Skyway SKS2GPK232 or 332

Page 1 of 2 2' x 4' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 or 3 Lamp T 8

  • Features
  • Aesthetically pleasing triple lens design.
  • Curved high light transmission frost white acrylic side lenses.
  • Clear acrylic conical prismatic center lens.
  • Internal reflector coated with 95% reflective white paint.
  • 75.3% efficient 2 Lamp 32 watt T8.
  • 75.4% efficient 3 Lamp 32 watt T8.
  • 5" deep body.
  • Black housing exterior for cooler ballast operating temperature.
  • Eyeleted heat removal vents in fixture ends.
  • Hemmed over side rails for maximum safety.
  • Fixture ends turned-in for safe handling.
  • Built-in earthquake clips (patent no. 5,072,344).
  • Door jamb finished black on four sides for positive light stop.
  • True mitered corner aluminum lens frame.
  • Spring loaded rooster head latches.
  • 18 gauge steel hinges.
  • Construction to meet NYC Code Requirements or Chicago Plenum is available.
Lightolier SKSGPK232 — Skyway SKS2GPK232 or 332 diagram (page 1)
図 1 · Skyway SKS2GPK232 or 332

Mounting Methods Dimensions

Lightolier SKSGPK232 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions

24" (610mm)

Lightolier SKSGPK232 — 24" (610mm) diagram (page 1)
図 3 · 24" (610mm)
Lightolier SKSGPK232 — 24" (610mm) diagram (page 1)
図 4 · 24" (610mm)

5" (127mm)

2" max.

2" max.

24" (610mm)

5" (127mm)

G T

Exposed T-grid ceiling.

Exposed Slot T-grid ceiling

Lightolier SKSGPK232 — 24" (610mm) diagram (page 1)
図 5 · 24" (610mm)
Lightolier SKSGPK232 — 24" (610mm) diagram (page 1)
図 6 · 24" (610mm)
Lightolier SKSGPK232 — 24" (610mm) diagram (page 1)
図 7 · 24" (610mm)

Air supply slots

(SKA Only)

Drywall Kit (See Options)

6" (152mm)

2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s

Drywall Kit, Catalog Number: FK92X4.

earthquake clip installed (lay-in grid)

39-1/4" (997mm)

47-31/32" (1218mm)

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2009 a Philips Group Section 5/Folio MA12-18

Lightolier is a Philips group brand

Show 8 more labels / short text on this page
15/16" or 9/16" · 15/16" or 9/16" · 24" · 24" · Skyway Fixture · Support (by others) · Drywall (by others) · 01/09
Page 2 of the Lightolier SKSGPK232 user manual — Lightolier is a Philips group brand
2ページ · クリックして拡大
2ページ

Skyway SKS2GPK232 or 332

Page 2 of 2 2' x 4' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 or 3 Lamp T8

Model No. SKS2GPK232UNVC5 LER = FP - 69.3 IW - 51.9 BF - 0.77 Comparative yearly lighting energy cost per

Model No. SKS2GPK332UNVH3 LER = FP - 70.9 IW - 87.0 BF - 0.88 Comparative yearly lighting energy cost per

1000 lumens = $3.46

CANDELA DISTRIBUTION

1000 lumens = $3.38

CANDELA DISTRIBUTION

Lightolier SKSGPK232 — CANDELA DISTRIBUTION diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Lightolier SKSGPK232 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 9

0.0 45.0 90.0 FLUX

Report NumberG2008169 Catalog Number: SKS2GPK232UNVC5 Lamps: (2) F32T8/ADV/841/ALTO Luminaire: Skyway Recessed 2' x 4' fixture
Report NumberG2008332 Catalog Number: SKS2GPK332UNVH3 Lamps: (3) F32T8/ADV/841/ALTO Luminaire: Skyway Recessed 2' x 4' fixture

0 1990 1990 1990

0 3104 3104 3104

5 1972 1975 1978 188

5 3082 3082 3092 293

prismatic acrylic lens assembly. Ballast: INC-2P32-LW-SC Report is based on 3100 Lumens per lamp. Efficiency: 75.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 45.600 21.600

