Page 1 of 2 4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12


2" (51mm)
2-1/2" (66mm)
TOP VIEW
7/8" K.O. (3)
1/2" K.O. (2)
1-13/16" (46mm) 1-1/16" (27mm)
1-1/16" (27mm)
SIDE VIEW
1-1/4" (32mm)
7/8" K.O. (4)
3-3/4" (95mm)

4-1/8" (105mm)
ONE LAMP

5-11/16" (145mm)
Job Information Type:
TWO LAMP
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 4-1/8" WIDE, 1-13/16" DEEP, 24", 36", 48" LENGTHS, 1 OR 2 LAMP, T8 OR T12
LER = FS - 69.9 Watts - 82 BF - 0.95 Comparative yearly lighting energy cost per 1000 lumens = $3.43

coefficients of utilization — zonal cavity method
REPORT NO.: G14162 DATE.: 8/14/91 CATALOG NO.: SM234HPF120LE LAMP(S): 2 F40 , EACH RATED 3150 LUMENS EFFICIENCY; 95.8% LUMINAIRE: SIDE MOUNTED STRIP, MAGNETIC WATTS: 82.0
CANDELA DISTRIBUTION FLUX 0.0 45.0 90.0 00 819 819 819 05 815 814 812 77 15 787 785 791 222 25 731 741 752 341 35 650 673 694 420 45 545 586 628 452 55 422 492 561 440 65 286 400 497 392 75 150 323 462 334 85 41 288 443 291 95 42 276 428 284

ZONAL LUMEN SUMMARY ZONE LUMENS %LAMP %FIXT 00-030 641 10.2 10.6 00-040 1061 16.8 17.6 00-060 1954 31.0 32.4 00-090 2971 47.2 49.3 90-180 3061 48.6 50.7 00-180 6033 95.8 100.0
LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE AVERAGE AVERAGE IN DEG 0-DEG 45-DEG 90-DEG 45 4703 3870 3855 55 4400 3589 3730 65 3916 3373 3728 75 3129 3348 4118 85 1918 4031 5055
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD
PERFORMANCE MAY DIFFER FROM LABORATORY PEFORMANCE.
SM
STRIP
Factor HPF=High Power
Factor BALLAST: 1 or 2 Lamp Mag. (T12) LE Standard Electro Magnetic (20 or 30 watts only) P
LAMP: (By Others) 17=(T8), 2' Length 20=T12, 2' Length 25=T8, 3' Length 30=T12, 3' Length 32=T8, 4' Length 34=T12, 4' Length
OPTIONS & ACCESSORIES FUSING: Internal fast-blow fusing.
SPECIFICATIONS: MATERIALS: Chassis parts are die-formed code gauge cold rolled steel, 1- 13/16" deep x 2-1/2" channel width. BALLAST: Cover–code gauge cold rolled steel, secured by quarter-turn latches. FINISH: Chassis exterior–baked white polyester enamel, minimum reflectance 86%. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc Listed.
SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: RF. STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").