 29 36 32 29 07 43 35 30 34 29 26 33 29 26 08 40 32 27 31 27 24 30 26 23 09 38 30 25 29 24 21 28 24 21 10 35 28 23 27 22 20 26 22 19
01 68 65 63 62 60 58 59 58 56 02 63 58 54 55 52 49 53 50 48 03 58 52 47 49 45 42 47 44 42 04 53 46 41 44 40 37 43 39 36 05 49 42 37 40 36 32 39 35 32 06 46 38 33 36 32 29 35 31 28 07 42 35 29 33 29 26 32 28 25 08 40 32 27 30 26 23 30 26 23 09 37 29 24 28 24 21 27 24 21 10 35 27 22 26 22 19 26 22 19
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 861 20.9 33.8 00-040 1400 33.9 55.0 00-060 2207 53.5 86.7 00-090 2546 61.7 100.0 90-180 0000 00.0 000.0 00-180 2546 61.7 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1639. 1760. 1856. 55 1224. 1214. 1337. 65 1026. 1096. 1138. 75 0832. 764. 638. 85 0711. 677. 541.
G
F
Lamp Quantity 2=2 Lamp 3=3 Lamp Paraplus II
Ceiling Type:
Fits both Standard Grid
17=T8 (Nominal 24")
Acrylic .040 Thick W = Pattern 20
Ballast Type:
Prismatic .140 Thick O = K20 with
White Overlay V = .095 Pattern 12
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Overlay: M=Matte white acrylic .040 thick. W=Pattern 20 prismatic .140 thick. O=K20 with white overlay. V=.095 acrylic pattern 12. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2 and CF2FK SPACER. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX C.
Specifications Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67. To reduce glare the average brightness at 65° shall not exceed 1138 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 65.7%. Materials: Chassis parts are die-formed code gauge steel. Housing has all edges turned for safe-handling. Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Louver – baked white post painted acrylic enamel, minimum 86% reflectance. Phosphate undercoating.
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。