Calculite ® Incandescent Open Wall Washer T7032

Page 1 of 2 7 3/8” Aperture A21 / A23 / PS25

Lightolier T7032 — Calculite ® Incandescent Open Wall Washer T7032 diagram (page 1)
図 1 · Calculite ® Incandescent Open Wall Washer T7032

Top View

Flush 7 7/8" Overlap 8 5/8"

Molded Trim Ring Flush Trim (Molded Trim Ring Removed)

Overlap Self-Flange Matte White or Polished

Ceiling Cutout: 8" Dia.

Lightolier T7032 — Top View diagram (page 1)
図 2 · Top View
Reflector TrimsFrame-In KitLamp FinishWhite Self-FlangePolished Flush/White Self-Flange Molded Trim RingT701 Clear U702 GoldA21 150W A23 200W PS25 300W Wall WasherSpecular C Specular Glear T7032CLW old U7032GDWT7032CLP T7032CL U7032GDP U7032GD Corner Wall WasherSpecular C Specular Glear T7033CLW old U7033GDWT7033CLP T7033CL U7033GDP U7033GDT701 Clear U702 Gold Double Wall WasherSpecular C Specular Glear T7034CLW old U7034GDWT7034CLP T7034CL U7034GDP U7034GDT701 Clear U702 Gold

Features 1. Socket Cup: Die-cast aluminum cup effectively dissipates heat and assures lamps maintain proper optical alignment to reflector. Snaps onto reflector neck for easy tool-less installation. Can be adjusted without tools from inside or outside of fixture to accommodate three different lamp sizes. Contains medium base porcelain socket with nickel plated screw shell wired and No 18 SF1 leads to J-Box 2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4” or 1 1/2”lathing channels, or 1/2” (11/16" O.D.) EMT pipe (by others) or Lightolier accessory mounting bars. 3. Retaining Springs: Precision-tooled springs secure reflector housing to mounting frame for quick tool-less installation. 4. Insert Reflector: Alzak® aluminum, 16 ga., "cut-window" reflector allows light to pass to a separately contoured outer housing reflector. 50° visual cut-off to lamp and lamp image. Insert reflector contours provide even down- lighting. Direction of wall wash can be re-oriented after installation. Attaches with screws for simple installation and maintenance. Reflector supplied with white molded trim ring (field paintable); or self-flanged reflec- tor, matte white flange or flange finish to match reflector. 5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. Provides flangeless trim in plaster ceiling. 8. Wall Wash Reflector/Housing: Specular clear or gold 16 ga. Alzak® alu- minum to match insert reflector. Attaches to mounting frame with springs. Detachable for inspection from below fixture. Reflector provides even wall wash. Must be installed before ceiling is finished.

Accessories / Options 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Wood Joist Mtg. Bars 7994 (set of 2) Existing Ceiling Clips 7998 (set of 2) Step Down Transformer 7997 (see separate specification sheet) Chicago Air Plenum LC (add suffix to Frame-in Kit)

Electrical UL Listed for a maximum of 8 No. 12, 75°C through branch circuit conductors, or 60°C supply conductors for end of run.

Labels UL Listed for damp locations, I.B.E.W.

Alzak® is a registered trademark of ALCOA.

Lightolier T7032 — Top View diagram (page 1)
図 3 · Top View
  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902

Other Reflector Finish Options Consult Factory

Show 4 more labels / short text on this page
13 1/2" · 4 7/8" · 11 1/2" · 12 1/2"
Page 2 of the Lightolier T7032 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® Incandescent Open Wall Washer T7032

7 3/8” Aperture A21 / A23 / PS25

3' 4' 5' 6'

1 44 41 44 37 29 37 34 24 34 33 18 33 2 59 62 59 49 40 49 43 32 43 41 24 41 3 67 74 67 57 50 57 50 35 50 47 26 47 4 72 72 72 58 53 58 50 40 50 46 32 46 5 67 73 67 53 53 53 44 44 44 40 34 40 6 60 62 60 47 50 47 38 42 38 33 35 33 7 51 62 51 41 42 41 32 38 32 27 31 27 8 41 51 41 34 35 34 27 32 27 23 27 23 9 36 45 36 31 31 31 24 28 24 21 23 21 10 32 36 32 27 29 27 23 25 23 20 21 20 11 28 32 28 25 26 25 21 23 21 19 19 19 12 26 29 26 22 24 22 19 21 19 18 18 18 13 23 26 23 22 23 22 18 20 18 17 16 17 14 21 25 21 20 21 20 16 20 16 15 15 15

Distance From Ceiling (FT.)

