Page 1 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 or 3 Lamp T8




2" max.
2" max.
5" (127mm)
G T
Exposed T-grid ceiling.
Exposed Slot T-grid ceiling


(SKA Only)
Drywall Kit (See Options)
15-11/16" (398mm)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
Drywall Kit, Catalog Number: FK92X2.
earthquake clip installed (lay-in grid)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 or 3 Lamp T8
Model No. SKS2GPK217UNVHI LER = FP - 58.1 IW - 31.7 BF - 0.93 Comparative yearly lighting energy cost per
Model No. SKS2GPK317UNVH3 LER = FP - 46.8 IW - 46.6 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.13
1000 lumens = $5.13


0 845 845 845
0 1391 1391 1391
5 839 838 839 80
5 1384 1378 1381 131
prismatic acrylic lens assembly. Ballast: ICN-2P32-SC Report is based on 1400 Lumens per lamp. Efficiency: 70.7% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 796 797 801 225
prismatic acrylic lens assembly. Ballast: ICN-3P32-SC Report is based on 1400 Lumens per lamp. Efficiency: 72.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 1312 1309 1315 370
25 714 727 752 337
25 1175 1172 1166 539
35 602 648 695 405
35 984 952 956 602
45 459 477 474 367
45 720 714 732 553
55 297 308 287 270
55 447 475 435 412
65 171 175 162 175
65 260 274 249 269
75 89 86 79 94
75 140 131 125 145
85 21 24 17 26
85 33 35 28 39
90 7 7 3
90 12 13 5
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 642 22.9 32.4 00-040 1047 37.4 52.9 00-060 1684 60.1 85.1 00-090 1979 70.7 100.0 90-180 0000 0.0 000.0 00-180 1979 70.7 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1040 24.8 34.0 00-040 1642 39.1 53.7 00-060 2607 62.1 85.2 00-090 3060 72.9 100.0 90-180 0000 0.0 000.0 00-180 3060 72.9 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 78 75 72 70 68 66 67 66 64 02 71 66 61 62 59 56 60 57 54 03 65 59 53 55 51 48 53 50 47 04 60 52 47 50 45 41 48 44 41 05 56 47 41 45 40 36 44 39 36 06 52 43 37 41 36 32 40 35 32 07 48 39 33 37 32 29 36 32 28 08 45 36 30 34 29 26 33 29 26 09 42 33 27 32 27 23 31 26 23 10 39 30 25 29 25 21 29 24 21
01 80 77 74 72 70 68 69 68 66 02 74 68 64 64 61 58 62 59 56 03 68 61 55 57 53 49 55 52 49 04 62 54 48 51 47 43 50 46 42 05 58 49 43 47 42 38 45 41 37 06 53 44 38 42 37 33 41 37 33 07 50 40 34 39 34 30 38 33 30 08 46 37 31 36 31 27 35 30 27 09 44 34 29 33 28 24 32 28 24 10 41 32 26 31 26 22 30 25 22
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2156. 2240. 2226. 55 1720. 1783. 1662. 65 1344. 1375. 1273. 75 1142. 1103. 1014. 85 800. 914. 648.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3382. 3353. 3438. 55 2588. 2750. 2519. 65 2043. 2153. 1957. 75 1796. 1681. 1604. 85 1257. 1334. 1067.
P
17 K
Body Style:
Ceiling Type:
Lamp Quantity 2=2 Lamp 3=3 Lamp
Grid T = Slot Grid
.156 Virgin Acyrlic Lens
Ballast Type:
Ballast
NK For NYC Code – Local 3 Manufactured
1 or 2 Lamp Elec. T8 – C5* 0.80 1 - 3 Lamp Elec. T8 – C6* 0.81 LOL Dimming T8 PS* – *Instant Start Standard Other dimming options. Consult factory. NOTE: For T8 UNV, you must use HI OR H3 Ballast Code.
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30. Specifications Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 1375 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.6%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.
Specifications (continuned) Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org