2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Dimensions


Suited to standard exposed T-grid ceilings
Suited to standard exposed Slot T-grid ceilings
Microperforated mesh lamp shield


Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-27
Ceiling compatibility

QVA2GSDOS2FT
2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
CERTIFIED TEST REPORT NO. LSCA267 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP224120PG WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 24W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 1760 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. B224PUNV-C
CERTIFIED TEST REPORT NO. LSCA267 COMPUTED BY LSC PROGRAM **TEST-LITE**
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 817 5 803 814 805 806 814 78 10 796 795 798 801 809 15 782 778 788 789 795 222 20 747 756 761 775 777 25 712 723 739 751 754 338 30 676 684 704 722 731 35 626 634 666 683 693 414 40 574 593 619 649 670 45 511 530 569 606 620 438 50 440 466 518 556 579 55 377 402 464 504 526 406 60 308 339 405 444 455 65 242 273 338 361 369 314 70 175 212 253 269 267 75 124 141 161 166 168 166 80 65 76 92 103 97 85 21 32 32 35 35 39 90
LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP224120PG WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 24W T5 HO FLUORESCENT LAMPS. LUMEN RATING = 1760 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. B224PUNV-C
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .82 .80 .76 .76 .76 .73 .73 .73 .70 .70 .70 .69
1 .75 .72 .69 .67 .73 .71 .68 .66 .68 .66 .64 .65 .63 .62 .63 .61 .60 .59
ZONE LUMENS % LAMP %LUMINAIRE 0-30 637 18.12 26.42 0-40 1051 29.87 43.55 0-60 1895 53.86 78.52 0-90 2414 68.59 100.00 40-90 1362 38.72 56.45 60-90 518 14.74 21.48 90-180 0 .00 .00 0-180 2414 68.59 100.00
2 .69 .63 .59 .55 .67 .62 .58 .54 .59 .56 .53 .57 .55 .52 .55 .53 .51 .49
3 .63 .56 .51 .46 .61 .55 .50 .46 .53 .49 .45 .51 .47 .44 .49 .46 .44 .42
4 .58 .50 .44 .39 .56 .49 .43 .39 .47 .42 .39 .45 .41 .38 .44 .40 .38 .36
5 .53 .44 .38 .33 .51 .43 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .30
6 .48 .39 .33 .29 .47 .38 .33 .28 .37 .32 .28 .36 .31 .28 .35 .31 .28 .26
7 .44 .35 .29 .25 .43 .35 .29 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .23
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .93 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3
8 .41 .31 .26 .21 .40 .31 .25 .21 .30 .25 .21 .29 .24 .21 .28 .24 .21 .20
9 .38 .28 .22 .18 .37 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .18 .17
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 2118 2367 2578 DATE: 55 1923 2377 2695 APR 27, 2004 65 1674 2353 2566 PREPARED FOR: 75 1405 1826 1907 LIGHTOLIER-CFI 85 722 1066 1189 CORNWALL, ONTARIO
10 .35 .26 .20 .16 .34 .25 .20 .16 .25 .20 .16 .24 .19 .16 .23 .19 .16 .15
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 50.7 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
QHE G 2 2 OP 24
OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
VOLTAGE CEILING TYPE Standard exposed T-grid ceilings
HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system
LAMP/FIXTURE
FIXTURE
LAMP SHIELD PF = Microperforated
LENGTH (NOMINAL 20'')
BALLAST
14 = 14W T5 24 = 24W T5HO
PG = Electronic linear T5, Pro S
DETAIL
OP = One piece (no center slot)
SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-27