Footcandles on wall from multiple units Clear cone, 300W PS-25

WALL

WALL

DOUBLE WALLWASHER

WALLWALL WALL WALL INSIDE CORNER WASHER WALLWASHERWALL INSIDE CORNER WALLWASHER

UNITS 4 FEET FROM WALL

4' 28 2623 23 2321 19 2120 15 20 38 3631 32 3127 24 2725 20 25 41 4337 35 3733 26 3331 22 31 47 4640 41 4036 29 3634 23 34 47 5041 41 4137 32 3734 26 34 48 4942 41 4237 34 3734 27 34 46 4537 40 3732 33 3228 29 28 41 4034 36 3428 31 2825 27 25 35 3729 32 2924 28 2421 25 21 34 3227 29 2722 26 2219 22 19 31 2925 25 2521 22 2118 20 18 28 2622 23 2219 21 1916 18 16 25 2420 22 2017 19 1716 16 16 22 2218 19 1816 17 1615 14 15

Distance From Ceiling (FT.)

47 f.c. 26 f.c.

EXAMPLE: With multiple clear cone units, using 300W PS-25 lamps, located 3' from wall and 6' on center, (matching downlights 6' on center), the illumination on the wall 3' down from the ceiling is 47 f.c. beneath fixtures and 26 f.c. between fixtures.

UNITS 5 FEET FROM WALL

5' 6' 7' 8' 9' 10'

1 19 20 19 17 17 17 16 15 16 15 13 15 14 11 14 13 9 13 2 26 27 26 23 24 23 21 19 21 19 17 19 18 15 18 17 12 17 3 29 30 29 26 26 26 23 22 23 21 18 21 20 16 20 19 14 19 4 32 32 32 28 29 28 25 26 25 22 22 22 20 20 20 19 17 19 5 33 36 33 30 31 30 27 25 27 25 21 25 23 18 23 23 15 23 6 34 35 34 30 30 30 27 27 27 24 23 24 23 20 23 22 17 22 7 33 35 33 29 30 29 26 27 26 23 22 23 22 20 22 21 17 21 8 32 35 32 28 29 28 25 26 25 22 22 22 20 20 20 19 17 19 9 29 32 29 25 27 25 22 25 22 19 22 19 17 19 17 16 17 16 10 27 30 27 23 26 23 20 23 20 18 20 18 16 18 16 15 17 15 11 24 26 24 21 24 21 19 20 19 17 18 17 15 17 15 13 15 13 12 21 24 21 19 21 19 17 17 17 15 16 15 13 15 13 10 14 10 13 19 22 19 17 19 17 16 16 16 14 14 14 12 14 12 9 13 9 14 17 20 17 15 15 15 14 13 14 13 12 13 10 12 10 8 11 8

Distance From Ceiling (FT.)

Footcandle values are averaged and rounded off and tables are based on a minimum of five units. Conversion Factors: 300W PS-25 units with gold cone, F.C. x 0.90. 200W A-23 units: clear cone, F.C. x 0.65; gold cone, F.C. x 0.55. 150W A-21 units: clear cone, F.C. x 0.45; gold cone, F.C. x 0.40.

Candlepower WALL WASH SIDEWALL WASH SIDEDistribution Downlight Spacing Ratio = 1.3 For even wall washing use a maximum of 2 to 1 spacing (distance between fixture ÷ distance to wall). DOWNLIGHT SIDE

Coefficients of Utilization % Effective Ceiling Cavity Reflectance

80 70 50 30 10 0

50 30 10%Wall Reflectance50 30 10 50 30 1050 30 1050 30 10

1 2 3 4 5 6 7 8 9 10

.81 .80 .78 .80 .78 .77 .77 .75 .74 .74 .72 .72 .71 .70 .70 .68 .76 .73 .71 .75 .72 .70 .72 .70 .69 .70 .69 .67 .68 .67 .67 .65 .71 .67 .66 .70 .67 .66 .68 .67 .66 .67 .65 .64 .67 .64 .62 .61 .67 .64 .62 .67 .63 .61 .65 .63 .60 .64 .62 .60 .63 .60 .59 .56 .64 .59 .57 .63 .59 .56 .62 .59 .53 .60 .58 .56 .59 .57 .55 .54 .60 .56 .53 .59 .56 .53 .59 .56 .52 .57 .55 .52 .57 .54 .52 .51 .56 .52 .49 .56 .52 .49 .55 .51 .49 .54 .51 .48 .53 .50 .48 .48 .53 .49 .47 .52 .48 .47 .52 .48 .47 .51 .48 .46 .50 .48 .46 .45 .49 .46 .43 .49 .46 .43 .48 .45 .42 .48 .45 .42 .47 .44 .42 .41 .47 .43 .39 .46 .42 .39 .46 .42 .39 .45 .42 .39 .45 .42 .39 .38

ROOM CAVITY RATIO

20% Floor Cavity Reflectance Conversion Factor: 200W A-23 (Clear) and 150W A-21 (Clear): F.C. x 1.0; 300W PS-25, 200W A-23 and 150W A-21 (Gold): F.C. x 0.9

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division)
  • A0902
Show 6 more labels / short text on this page
Units 3 Feet · From Wall · 6' · 6' · 3' · 3'
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier T7032について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier T7032に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier T7032 取扱説明書(PDF)

2 ページ·123 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…