1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 LAMP, T8 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Dimensions


Suited to standard exposed T-grid ceilings
Suited to standard exposed Slot T-grid ceilings
Microperforated mesh lamp shield


Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-37
Ceiling compatibility

QVA2GSDOS2FT
1’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 LAMP, T8 5'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
CERTIFIED TEST REPORT NO. LSCA268 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QHE1GPFOP232120SO WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P32-SC
CERTIFIED TEST REPORT NO. LSCA268 COMPUTED BY LSC PROGRAM **TEST-LITE**
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1372 5 1363 1376 1369 1372 1359 132 10 1362 1357 1350 1357 1362 15 1323 1319 1326 1343 1334 374 20 1280 1283 1287 1303 1300 25 1235 1234 1245 1253 1248 572 30 1161 1172 1195 1191 1193 35 1091 1102 1113 1111 1098 689 40 1007 1021 1023 1006 989 45 920 929 918 886 863 696 50 818 816 787 746 719 55 702 704 658 605 595 582 60 589 581 509 485 475 65 475 447 377 371 373 403 70 376 314 272 279 284 75 263 178 177 184 186 207 80 148 97 93 102 95 85 40 32 39 34 35 45 90
LIGHTOLIER-CFI 1x4 RECESSED LUMINAIRE CAT. NO. QVS1GPFOP232120SO WHITE PAINTED REFLECTOR AND ONE PERFORATED LAMP SHIELD WITH OVERLAY TWO F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P32-SC
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .75 .73 .70 .70 .70 .67 .67 .67 .64 .64 .64 .63
1 .69 .66 .64 .62 .67 .65 .63 .61 .62 .61 .59 .60 .59 .57 .58 .57 .55 .54
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1078 18.28 29.15 0-40 1767 29.96 47.78 0-60 3045 51.61 82.30 0-90 3699 62.71 100.00 40-90 1931 32.75 52.22 60-90 654 11.10 17.70 90-180 0 .00 .00 0-180 3699 62.71 100.00
2 .63 .59 .55 .52 .62 .58 .54 .51 .55 .52 .50 .53 .51 .49 .52 .50 .48 .46
3 .58 .52 .48 .44 .57 .51 .47 .44 .50 .46 .43 .48 .45 .42 .46 .44 .41 .40
4 .54 .47 .42 .38 .52 .46 .41 .37 .44 .40 .37 .43 .39 .36 .42 .39 .36 .35
5 .49 .41 .36 .32 .48 .41 .36 .32 .39 .35 .32 .38 .34 .31 .37 .34 .31 .30
6 .45 .37 .32 .28 .44 .37 .31 .28 .35 .31 .28 .34 .30 .27 .33 .30 .27 .26
7 .42 .33 .28 .25 .41 .33 .28 .24 .32 .27 .24 .31 .27 .24 .30 .27 .24 .22
8 .38 .30 .25 .21 .37 .29 .25 .21 .29 .24 .21 .28 .24 .21 .27 .23 .21 .19
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .91 S/MH = 1.3 SC = 1.3
9 .35 .27 .22 .18 .34 .27 .22 .18 .26 .21 .18 .25 .21 .18 .25 .21 .18 .17
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 4119 4124 3876 DATE: 55 3874 3644 3294 APR 27, 2004 65 3555 2833 2804 PREPARED FOR: 75 3218 2167 2288 LIGHTOLIER-CFI 85 1460 1417 1292 CORNWALL, ONTARIO
10 .33 .25 .19 .16 .32 .24 .19 .16 .24 .19 .16 .23 .19 .16 .22 .19 .16 .15
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 56.5 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
QHE G 1 PF 2 OP 32 120 SO
OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
VOLTAGE CEILING TYPE Standard exposed T-grid ceilings
HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system
LAMP/FIXTURE
FIXTURE
LAMP SHIELD PF = Microperforated
LENGTH (NOMINAL 48'')
BALLAST
32 = 32W T8
OC = Magnetic T8 SO = Electronic linear T8 instant start SR = Electronic linear T8 rapid start PS = PowerSpec
DETAIL
OP = One piece (no center slot)
SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L20-37