2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T8 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Dimensions


Suited to standard exposed T-grid ceilings
Suited to standard exposed Slot T-grid ceilings
Microperforated mesh lamp shield


Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-26
Ceiling compatibility

QVA2GSDOS2FT
2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T8 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
CERTIFIED TEST REPORT NO. LSCA260 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP217120SO WHITE REFLECTOR, SILVER BALLAST COVER, ONE PERF. LAMP SHIELD WITH OVERLAY TWO 17W T8 FLUORESCENT LAMPS. LUMEN RATING = 1400 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P17-RH-TP
CERTIFIED TEST REPORT NO. LSCA260 COMPUTED BY LSC PROGRAM **TEST-LITE**
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 606 5 603 604 606 604 604 58 10 594 599 600 600 602 15 582 585 587 593 593 166 20 563 563 573 579 583 25 535 539 547 559 565 253 30 501 506 523 539 547 35 465 472 493 516 525 309 40 422 436 463 490 501 45 377 394 428 460 473 329 50 327 350 389 426 440 55 278 304 347 384 401 307 60 225 259 302 338 349 65 176 210 252 277 285 239 70 134 161 195 205 202 75 92 113 125 128 134 127 80 54 61 66 73 76 85 22 27 24 23 26 30 90
LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP217120SO WHITE REFLECTOR, SILVER BALLAST COVER, ONE PERF. LAMP SHIELD WITH OVERLAY TWO 17W T8 FLUORESCENT LAMPS. LUMEN RATING = 1400 LMS. ONE ADVANCE 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. REL-2P17-RH-TP
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .77 .75 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65
1 .71 .68 .66 .63 .69 .67 .64 .62 .64 .62 .60 .61 .60 .58 .59 .58 .57 .55
ZONE LUMENS % LAMP %LUMINAIRE 0-30 476 17.04 26.25 0-40 785 28.06 43.24 0-60 1421 50.75 78.20 0-90 1817 64.91 100.00 40-90 1031 36.84 56.76 60-90 396 14.15 21.80 90-180 0 .00 .00 0-180 1817 64.91 100.00
2 .65 .60 .56 .52 .63 .59 .55 .51 .56 .53 .50 .54 .52 .49 .52 .50 .48 .47
3 .59 .53 .48 .44 .58 .52 .47 .43 .50 .46 .43 .48 .45 .42 .47 .44 .41 .40
4 .54 .47 .41 .37 .53 .46 .41 .37 .44 .40 .36 .43 .39 .36 .41 .38 .35 .34
5 .50 .41 .36 .31 .48 .41 .35 .31 .39 .34 .31 .38 .34 .30 .37 .33 .30 .29
6 .46 .37 .31 .27 .44 .36 .31 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25
7 .42 .33 .27 .24 .41 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .93 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3
8 .39 .30 .24 .20 .38 .29 .24 .20 .28 .23 .20 .27 .23 .20 .27 .23 .20 .18
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 1562 1778 1968 DATE: 55 1418 1781 2053 APR 21, 2004 65 1217 1753 1981 PREPARED FOR: 75 1046 1415 1519 LIGHTOLIER-CFI 85 730 820 883 CORNWALL, ONTARIO
9 .35 .27 .21 .17 .35 .26 .21 .17 .25 .21 .17 .25 .20 .17 .24 .20 .17 .16
10 .33 .24 .19 .15 .32 .24 .19 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .14
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 33.2 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
QHE G 2 2 OP 17
OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
VOLTAGE CEILING TYPE Standard exposed T-grid ceilings
HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system
LAMP/FIXTURE
FIXTURE
LAMP SHIELD PF = Microperforated
LENGTH
17 = 17W T8
BALLAST
OC = Magnetic T8 SC = 1 or 2 LPB electronic T8 1S SR = 1 or 2 LPB electronic T8 RS O3 = 3 LPB electronic T8 1S R3 = 3 LPB electronic T8 RS PS = PowerSpec HDF dimming elect. T8
DETAIL
OP = One piece (no center slot)
SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-26