Page 1 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 16 CELL (4x4) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE


exposed T-grid ceiling. T
exposed slot T-grid ceiling.


1/4" max.
1-1/2" max. 1-7/8" max.
24" 24" 15/16" or 1" 9/16"
Air supply slots (VRA only)

concealed Z-spline ceiling.
direct concealed two directional T-grid ceiling. (see options for splay trim).


1/4" max.
1-1/8" min. 3-3/4" max.
1-7/8" max.
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
F
plaster ceiling/flanged.
drywall kit (see options).
Job Name:


Cat. No.:
Lamp(s):
Volts/Ballast:
1-1/8" min. 3-3/4" max.

Page 2 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 16 CELL (4x4) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
LER = FP - 42.0 IW - 57.6 BF - 90.3 Comparative yearly lighting energy cost per 1000 lumens = $5.71
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 58 57 55 53 52 51 51 51 50 2 55 52 49 49 47 46 48 46 45 3 51 47 44 45 43 41 44 42 40 4 48 44 40 42 39 37 41 38 36 5 45 40 37 39 36 33 38 35 33 6 42 37 33 36 33 30 35 32 30 7 40 34 31 33 30 28 32 30 28 8 37 32 28 31 28 25 30 27 25 9 35 29 26 29 26 23 28 25 23 10 33 27 24 27 24 22 26 24 22 visual comfort probability (rated lumens per lamp 3150.)

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 95 93 90 82 99 98 98 95 20 30 96 94 91 85 99 99 98 96 20 40 96 94 93 87 99 99 98 96 20 60 96 94 93 88 99 99 98 96 30 20 95 93 92 86 99 98 98 95 30 30 96 95 93 87 99 99 98 96 30 40 96 95 94 89 99 99 98 96 30 60 96 95 94 90 99 99 98 96 30 80 96 94 94 90 99 99 98 96 40 20 95 94 92 86 99 99 98 96 40 30 96 95 93 88 99 99 98 96 40 40 96 95 94 90 99 99 98 96 40 60 96 94 94 91 99 99 98 96 40 80 96 94 94 91 99 99 98 96 40 100 96 94 94 91 99 99 98 97 60 30 96 95 93 88 99 99 98 96 60 40 96 94 94 90 99 99 98 96 60 60 96 95 94 91 99 99 98 97 60 80 96 95 94 91 99 99 98 97 60 100 96 95 94 91 99 99 98 97 100 40 96 94 94 90 99 99 98 97 100 60 96 95 94 91 99 99 98 97 100 80 96 95 94 91 99 99 98 97 100 100 96 95 94 91 99 99 99 97
VR
S
6U
(lay-in T bar) F=Flanged
NUMBER OF
Iridescence Semi-specular (standard) P=Low
LAMP TYPE/
no, ie: (GLR) BALLAST TYPE: 1-2 Lamp Mag. T12 LE
Z spline and plaster frame T=Slot grid or
6"U Lamp T8 OR T12 (Nominal 24")
two-directional concealed T (see options)
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures, Order Catalog Number: S2CTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10.) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS (continued) AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends. MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .57 with a spacing to mounting ratio of 1.2 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 96 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 293, 104, and 77 cande- las per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1737.