Page 1 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 12 CELL (3x4) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.
24" 24" 9/16" 15/16" or 1"

Air supply slots (VPA only)
3-1/2” (89mm) 15-11/16" (398mm)
concealed Z-spline ceiling.
direct concealed two directional T-grid ceiling. (see options for splay trim).


1/4" max.
1-1/8" min. 3-3/4" max.
1-7/8" max.
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
F
plaster ceiling/flanged.
drywall kit (see options).
Job Name:


Cat. No.:
Lamp(s):
Volts/Ballast:
1-1/8" min. 3-3/4" max.

Page 2 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 12 CELL (3x4) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
LER = FP - 49.0 IW - 47.0 BF - 0.90 Comparative yearly lighting energy cost per 1000 lumens = $4.89

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 70 68 67 64 63 62 62 61 60 2 66 63 60 60 58 56 58 56 55 3 62 58 55 55 53 51 54 52 50 4 59 53 49 51 48 46 50 47 45 5 55 49 45 47 44 41 46 43 41 6 51 45 41 44 40 37 43 39 37 7 48 41 37 40 36 34 39 36 33 8 44 37 33 36 33 30 36 32 30 9 41 34 29 33 29 26 32 29 26 10 38 31 26 30 26 23 29 26 23 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 89 93 92 83 98 98 98 93 20 30 89 93 92 83 98 99 98 94 20 40 89 93 92 84 98 99 98 94 20 60 90 94 92 84 98 99 98 94 30 20 89 93 92 86 98 99 98 94 30 30 90 94 92 87 98 99 98 94 30 40 90 94 92 87 98 99 98 94 30 60 90 94 92 87 98 99 98 94 30 80 90 94 92 87 98 99 98 95 40 20 89 93 92 86 98 99 98 94 40 30 90 94 92 87 98 99 98 94 40 40 90 94 92 87 98 99 98 94 40 60 90 94 93 87 98 99 98 95 40 80 90 94 93 87 98 99 98 95 40 100 90 94 93 87 98 99 98 95 60 30 90 94 92 87 98 99 98 94 60 40 90 94 93 87 98 99 98 95 60 60 90 94 93 87 98 99 98 95 60 80 90 94 93 87 98 99 98 95 60 100 90 94 93 87 98 99 98 95 100 40 90 94 93 87 98 99 98 95 100 60 90 94 93 87 98 99 98 95 100 80 90 94 93 87 98 99 98 95 100 100 90 94 93 88 98 99 98 95
VP
P
P
(lay-in T bar) F=Flanged
NUMBER OF
LAMP TYPE/
Z spline and plaster frame T=Slot grid or
two-directional concealed T (see options)
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS (continued) AIR HANDLING: (VPA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends. MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 637, 32, 13 and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.