Page 1 of 2 Direct/Indirect 2' x 4' with Perforated Baskets
Static, 2 Lamp T5

G exposed T-grid ceiling


1/4" max.
1-1/2" max.

2"x2-1/2" access plate with two K.O.s (7/8" dia.)

drywall kit (see options)
Drywall Kit (see options)
Dry Wall (by others)
Order Catalog Number FK92X4.
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/indirect 2' x 4' with Perforated Baskets
Static, 2 Lamp T5
Model No. SIS2GPF228120PI LER = FP - 55.0 IW - 55.7 BF - 0.93 Comparative yearly lighting energy cost per
Model No. SIS2GPF254120PG LER = FP - 44.5 IW - 122.62 BF - 1.0 Comparative yearly lighting energy cost per
CANDELA DISTRIBUTION
1000 lumens = $4.36
1000 lumens = $5.39


Report Number: G2005287 Catalog Number: SIS2GPF228120PI Lamps: FP28/835 Luminaire: SIS 2'x4' with 2 perforated side baskets. Ballast: Ultrasave Report is based on 2750 Lumens per lamp. Efficiency: 59.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
Report Number: G2005288 Catalog Number: SIS2GPF254120PG Lamps: T5 HO 54W Luminaire: SIS 2'x4' with 2 perforated side baskets. Ballast: QT 2X54/120PHO Report is based on 4400 Lumens per lamp. Efficiency: 61.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
0 1060 1060 1060
0 1757 1757 1757
5 1056 1052 1054
5 1749 1745 1745 166
15 1002 1008 1019 285
15 1658 1670 1687 472
25 906 928 953 428
25 1500 1536 1578 709
35 779 822 869 515
35 1287 1360 1438 852
45 622 702 779 541
45 1027 1160 1288 895
55 446 583 698 517
55 735 964 1155 856
65 268 484 634 465
65 441 802 1054 771
75 141 379 488 358
75 230 631 811 594
85 34 44 49 69
85 52 70 78 109
90
90 5 7 9
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 64 61 58 57 55 53 55 53 51 02 58 53 48 49 46 43 47 44 42 03 52 46 41 43 39 35 41 38 35 04 48 40 35 38 33 30 37 33 29 05 44 36 30 34 29 26 33 29 25 06 40 32 27 31 26 22 29 25 22 07 38 29 24 28 23 20 27 23 20 08 35 27 21 25 21 18 25 20 17 09 33 24 19 23 19 16 23 19 16 10 31 22 18 22 17 14 21 17 14
01 66 63 60 59 57 55 57 55 53 02 60 54 50 51 47 44 49 46 43 03 54 47 42 44 40 37 43 39 36 04 50 42 36 39 35 31 38 34 30 05 45 37 31 35 30 27 34 30 26 06 42 33 28 32 27 23 31 26 23 07 39 30 25 29 24 20 28 23 20 08 36 27 22 26 22 18 25 21 18 09 34 25 20 24 20 16 23 19 16 10 32 23 18 22 18 15 22 18 15
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 0813 14.8 24.8 00-040 1328 24.1 40.5 00-060 2387 43.4 72.8 00-090 3279 59.6 100.0 90-180 0000 0.0 000.0 00-180 3279 59.6 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1347 15.3 24.86798 00-040 2198 25.0 40.5 00-060 3949 44.9 72.8 00-090 5422 61.6 100.0 90-180 0000 0.0 000.0 00-180 5422 61.6 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1267. 1430. 1587. 55 1120. 1464. 1753. 65 914. 1650. 2161. 75 785. 2110. 2717. 85 562. 727. 810.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2109. 2382. 2645. 55 1861. 2441. 2924. 65 1515. 2756. 3621. 75 1290. 3540. 4550. 85 0866. 1166. 1300.
SI
S
G
P
F
Body Style:
Lamp (By Others) 28=28W T5 54=54W T5
Ballast Type:
Options/Accessories Fusing: Internal fast-blow fusing. SUFFIX GLR.
Specifications (continued) Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed.
Internal slow-blow fusing. SUFFIX GMF. Drywall Kit: Order Catalog Number: FK92X4.
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .61. To reduce glare the average brightness at 65° shall not exceed 2161 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.2%. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends are turned-in for safe handling. Lamp Shields: 22 gauge steel perforated mesh lamp shield with white acrylic overlay. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Lamp Shield: Baked flat white acrylic enamel.