15 1875 1891 1913 535

prismatic acrylic lens assembly. Ballast: ICN-3P32-SC Report is based on 3100 Lumens per lamp. Efficiency: 75.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 45.600 21.600

15 2940 2945 2951 831

25 1702 1765 1831 815

25 2672 2662 2625 1222

35 1464 1589 1647 979

35 2284 2184 2158 1382

45 1156 114 1063 867

45 1710 1657 1665 1284

55 732 714 643 630

55 1052 1099 990 955

65 406 401 354 400

65 608 639 565 626

75 205 185 170 207

75 323 296 284 333

85 48 35 31 46

85 90 74 66 88

90

90 15 16 8

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

COEFFICIENTS OF UTILIZATION –

ZONAL LUMEN SUMMARY

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONE LUMENS % LAMP % FIXT 00-030 1537 24.8 32.9 00-040 2516 40.6 53.9 00-060 4013 64.7 86.0 00-090 4666 75.3 100.0 90-180 0000 0.0 000.0 00-180 4666 75.3 100.0

ZONE LUMENS % LAMP % FIXT 00-030 2346 25.2 33.5 00-040 3728 40.1 53.2 00-060 5967 64.2 85.1 00-090 7014 75.4 100.0 90-180 0000 0.0 000.0 00-180 7014 75.4 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 83 80 77 75 73 71 72 70 69 02 76 70 66 66 63 60 64 61 58 03 70 63 57 59 55 51 57 54 50 04 64 56 50 53 48 44 52 47 44 05 60 51 44 48 43 39 47 42 39 06 55 46 39 44 38 34 43 38 34 07 51 42 35 40 35 31 39 34 31 08 48 38 32 37 31 28 36 31 28 09 45 35 29 34 29 25 33 28 25 10 42 33 27 31 26 23 31 26 23

01 83 80 77 75 73 71 72 70 68 02 76 70 66 66 63 60 64 61 58 03 70 63 57 59 55 51 57 53 50 04 64 56 50 53 48 44 51 47 44 05 60 50 44 48 43 39 47 42 38 06 55 46 39 44 38 34 42 38 34 07 51 42 35 40 35 31 39 34 30 08 48 38 32 37 31 28 36 31 28 09 45 35 29 34 29 25 33 28 25 10 42 33 27 31 26 23 31 26 23

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2572. 2478. 2365. 55 2008. 1958. 1764. 65 1511. 1493. 1318. 75 1246. 1124. 1033. 85 866. 632. 560.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3804. 3686. 3704. 55 2885. 3014. 2715. 65 2263. 2379. 2103. 75 1963. 1895. 1726. 85 1624. 1336. 1191.

Ordering Information Explanation of Catalog Number. Example: SKS2GPK232UNVHI

P

32 K

Body Style:

Ceiling Type:

Side LensP = Frost White
Center LensK = Pattern 19

Lamp Quantity 2=2 Lamp 3=3 Lamps

Lamp(By Others) 32 =T8 32W (Nominal 48")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Grid T = Slot Grid

.156 Virgin Acyrlic Lens

no., ie(A)

Ballast Type:

SK Standard Skyway

Ballast

SY For NYC Code – I.B.E.W. Manufactured

NK For NYC Code – Local 3 Manufactured

1 or 2 Lamp Elec. T8 – C5* 0.77 1 - 3 Lamp Elec. T8 – C6* 0.77 LOL Dimming T8 PS* – *Instant Start Standard Other dimming options. Consult factory. NOTE: For T8 UNV, you must use HI OR H3 Ballast Code.

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30. Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To reduce glare the average brightness at 65° shall not exceed 1511 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.1%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.

Specifications (continuned) Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2009 a Philips Group Section 5/Folio MA12-18

Lightolier is a Philips group brand

Show 7 more labels / short text on this page
Skyway Recessed Fluorescent · Fixture · S = Static · Width · G = Standard · A = Air · Acrylic Lens
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier SKSGPK232について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier SKSGPK232に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier SKSGPK232 取扱説明書(PDF)

2 ページ·166 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…