Page 1 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (3x6) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE


exposed T-grid ceiling. T
exposed slot T-grid ceiling.


1/4" max.
1-1/2" max. 1-7/8" max.
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
24" 24" 15/16" or 1" 9/16"

Air supply slots (VRA only)
concealed Z-spline ceiling.
direct concealed two directional T-grid ceiling. (see options for splay trim).


1/4" max.
1-1/8" min. 3-3/4" max.
1-7/8" max.
F
plaster ceiling/flanged.
drywall kit (see options).
Job Name:


Cat. No.:
Lamp(s):
Volts/Ballast:
1-1/8" min. 3-3/4" max.

Page 2 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (3x6) PARABOLIC LOUVER STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
LER = FP - 55.0 WATTS - 85 BF - 0.85 Comparative yearly lighting energy cost per 1000 lumens = $4.36
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 72 70 68 66 65 63 64 62 61 2 67 64 60 60 58 56 58 56 54 3 63 58 54 55 52 49 53 51 48 4 58 52 48 50 46 44 49 46 43 5 54 48 43 46 42 39 45 41 38 6 51 44 39 42 38 35 41 37 35 7 47 40 35 38 34 31 38 34 31 8 44 37 32 35 31 28 35 31 28 9 42 34 29 33 29 26 32 28 26 10 39 31 27 30 26 24 30 26 24 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 90 86 79 79 98 96 97 93 20 30 92 88 83 78 98 97 97 94 20 40 92 89 86 81 98 97 97 94 20 60 93 90 87 83 98 97 97 94 30 20 90 86 84 82 98 97 97 92 30 30 92 89 86 81 98 97 97 94 30 40 93 90 88 83 98 97 97 94 30 60 93 91 89 85 98 97 97 94 30 80 93 91 90 86 98 97 97 94 40 20 90 86 84 85 98 97 97 92 40 30 93 90 86 84 98 97 97 93 40 40 93 91 88 84 98 97 97 93 40 60 94 91 90 86 98 97 97 94 40 80 94 91 90 87 98 97 97 94 40 100 94 91 90 88 98 97 97 94 60 30 93 90 86 83 98 97 97 93 60 40 93 91 89 84 98 97 97 93 60 60 94 92 90 87 98 97 97 94 60 80 94 92 90 88 98 97 97 94 60 100 94 92 91 88 98 97 97 94 100 40 93 91 89 84 98 97 97 94 100 60 94 92 90 87 98 97 97 94 100 80 94 92 91 88 98 97 97 95 100 100 93 92 91 89 97 97 97 95
VR
P
(lay-in T bar) F=Flanged
Iridescence Semi-specular (standard) P=Low
no, ie: (GLR) BALLAST TYPE: 1 & 2 Lamp Mag. LE
NUMBER OF
DUAL “V” REFLECTOR
LAMP TYPE/
WIDTH
Z spline and plaster frame T=Slot grid or
32 =T8 34 =T12
two-directional concealed T (see options)
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES PLASTER FRAME: Catalog Number: PF24. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures, Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X4. Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS (continued) AIR HANDLING: (VRA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends. MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec- tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .70 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual comfort probability) shall not be less than 94 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 304, 147, and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.