Page 1 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp T 5 or T5HO




5" (127mm)
2" max.
2" max.
(SKA Only)
G T
Exposed T-grid ceiling.
Exposed Slot T-grid ceiling


Drywall Kit (See Options)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
Drywall Kit, Catalog Number: FK92X2.
earthquake clip installed (lay-in grid)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 Lamp T 5 or T5HO
Model No. SKS2GPK214UNVPG LER = FP - 56.4 IW - 32.5 BF - 1.05 Comparative yearly lighting energy cost per
Model No. SKS2GPK224UNVPG LER = FP - 52.4 IW - 51.3 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.25
1000 lumens = $4.58


0 748 748 748
0 1153 1153 1153
5 743 742 742 71
5 1145 1145 1146 109
prismatic acrylic lens assembly. Ballast: ICN-2S28-SC Report is based on 1200 Lumens per lamp. Efficiency: 72.8% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 704 705 705 199
prismatic acrylic lens assembly. Ballast: ICN-2S24 Report is based on 1800 Lumens per lamp. Efficiency: 74.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 1087 1094 1101 309
25 633 643 669 299
25 977 1007 1055 467
35 533 578 612 358
35 822 901 954 557
45 405 420 414 323
45 625 648 639 497
55 263 269 251 237
55 399 412 384 362
65 151 153 142 154
65 224 231 215 231
75 79 76 68 82
75 113 113 103 122
85 19 18 15 23
85 26 24 21 21
90 5 6 2
90
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 568 23.7 32.6 00-040 927 38.6 53.1 00-060 1487 62.0 85.2 00-090 1746 72.8 100.0 90-180 0000 0.0 000.0 00-180 1746 72.8 100.0
ZONE LUMENS % LAMP % FIXT 00-030 885 24.6 32.9 00-040 1442 40.0 53.7 00-060 2301 63.9 85.7 00-090 2685 74.6 100.0 90-180 0000 0.0 000.0 00-180 2685 74.6 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 80 77 74 72 70 68 69 68 66 02 73 68 63 64 60 57 62 59 56 03 67 60 55 57 53 49 55 51 48 04 62 54 48 51 46 43 50 45 42 05 57 49 42 46 41 37 45 40 37 06 53 44 38 42 37 33 41 36 33 07 49 40 34 38 33 29 37 33 29 08 46 37 31 35 30 26 34 30 26 09 43 34 28 33 28 24 32 27 24 10 41 31 26 3O 25 22 30 25 22
01 82 79 76 74 72 70 71 69 68 02 75 70 65 66 62 59 63 60 58 03 69 62 56 59 54 51 57 53 50 04 64 55 49 53 48 44 51 47 43 05 59 50 44 48 42 38 46 42 38 06 55 45 39 43 38 34 42 37 34 07 51 41 35 40 34 30 39 34 30 08 47 38 32 36 31 27 35 31 27 09 44 35 29 34 28 25 33 28 25 10 42 32 27 31 26 23 30 26 23
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1902. 1973. 1944. 55 1523. 1558. 1453. 65 1187. 1202. 1116. 75 1014. 975. 873. 85 724. 686. 572.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2935. 3043. 3001. 55 2310. 2385. 2223. 65 1760. 1815. 1689. 75 1450. 1450. 1322. 85 991. 914. 800.
P
K
Body Style:
Ceiling Type:
Lamp Quantity 2=2 Lamp
Grid T = Slot Grid
.156 Virgin Acyrlic Lens
Ballast Type:
NK For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30. Specifications Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 1202 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.4%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.
Specifications (continuned) Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org