90° Outside PTS7C900 Standard PTS7C900A Air
135° Inside PTS7C1351 Standard PTS7C1351A Air
135° Outside PTS7C1350 Standard PTS7C1350A Air
1-1/2” (3.81cm)
Features 1.
Mountings Wall Adjustment Bracket - Allows for inconsistencies in wall straightness. Die-formed steel used to mount system to the wall.
Housing: Die-formed steel, slotted for air return. Integral flanges at each end strengthen the housing and permit housings to be bolted together in continuous runs and facilitate suspension of fixture. Concealed openings for heat extraction and air return.
Finish Ceiling trim painted baked enamel semi-gloss white.
Options and Accessories 90° inside, 90° outside, 135° inside, and 135° outside corerns available.
Labels UL, cUL and I.B.E.W.

Ceiling Trim: Extruded aluminum with integral aligner splines.
Electrical Specify 120 volt or 277 volt. 3 conductor, 18 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off. Dimming: Advance Mark X, use Advance compatible two-wire control (no extra control lead required).
"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

1BHFPG 1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO
Performance & Quick Calculators
CANDLEPOWER SUMMARY ZONE Deg
0 45 90 135 180
180 deg 0 deg
180 175 0 165 0 155 0 145 0 135 0 125 0 115 0 105 0 95 0 90 85 39 15 2 2 2 75 153 90 5 3 3 65 440 120 13 8 9 55 560 338 79 34 14 45 669 532 288 64 32 35 754 705 512 103 55 25 885 833 677 225 104 15 969 949 778 386 285 5 950 920 837 704 620 0 833
0˚ 5˚ 15˚ 25˚ 35˚
REPORT NO: LRL 499-5D LAMPS: 1-FO32T8 EFFICIENCY: 46.7%
ZONE LUMENS % BARELAMP % LUMINAIRE 0-90 1354 46.7 100.0 90-180 0 0.0 0.0 0-180 1354 46.7 100.0
Quick Calculators
ONE SIDE MOUNTING 6 FT BETWEEN WALLS
NO OPPOSITE WALL
DISTANCE FROM CEILING, FT
1.5 63 2.5 33 3.5 22 4.5 18 76 51 33 23 18 15 5.5 16 6.5 15 7.5 14 51 45 35 28 23 19 8.5 12 9.5 12 40 38 33 27 23 20
1.5 72 39 2.5 43 45 3.5 33 45 4.5 28 85 68 43 5.5 26 40 6.5 24 37 7.5 22 60 55 33 8.5 21 30 9.5 19 49 48 28
0 2 4 6 8 10 12 DISTANCE FROM WALL, FEET
TWO SIDE MOUNTING 12 FT BETWEEN WALLS
1.5 76 76 2.5 50 50 3.5 41 41 4.5 38 92 73 65 73 92 38 5.5 37 37 6.5 35 35 7.5 34 72 71 69 71 72 34 8.5 33 33 9.5 32 63 66 65 66 63 32
VERTICAL FC
0 2 4 6 8 10 12 DISTANCE FROM WALL, FEET
Ordering Instructions Individual Fixtures: 1. Order number of FIXTURES. 2. Order one END PLATE SET per fixture. Continuous Rows: 1. Determine run length. 2. Use chart above to find catalog numbers. Each run ends with a telescoping unit. 3. Order END PLATE SET for each open run. Square/Rectangle Patterns: 1. Consult plans and mark locations for corners. 2. Calculate net footage of each run. 3. Deduct corner dimension from each corner. 4. Determine catalog numbers the same way as a straight run.
Blank = T12 Magnetic 120v 2 =T12 Magnetic 277v E1 = T12 Electronic 120v E2 = T12 Electronic 227v E81 = T8 Electronic 120v E82 = T8 Electronic 227v M71 = T8 Electronic Dimming Ballast 120v M72 = T8 Electronic Dimming Ballast 277v