Skyway SKS2GPK214 or 224

Page 1 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp T 5 or T5HO

  • Features
  • Aesthetically pleasing triple lens design.
  • Curved high light transmission frost white acrylic side lenses.
  • Clear acrylic conical prismatic center lens.
  • Internal reflector coated with 95% reflective white paint.
  • 72.8% efficient 2 Lamp 14 watt T5.
  • 74.6% efficient 2 Lamp 24 watt T5HO.
  • 5" deep body.
  • Black housing exterior for cooler ballast operating temperature.
  • Eyeleted heat removal vents in fixture ends.
  • Hemmed over side rails for maximum safety.
  • Fixture ends turned-in for safe handling.
  • Built-in earthquake clips (patent no. 5,072,344).
  • Door jamb finished black on four sides for positive light stop.
  • True mitered corner aluminum lens frame.
  • Spring loaded rooster head latches.
  • 18 gauge steel hinges.
  • Construction to meet NYC Code Requirements or Chicago Plenum is available.
Lightolier SKS2GPK214 — Skyway SKS2GPK214 or 224 diagram (page 1)
図 1 · Skyway SKS2GPK214 or 224

Mounting Methods Dimensions

Lightolier SKS2GPK214 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier SKS2GPK214 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier SKS2GPK214 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

24" (610mm)

5" (127mm)

2" max.

2" max.

Air supply slots

(SKA Only)

G T

Exposed T-grid ceiling.

Exposed Slot T-grid ceiling

Lightolier SKS2GPK214 — Air supply slots diagram (page 1)
図 5 · Air supply slots
Lightolier SKS2GPK214 — Air supply slots diagram (page 1)
図 6 · Air supply slots

23-7/8" (606mm)

Drywall Kit (See Options)

15-11/16" (398mm)

2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s

Drywall Kit, Catalog Number: FK92X2.

earthquake clip installed (lay-in grid)

5" (127mm)

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2009 a Philips Group Section 5/Folio MA12-12

Lightolier is a Philips group brand

Show 8 more labels / short text on this page
15/16" or 9/16" · 15/16" or 9/16" · 24" · 24" · Skyway Fixture · Support (by others) · Drywall (by others) · 01/09
Page 2 of the Lightolier SKS2GPK214 user manual — Lightolier is a Philips group brand
2ページ · クリックして拡大
2ページ

Skyway SKS2GPK214 or 224

Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp T 5 or T5HO

Model No. SKS2GPK214UNVPG LER = FP - 56.4 IW - 32.5 BF - 1.05 Comparative yearly lighting energy cost per

Model No. SKS2GPK224UNVPG LER = FP - 52.4 IW - 51.3 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.25

CANDELA DISTRIBUTION

1000 lumens = $4.58

CANDELA DISTRIBUTION

Lightolier SKS2GPK214 — CANDELA DISTRIBUTION diagram (page 2)
図 7

0.0 45.0 90.0 FLUX

Lightolier SKS2GPK214 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Report NumberG2008325 Catalog Number: SKS2GPK214UNVPG Lamps: (2) F14T5/835/ALTO Luminaire: Skyway Recessed 2' x 2' fixture
Report NumberG2008179 Catalog Number: SKS2GPK224UNVPG Lamps: (2) F24T5HO Luminaire: Skyway Recessed 2' x 2' fixture

0 748 748 748

0 1153 1153 1153

5 743 742 742 71

5 1145 1145 1146 109

prismatic acrylic lens assembly. Ballast: ICN-2S28-SC Report is based on 1200 Lumens per lamp. Efficiency: 72.8% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600

15 704 705 705 199

prismatic acrylic lens assembly. Ballast: ICN-2S24 Report is based on 1800 Lumens per lamp. Efficiency: 74.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600

15 1087 1094 1101 309

25 633 643 669 299

25 977 1007 1055 467

35 533 578 612 358

35 822 901 954 557

45 405 420 414 323

45 625 648 639 497

55 263 269 251 237

55 399 412 384 362

65 151 153 142 154

65 224 231 215 231

75 79 76 68 82

75 113 113 103 122

85 19 18 15 23

85 26 24 21 21

90 5 6 2

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONE LUMENS % LAMP % FIXT 00-030 568 23.7 32.6 00-040 927 38.6 53.1 00-060 1487 62.0 85.2 00-090 1746 72.8 100.0 90-180 0000 0.0 000.0 00-180 1746 72.8 100.0

ZONE LUMENS % LAMP % FIXT 00-030 885 24.6 32.9 00-040 1442 40.0 53.7 00-060 2301 63.9 85.7 00-090 2685 74.6 100.0 90-180 0000 0.0 000.0 00-180 2685 74.6 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 80 77 74 72 70 68 69 68 66 02 73 68 63 64 60 57 62 59 56 03 67 60 55 57 53 49 55 51 48 04 62 54 48 51 46 43 50 45 42 05 57 49 42 46 41 37 45 40 37 06 53 44 38 42 37 33 41 36 33 07 49 40 34 38 33 29 37 33 29 08 46 37 31 35 30 26 34 30 26 09 43 34 28 33 28 24 32 27 24 10 41 31 26 3O 25 22 30 25 22

01 82 79 76 74 72 70 71 69 68 02 75 70 65 66 62 59 63 60 58 03 69 62 56 59 54 51 57 53 50 04 64 55 49 53 48 44 51 47 43 05 59 50 44 48 42 38 46 42 38 06 55 45 39 43 38 34 42 37 34 07 51 41 35 40 34 30 39 34 30 08 47 38 32 36 31 27 35 31 27 09 44 35 29 34 28 25 33 28 25 10 42 32 27 31 26 23 30 26 23

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1902. 1973. 1944. 55 1523. 1558. 1453. 65 1187. 1202. 1116. 75 1014. 975. 873. 85 724. 686. 572.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2935. 3043. 3001. 55 2310. 2385. 2223. 65 1760. 1815. 1689. 75 1450. 1450. 1322. 85 991. 914. 800.

Ordering Information Explanation of Catalog Number. Example: SKS2GPK214UNVPG

P

K

Body Style:

Ceiling Type:

Side LensP = Frost White
Center LensK = Pattern 19

Lamp Quantity 2=2 Lamp

Lamp(By Others) 14 =T5 14W 24 =T5HO 24W (Nominal 24")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Grid T = Slot Grid

.156 Virgin Acyrlic Lens

no., ie(A)

Ballast Type:

SK Standard Skyway

SY For NYC Code – I.B.E.W. Manufactured

NK For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30. Specifications Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 1202 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.4%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.

Specifications (continuned) Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2009 a Philips Group Section 5/Folio MA12-12

Lightolier is a Philips group brand

Show 7 more labels / short text on this page
Skyway Recessed Fluorescent · Fixture · S = Static · Width · G = Standard · A = Air · Acrylic Lens
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier SKS2GPK214について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier SKS2GPK214に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier SKS2GPK214 取扱説明書(PDF)

2 ページ·312 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…