QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP4FT

Page 1 of 2

2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 4 LAMP, TT5 BI-TUBE 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Features

Lightolier QHE2GPFOP4FT — Features diagram (page 1)
図 1 · Features
  • Efficiency 66.8%.
  • Swing down microperforated lamp shield for easy relamping and maintenance.
  • Alter soft white film on inside of mesh conceals lamp image and provide balance between reflected light and direct light.
  • Fully recessed luminaire and lamp compartment.
  • 95% Reflective Alter soft white paint finish.
  • Specular interior reflector.
  • One piece body for easy installation.
  • Easy access to ballast through lamp compartment.
  • Fits standard T-Grid ceilings.
  • Exclusive socket locks lamp into place.

Mounting Methods / Features

Dimensions

Suited to standard exposed T-grid ceilings

Suited to standard exposed Slot T-grid ceilings

Microperforated mesh lamp shield

Lightolier QHE2GPFOP4FT — Mounting Methods / Features diagram (page 1)
図 2 · Mounting Methods / Features

Job Information

Type:

Job Name: Cat. No.:

Lamp(s): Volts/Ballast:

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-34

®

Ceiling compatibility

Page 2 of the Lightolier QHE2GPFOP4FT user manual — ®
2ページ · クリックして拡大
2ページ

QVA2GSDOS2FT ALTER HIGH EFFICIENCY QHE2GPFOP4FT

QVA2GSDOS2FT

Page 2 of 2

2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 4 LAMP, TT5 BI-TUBE 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Photometry Model No. : QHE2GPFOP4FT120SB

CERTIFIED TEST REPORT NO. LSCA266 COMPUTED BY LSC PROGRAM **TEST-LITE**

LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QHE2GPFOP4FT120SB WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY FOUR 40W BIAXIAL COMPACT FLUORESCENT LAMPS. LUMEN RATING = 3150 LMS. TWO UNIVERSAL TRIAD 120V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. C240SI120RH

LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO

CERTIFIED TEST REPORT NO. LSCA266 COMPUTED BY LSC PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 2829 5 2823 2832 2824 2816 2807 273 10 2784 2798 2809 2784 2784 15 2723 2727 2741 2747 2750 771 20 2631 2639 2660 2671 2679 25 2519 2528 2550 2577 2591 1174 30 2379 2391 2443 2465 2487 35 2200 2240 2301 2361 2372 1434 40 2017 2069 2143 2215 2240 45 1806 1866 1966 2065 2108 1512 50 1586 1652 1782 1891 1935 55 1338 1435 1587 1714 1752 1401 60 1107 1204 1386 1500 1526 65 862 993 1164 1243 1251 1097 70 658 766 915 937 926 75 452 551 605 609 624 611 80 262 316 329 365 370 85 89 111 122 132 131 148 90

LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP4FT120SB WHITE REFLECTOR, SILVER BALLAST COVER, PERF. LAMP SHIELD WITH OVERLAY FOUR 40W BIAXIAL COMPACT FLUORESCENT LAMPS. LUMEN RATING = 3150 LMS. TWO UNIVERSAL TRIAD 120V 1 OR 2-LAMP ELECTRONIC BALLASTS NO. C240SI120RH

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

RCR

ZONAL LUMENS AND PERCENTAGES

0 .80 .78 .74 .74 .74 .71 .71 .71 .68 .68 .68 .67

1 .73 .70 .67 .65 .71 .69 .66 .64 .66 .64 .62 .63 .62 .60 .61 .59 .58 .57

ZONE LUMENS % LAMP %LUMINAIRE 0-30 2218 17.61 26.35 0-40 3652 28.99 43.38 0-60 6564 52.10 77.97 0-90 8419 66.82 100.00 40-90 4767 37.84 56.62 60-90 1855 14.72 22.03 90-180 0 .00 .00 0-180 8419 66.82 100.00

2 .67 .62 .58 .54 .65 .60 .57 .53 .58 .55 .52 .56 .53 .51 .54 .52 .50 .48

3 .61 .54 .49 .45 .60 .53 .49 .45 .51 .47 .44 .50 .46 .43 .48 .45 .42 .41

4 .56 .49 .43 .39 .55 .48 .43 .38 .46 .42 .38 .45 .41 .37 .43 .40 .37 .36

5 .52 .43 .38 .33 .50 .43 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .31

6 .48 .39 .33 .29 .46 .38 .33 .29 .37 .32 .28 .36 .31 .28 .35 .31 .28 .26

** EFFICIENCY = 66.8% **

LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .93 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3

7 .44 .35 .29 .25 .43 .34 .29 .25 .33 .28 .25 .32 .28 .24 .31 .27 .24 .23

8 .40 .31 .26 .22 .39 .31 .26 .22 .30 .25 .22 .29 .25 .21 .28 .24 .21 .20

ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 3653 3994 4280 DATE: 55 3337 3973 4387 APR 28, 2004 65 2918 3956 4251 PREPARED FOR: 75 2496 3347 3462 LIGHTOLIER-CFI 85 1461 2009 2167 CORNWALL, ONTARIO

9 .37 .29 .23 .19 .37 .28 .23 .19 .27 .22 .19 .27 .22 .19 .26 .22 .19 .18

10 .35 .26 .21 .17 .34 .26 .21 .17 .25 .20 .17 .24 .20 .17 .24 .20 .17 .15

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 126.3 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP4FT120SB

QHE G 2 OP

LAMP QUANTITY

OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)

QUALITY

VOLTAGE CEILING TYPE Standard exposed T-grid ceilings

HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system

120V 277V 347V

LAMP/FIXTURE

FIXTURE

LAMP SHIELD PF = Microperforated

WIDTH

LENGTH (NOMINAL 24'')

BALLAST

FT = TT5 Bi-Tube FL = Two TT5 Bi-Tube in a 4FT body

BE = 50W Elect., TT5 R5 BR = 40W Elect., TT5 R5 BX = 40W Magn., TT5 R5 PB = 40W TT5 Power Spec Dimming* PC = 50/55W TT5 Power Spec Dimming* SB = 40W Generic Elect. TT5 * Not available in 347V

LAMP SHIELD

DETAIL

OP = One piece (no center slot)

SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL

Type: Job Information

Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-34

®

2'

Lightolier QHE2GPFOP4FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier QHE2GPFOP4FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier QHE2GPFOP4FT 取扱説明書(PDF)

2 ページ·113 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…