Page 1 of 2 2'x2' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC 2 OR 3 LAMP, T8, 1-5/8" U LAMP OR 2' LAMP

F G plaster ceiling/flanged. (with regressed aluminum frame)
exposed T-grid ceiling. (with flat aluminum frame)



1/4" max.
24-1/8" 1-1/8" min. 3-3/4" max.

1-1/2" max.
15/16" or 1" 24"

drywall kit (see options) exposed T-grid ceiling (with flat steel frame)


Drywall Kit (See Options)
1/4" max.
1-1/2" max.
24" Ceiling Opening 24-5/16" x 24-5/16"
15/16" 15/16" or 1"
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2'x2' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC 2 OR 3 LAMP, T8, 1-5/8" U LAMP OR 2' LAMP
Luminaire Efficacy Rating LER-64.1 Watts-76.2 BF-0.88

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 75 72 69 67 65 63 65 63 62 2 69 63 59 60 57 54 58 55 53 3 63 56 51 53 49 46 52 48 45 4 58 51 45 48 44 40 46 43 39 5 54 46 40 43 39 35 42 38 35 6 50 41 36 39 35 31 38 34 31 7 46 38 32 36 31 28 35 31 28 8 43 34 29 33 28 25 32 28 25 9 40 32 26 31 26 23 30 26 23 10 38 29 24 28 24 21 28 24 21 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 51 55 62 69 49 53 59 66 20 30 45 48 53 58 41 45 50 55 20 40 42 44 48 52 36 40 44 49 20 60 38 41 44 47 32 36 39 44 30 20 53 57 61 67 51 55 59 65 30 30 46 49 52 57 42 46 50 54 30 40 41 44 47 50 37 40 44 47 30 60 38 41 42 45 33 36 38 42 30 80 36 39 40 43 31 33 35 38 40 20 54 58 62 67 53 57 61 66 40 30 47 50 53 57 44 48 51 55 40 40 42 45 47 50 38 42 45 48 40 60 38 41 42 45 34 37 38 42 40 80 37 39 39 42 32 34 35 38 40 100 36 38 38 40 31 32 33 35 60 30 48 51 54 58 46 50 52 56 60 40 43 46 48 51 40 43 46 49 60 60 39 41 42 45 35 37 39 42 60 80 37 39 39 42 32 34 35 38 60 100 36 37 37 40 31 32 33 35 100 40 45 48 50 53 44 47 49 52 100 60 41 43 44 47 38 40 41 45 100 80 39 40 40 43 35 37 37 40 100 100 37 38 38 40 33 34 34 36
SP
S
VA
FIXTURE
2=2 Lamp 3=3 Lamp
aluminum frame FA=Flat aluminum frame
BALLAST TYPE:
VA (virgin acrylic) standard (see options and
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot. PLASTER FRAME: Catalog Number PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VB (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc Listed.
Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS PERFORMANCE: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72. To prevent glare the VCP shall be not less than 35 either lengthwise or crosswise (at 100fc level), and the average brightness at 65° shall not exceed 3497 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.8%.