1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 1 OR 2 LAMP, T5 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Dimensions


Suited to standard exposed T-grid ceilings
Suited to standard exposed Slot T-grid ceilings
Microperforated mesh lamp shield


Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-38
Ceiling compatibility

QVA2GSDOS2FT
1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 1 OR 2 LAMP, T5 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
CERTIFIED TEST REPORT NO. LSCA264 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QHE1GPFOP254120PG WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO 54W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 4400 LMS. ONE UNIVERSAL ACCUSTART 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B254PUNV-D
CERTIFIED TEST REPORT NO. LSCA264 COMPUTED BY LSC PROGRAM **TEST-LITE**
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1901 5 1904 1895 1896 1894 1896 183 10 1874 1879 1881 1884 1886 15 1831 1833 1851 1857 1854 520 20 1777 1775 1798 1805 1810 25 1709 1708 1724 1739 1740 793 30 1613 1616 1651 1649 1648 35 1510 1528 1550 1537 1524 955 40 1382 1405 1437 1384 1364 45 1250 1278 1274 1204 1174 954 50 1097 1132 1088 1004 975 55 942 977 894 811 781 791 60 791 798 685 632 633 65 633 607 494 499 504 541 70 484 420 366 386 381 75 332 242 242 257 261 277 80 179 117 133 146 140 85 47 36 42 44 46 58 90
LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QVS1GPFOP254120PG WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO 54W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 4400 LMS. ONE UNIVERSAL ACCUSTART 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B254PUNV-D
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .69 .67 .64 .64 .64 .61 .61 .61 .59 .59 .59 .58
1 .63 .61 .59 .57 .62 .60 .58 .56 .57 .56 .54 .55 .54 .53 .53 .52 .51 .50
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1496 17.00 29.51 0-40 2451 27.85 48.34 0-60 4195 47.68 82.73 0-90 5071 57.63 100.00 40-90 2620 29.77 51.66 60-90 875 9.95 17.27 90-180 0 .00 .00 0-180 5071 57.63 100.00
2 .58 .54 .51 .48 .57 .53 .50 .47 .51 .48 .46 .49 .47 .45 .48 .46 .44 .43
3 .54 .48 .44 .41 .52 .47 .43 .40 .46 .42 .40 .44 .41 .39 .43 .40 .38 .37
4 .49 .43 .38 .35 .48 .42 .38 .35 .41 .37 .34 .40 .36 .34 .38 .36 .33 .32
5 .45 .38 .33 .30 .44 .38 .33 .30 .36 .32 .29 .35 .32 .29 .34 .31 .29 .27
6 .42 .34 .29 .26 .41 .34 .29 .26 .33 .29 .25 .32 .28 .25 .31 .28 .25 .24
7 .38 .31 .26 .23 .38 .30 .26 .22 .30 .25 .22 .29 .25 .22 .28 .25 .22 .21
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .91 S/MH = 1.3 SC = 1.3
8 .35 .28 .23 .20 .35 .27 .23 .19 .27 .22 .19 .26 .22 .19 .25 .22 .19 .18
9 .33 .25 .20 .17 .32 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .17 .16
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 5593 5721 5274 DATE: 55 5197 4951 4326 APR 26, 2004 65 4740 3712 3784 PREPARED FOR: 75 4062 2967 3201 LIGHTOLIER-CFI 85 1695 1535 1688 CORNWALL, ONTARIO
10 .30 .23 .18 .15 .30 .22 .18 .15 .22 .18 .15 .21 .17 .15 .21 .17 .15 .14
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 104.6 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
QHE G 1 PF 2 OP 28 120 PI
OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
VOLTAGE CEILING TYPE G=Standard exposed T-grid ceilings T=Slot T-grid ceiling
HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system
LAMP/FIXTURE
FIXTURE
LAMP SHIELD PF = Microperforated
LENGTH (NOMINAL 48'')
BALLAST
28 = 28W T5 54 = 54W T5
PI = Electronic linear T5, IS PG* = Electronic linear T5HO, Pro. S * 54W N/A in PI
DETAIL
OP = One piece (no center slot)
SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-38