JA
Lightolier logo
公式取扱説明書

Lightolier QHE1GPFOP128

2 ページ·107 KB·インテリア家具・調度品·PDF·EN
Lightolier QHE1GPFOP128
目次 27セクション QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE1GPFOP128 OR 228 · Page 1 of 2 · Mounting Methods / Features · Dimensions · … 表示非表示
Page 1 of the Lightolier QHE1GPFOP128 user manual — ®
1ページ · クリックして拡大
1ページ

QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE1GPFOP128 OR 228

Page 1 of 2

1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 1 OR 2 LAMP, T5 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Lightolier QHE1GPFOP128 — Page 1 of 2 diagram (page 1)
図 1 · Page 1 of 2
  • Efficiency 57.6% (2 lamp T5).
  • Swing down microperforated lamp shield for easy relamping and maintenance.
  • Alter soft white film on inside of mesh conceals lamp image and provide balance between reflected light and direct light.
  • Fully recessed luminaire and lamp compartment.
  • 95% Reflective Alter soft white paint finish.
  • One piece body for easy installation.
  • Easy access to ballast through lamp compartment.
  • Fits standard T-Grid ceilings. (G type)

Mounting Methods / Features

Dimensions

Lightolier QHE1GPFOP128 — Mounting Methods / Features diagram (page 1)
図 2 · Mounting Methods / Features
Lightolier QHE1GPFOP128 — Mounting Methods / Features diagram (page 1)
図 3 · Mounting Methods / Features

Suited to standard exposed T-grid ceilings

Suited to standard exposed Slot T-grid ceilings

Microperforated mesh lamp shield

Lightolier QHE1GPFOP128 — Mounting Methods / Features diagram (page 1)
図 4 · Mounting Methods / Features
Lightolier QHE1GPFOP128 — Mounting Methods / Features diagram (page 1)
図 5 · Mounting Methods / Features

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-38

®

Ceiling compatibility

Page 2 of the Lightolier QHE1GPFOP128 user manual — ®
2ページ · クリックして拡大
2ページ

QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE1GPFOP128 OR 228

QVA2GSDOS2FT

Page 2 of 2

1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 1 OR 2 LAMP, T5 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry Model No. : QHE1GPFOP2 54120PG

CERTIFIED TEST REPORT NO. LSCA264 COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QHE1GPFOP254120PG WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO 54W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 4400 LMS. ONE UNIVERSAL ACCUSTART 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B254PUNV-D

CERTIFIED TEST REPORT NO. LSCA264 COMPUTED BY LSC PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1901 5 1904 1895 1896 1894 1896 183 10 1874 1879 1881 1884 1886 15 1831 1833 1851 1857 1854 520 20 1777 1775 1798 1805 1810 25 1709 1708 1724 1739 1740 793 30 1613 1616 1651 1649 1648 35 1510 1528 1550 1537 1524 955 40 1382 1405 1437 1384 1364 45 1250 1278 1274 1204 1174 954 50 1097 1132 1088 1004 975 55 942 977 894 811 781 791 60 791 798 685 632 633 65 633 607 494 499 504 541 70 484 420 366 386 381 75 332 242 242 257 261 277 80 179 117 133 146 140 85 47 36 42 44 46 58 90

LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QVS1GPFOP254120PG WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO 54W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 4400 LMS. ONE UNIVERSAL ACCUSTART 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B254PUNV-D

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

0 .69 .67 .64 .64 .64 .61 .61 .61 .59 .59 .59 .58

ZONAL LUMENS AND PERCENTAGES

1 .63 .61 .59 .57 .62 .60 .58 .56 .57 .56 .54 .55 .54 .53 .53 .52 .51 .50

ZONE LUMENS % LAMP %LUMINAIRE 0-30 1496 17.00 29.51 0-40 2451 27.85 48.34 0-60 4195 47.68 82.73 0-90 5071 57.63 100.00 40-90 2620 29.77 51.66 60-90 875 9.95 17.27 90-180 0 .00 .00 0-180 5071 57.63 100.00

2 .58 .54 .51 .48 .57 .53 .50 .47 .51 .48 .46 .49 .47 .45 .48 .46 .44 .43

3 .54 .48 .44 .41 .52 .47 .43 .40 .46 .42 .40 .44 .41 .39 .43 .40 .38 .37

4 .49 .43 .38 .35 .48 .42 .38 .35 .41 .37 .34 .40 .36 .34 .38 .36 .33 .32

5 .45 .38 .33 .30 .44 .38 .33 .30 .36 .32 .29 .35 .32 .29 .34 .31 .29 .27

6 .42 .34 .29 .26 .41 .34 .29 .26 .33 .29 .25 .32 .28 .25 .31 .28 .25 .24

** EFFICIENCY = 57.6% **

7 .38 .31 .26 .23 .38 .30 .26 .22 .30 .25 .22 .29 .25 .22 .28 .25 .22 .21

LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .91 S/MH = 1.3 SC = 1.3

8 .35 .28 .23 .20 .35 .27 .23 .19 .27 .22 .19 .26 .22 .19 .25 .22 .19 .18

9 .33 .25 .20 .17 .32 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .17 .16

ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 5593 5721 5274 DATE: 55 5197 4951 4326 APR 26, 2004 65 4740 3712 3784 PREPARED FOR: 75 4062 2967 3201 LIGHTOLIER-CFI 85 1695 1535 1688 CORNWALL, ONTARIO

10 .30 .23 .18 .15 .30 .22 .18 .15 .22 .18 .15 .21 .17 .15 .21 .17 .15 .14

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 104.6 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Ordering Information Explanation of Catalogue Number Example: QHE1GPFOP228120PI

QHE G 1 PF 2 OP 28 120 PI

LAMP QUANTITY

OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)

QUALITY

VOLTAGE CEILING TYPE G=Standard exposed T-grid ceilings T=Slot T-grid ceiling

HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system

120V 277V 347V

LAMP/FIXTURE

FIXTURE

LAMP SHIELD PF = Microperforated

WIDTH

LENGTH (NOMINAL 48'')

BALLAST

28 = 28W T5 54 = 54W T5

PI = Electronic linear T5, IS PG* = Electronic linear T5HO, Pro. S * 54W N/A in PI

LAMP SHIELD

DETAIL

OP = One piece (no center slot)

SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Type: Job Information

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-38

®

1'

Lightolier QHE1GPFOP128について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier QHE1GPFOP128に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier QHE1GPFOP128 取扱説明書(PDF)

2 ページ·107 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…