QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP1FT, 2FT OR 3FT

Page 1 of 2

2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 1, 2 OR 3 LAMP, TT5 BI-TUBE 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Lightolier QHE2GPFOP3FT — Page 1 of 2 diagram (page 1)
図 1 · Page 1 of 2
  • Efficiency 66.3% (2 lamp TT5 40W).
  • Swing down microperforated lamp shield for easy relamping and maintenance.
  • Alter soft white film on inside of mesh conceals lamp image and provide balance between reflected light and direct light.
  • Fully recessed luminaire and lamp compartment.
  • 95% Reflective Alter soft white paint finish.
  • Specular interior reflector.
  • One piece body for easy installation.
  • Exclusive socket locks lamp into place.
  • Easy access to ballast through lamp compartment.
  • Fits standard T-Grid ceilings.

Mounting Methods / Features

Dimensions

Lightolier QHE2GPFOP3FT — Mounting Methods / Features diagram (page 1)
図 2 · Mounting Methods / Features
Lightolier QHE2GPFOP3FT — Mounting Methods / Features diagram (page 1)
図 3 · Mounting Methods / Features

Suited to standard exposed T-grid ceilings

Suited to standard exposed Slot T-grid ceilings

Microperforated mesh lamp shield

Lightolier QHE2GPFOP3FT — Mounting Methods / Features diagram (page 1)
図 4 · Mounting Methods / Features
Lightolier QHE2GPFOP3FT — Mounting Methods / Features diagram (page 1)
図 5 · Mounting Methods / Features

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-28

®

Ceiling compatibility

Page 2 of the Lightolier QHE2GPFOP3FT user manual — ®
2ページ · クリックして拡大
2ページ

QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP1FT, 2FT OR 3FT

QVA2GSDOS2FT

Page 2 of 2

2’ X 2’ RECESSED DIRECT/INDIRECT FLUORESCENT 1, 2 OR 3 LAMP, TT5 BI-TUBE 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry Model No. : QHE2GPFOP2FT120SB

CERTIFIED TEST REPORT NO. LSCA263 COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP2FT120SB WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 40W BIAXIAL COMPACT FLUORESCENT LAMPS. LUMEN RATING = 3150 LMS. ONE MAGNETEK TRIAD 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. C240I120RH

CERTIFIED TEST REPORT NO. LSCA263 COMPUTED BY LSC PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1444 5 1438 1438 1437 1436 1435 139 10 1424 1425 1422 1426 1433 15 1391 1388 1399 1408 1406 394 20 1345 1343 1351 1370 1367 25 1274 1283 1300 1321 1327 598 30 1205 1217 1235 1256 1271 35 1115 1129 1165 1192 1204 724 40 1030 1033 1079 1119 1132 45 919 928 983 1030 1064 757 50 793 819 877 934 960 55 673 700 777 840 858 687 60 550 587 665 725 741 65 431 469 535 584 607 521 70 325 359 411 443 423 75 217 243 278 276 278 279 80 142 139 149 169 166 85 54 75 69 68 63 78 90

LIGHTOLIER-CFI 2x2 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP2FT120SB WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY TWO 40W BIAXIAL COMPACT FLUORESCENT LAMPS. LUMEN RATING = 3150 LMS. ONE MAGNETEK TRIAD 120V 1 OR 2-LAMP ELECTRONIC BALLAST NO. C240I120RH

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

0 .79 .77 .74 .74 .74 .71 .71 .71 .68 .68 .68 .66

ZONAL LUMENS AND PERCENTAGES

1 .73 .70 .67 .65 .71 .68 .66 .64 .65 .63 .62 .63 .61 .60 .60 .59 .58 .57

ZONE LUMENS % LAMP %LUMINAIRE 0-30 1130 17.95 27.07 0-40 1855 29.45 44.42 0-60 3298 52.35 78.97 0-90 4176 66.30 100.00 40-90 2321 36.85 55.58 60-90 878 13.94 21.03 90-180 0 .00 .00 0-180 4176 66.30 100.00

2 .67 .62 .57 .54 .65 .60 .56 .53 .58 .55 .52 .56 .53 .51 .54 .52 .50 .48

3 .61 .54 .49 .45 .59 .53 .49 .45 .51 .47 .44 .50 .46 .43 .48 .45 .43 .41

4 .56 .49 .43 .39 .55 .48 .43 .39 .46 .42 .38 .45 .41 .38 .43 .40 .37 .36

5 .52 .44 .38 .33 .50 .43 .37 .33 .41 .37 .33 .40 .36 .33 .39 .35 .32 .31

6 .48 .39 .33 .29 .46 .38 .33 .29 .37 .32 .29 .36 .32 .28 .35 .31 .28 .27

** EFFICIENCY = 66.3% **

7 .44 .35 .29 .25 .43 .34 .29 .25 .33 .28 .25 .32 .28 .24 .31 .27 .24 .23

LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .92 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3

8 .40 .32 .26 .22 .39 .31 .26 .22 .30 .25 .22 .29 .25 .22 .29 .25 .22 .20

9 .37 .29 .23 .19 .37 .28 .23 .19 .27 .23 .19 .27 .22 .19 .26 .22 .19 .18

ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 3807 4090 4426 DATE: 55 3435 3983 4401 APR 28, 2004 65 2987 3724 4221 PREPARED FOR: 75 2457 3149 3154 LIGHTOLIER-CFI 85 1810 2309 2110 CORNWALL, ONTARIO

10 .35 .26 .21 .17 .34 .26 .21 .17 .25 .20 .17 .24 .20 .17 .24 .20 .17 .16

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 65.2 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP2FT120SB

QHE G 2 2 OP FT

LAMP QUANTITY

OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)

QUALITY

VOLTAGE CEILING TYPE Standard exposed T-grid ceilings

HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system

120V 277V 347V

LAMP/FIXTURE

FIXTURE

LAMP SHIELD PF = Microperforated

WIDTH

LENGTH (NOMINAL 24'')

BALLAST

FT = TT5 Bi-Tube

BE = 50W Elect., TT5 R5 BR = 40W Elect., TT5 R5 BX = 40W Magn., TT5 R5 PB = 40W TT5 Power Spec Dimming* PC = 50/55W TT5 Power Spec Dimming* SB = 40W Generic Elect. TT5 * Not available in 347V

LAMP SHIELD

DETAIL

OP = One piece (no center slot)

SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Type: Job Information

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L10-28

®

2'

Lightolier QHE2GPFOP3FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier QHE2GPFOP3FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier QHE2GPFOP3FT 取扱説明書(PDF)

2 ページ·119 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…