QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP224 OR 334

Page 1 of 2

2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Lightolier QHE2GPFOP324 — Page 1 of 2 diagram (page 1)
図 1 · Page 1 of 2
  • Efficiency 68.6% (2 lamp T5HO).
  • Swing down microperforated lamp shield for easy relamping and maintenance.
  • Alter soft white film on inside of mesh conceals lamp image and provide balance between reflected light and direct light.
  • Fully recessed luminaire and lamp compartment.
  • 95% Reflective Alter soft white paint finish.
  • Specular interior reflector.
  • One piece body for easy installation.
  • Exclusive socket locks lamp into place.
  • Easy access to ballast through lamp compartment.
  • Fits standard T-Grid ceilings.

Mounting Methods / Features

Dimensions

Lightolier QHE2GPFOP324 — Mounting Methods / Features diagram (page 1)
図 2 · Mounting Methods / Features
Lightolier QHE2GPFOP324 — Mounting Methods / Features diagram (page 1)
図 3 · Mounting Methods / Features

Suited to standard exposed T-grid ceilings

Suited to standard exposed Slot T-grid ceilings

Microperforated mesh lamp shield

Lightolier QHE2GPFOP324 — Mounting Methods / Features diagram (page 1)
図 4 · Mounting Methods / Features
Lightolier QHE2GPFOP324 — Mounting Methods / Features diagram (page 1)
図 5 · Mounting Methods / Features

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-27

®

Ceiling compatibility

Page 2 of the Lightolier QHE2GPFOP324 user manual — ®
2ページ · クリックして拡大
2ページ

QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP224 OR 334

QVA2GSDOS2FT

Page 2 of 2

2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry Model No. : QHE2GPFOP224120PG

CERTIFIED TEST REPORT NO. LSCA267 COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP224120PG WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 24W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 1760 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. B224PUNV-C

CERTIFIED TEST REPORT NO. LSCA267 COMPUTED BY LSC PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 817 5 803 814 805 806 814 78 10 796 795 798 801 809 15 782 778 788 789 795 222 20 747 756 761 775 777 25 712 723 739 751 754 338 30 676 684 704 722 731 35 626 634 666 683 693 414 40 574 593 619 649 670 45 511 530 569 606 620 438 50 440 466 518 556 579 55 377 402 464 504 526 406 60 308 339 405 444 455 65 242 273 338 361 369 314 70 175 212 253 269 267 75 124 141 161 166 168 166 80 65 76 92 103 97 85 21 32 32 35 35 39 90

LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP224120PG WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 24W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 1760 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. B224PUNV-C

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

0 .82 .80 .76 .76 .76 .73 .73 .73 .70 .70 .70 .69

ZONAL LUMENS AND PERCENTAGES

1 .75 .72 .69 .67 .73 .71 .68 .66 .68 .66 .64 .65 .63 .62 .63 .61 .60 .59

ZONE LUMENS % LAMP %LUMINAIRE 0-30 637 18.12 26.42 0-40 1051 29.87 43.55 0-60 1895 53.86 78.52 0-90 2414 68.59 100.00 40-90 1362 38.72 56.45 60-90 518 14.74 21.48 90-180 0 .00 .00 0-180 2414 68.59 100.00

2 .69 .63 .59 .55 .67 .62 .58 .54 .59 .56 .53 .57 .55 .52 .55 .53 .51 .49

3 .63 .56 .51 .46 .61 .55 .50 .46 .53 .49 .45 .51 .47 .44 .49 .46 .44 .42

4 .58 .50 .44 .39 .56 .49 .43 .39 .47 .42 .39 .45 .41 .38 .44 .40 .38 .36

5 .53 .44 .38 .33 .51 .43 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .30

6 .48 .39 .33 .29 .47 .38 .33 .28 .37 .32 .28 .36 .31 .28 .35 .31 .28 .26

** EFFICIENCY = 68.6% **

7 .44 .35 .29 .25 .43 .35 .29 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .23

LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .93 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3

8 .41 .31 .26 .21 .40 .31 .25 .21 .30 .25 .21 .29 .24 .21 .28 .24 .21 .20

9 .38 .28 .22 .18 .37 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17

ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 2118 2367 2578 DATE: 55 1923 2377 2695 APR 27, 2004 65 1674 2353 2566 PREPARED FOR: 75 1405 1826 1907 LIGHTOLIER-CFI 85 722 1066 1189 CORNWALL, ONTARIO

10 .35 .26 .20 .16 .34 .25 .20 .16 .25 .20 .16 .24 .19 .16 .23 .19 .16 .15

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 50.7 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP224120PG

QHE G 2 2 OP 24

LAMP QUANTITY

OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)

QUALITY

VOLTAGE CEILING TYPE Standard exposed T-grid ceilings

HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system

120V 277V 347V

LAMP/FIXTURE

FIXTURE

LAMP SHIELD PF = Microperforated

WIDTH

LENGTH (NOMINAL 20'')

BALLAST

14 = 14W T5 24 = 24W T5HO

PG = Electronic linear T5, Pro S

LAMP SHIELD

DETAIL

OP = One piece (no center slot)

SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Type: Job Information

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-27

®

2'

Lightolier QHE2GPFOP324について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier QHE2GPFOP324に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier QHE2GPFOP324 取扱説明書(PDF)

2 ページ·120 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…