JA
Lightolier logo
公式取扱説明書

Lightolier VRB Series

2 ページ·349 KB·インテリア家具・調度品·PDF·EN
Lightolier VRB Series
目次 25セクション VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4' · LOUVER CONFIGURATIONS DIMENSIONS · 5-1/2" (140mm) · 12" (305mm) · … 表示非表示
Page 1 of the Lightolier VRB Series user manual — 16 Cell 24 Cell
1ページ · クリックして拡大
1ページ

VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4'

Page 1 of 2 1'x4' SURFACE BOX FLUORESCENT, 3" DEEP PARABOLIC LOUVER IES RP1 FOR NORMAL VDT USE, 1 OR 2 LAMP T8, T12

  • Features
  • 1 lamp 8 or 12 cell, 2 lamp 16 or 24 cell meet IES RP1 for lighting VDT areas with normal use.
  • Only 5-1/2" deep body.
  • Efficiency 66% (1 lamp 8 cell).
  • 1.9 spacing mounting ratio.
  • Welded 20 gauge steel body.
  • 45° mitered corners (body).
  • 3" deep cell aluminum parabolic louver.
  • Spring-loaded latches.
  • Reversible louver hinge.
  • Door jamb with integral positive light stop.
  • Flush end K.O.s for smooth appearance (at end of row or individual).
  • Matches Vision Smart 1'x4' recessed.
  • Low-iridescence, semi-specular aluminum louver, standard.
  • Vertical grain on louver eliminates reflected lamp images on cross baffle.
  • Louver has polyethylene dust guard.
  • Meets NYC Code requirements.
Lightolier VRB Series — VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4' diagram (page 1)
図 1 · VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4'

LOUVER CONFIGURATIONS DIMENSIONS

Lightolier VRB Series — LOUVER CONFIGURATIONS DIMENSIONS diagram (page 1)
図 2
Lightolier VRB Series — LOUVER CONFIGURATIONS DIMENSIONS diagram (page 1)
図 3

5-1/2" (140mm)

5-1/2" (140mm)

12" (305mm)

12" (305mm)

9/32" mounting hole

3/16" x 5/8" K.O.

4" (102mm)

Lightolier VRB Series — 4" (102mm) diagram (page 1)
図 4 · 4" (102mm)

1-3/16" (30mm)

20" (508mm)

8 Cell 12 Cell

2" (51mm)

7/8" K.O. (4)

12" (305mm) 7/8" dia. K.O. within 1-7/8" dia. K.O.

48" (1219mm)

Job Information Type:

Job Name:

Cat. No.:

16 Cell 24 Cell

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-72 REV. A

• · 5-7/8" (149mm)

Page 2 of the Lightolier VRB Series user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4'

Page 2 of 2 1'x4' SURFACE BOX FLUORESCENT, 3" DEEP PARABOLIC LOUVER IES RP1 FOR NORMAL VDT USE, 1 OR 2 LAMP T8, T12

LER = FP - 25.9 IW - 63.8 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $9.26

PHOTOMETRY MODEL NO. VRB1S8LS132120SO

Lightolier VRB Series — PHOTOMETRY MODEL NO. VRB1S8LS132120SO diagram (page 2)
図 5

coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 73 71 69 67 65 64 64 63 62 2 68 64 60 60 57 55 58 56 54 3 63 57 52 54 50 47 52 49 47 4 58 51 46 48 44 41 47 43 41 5 53 46 40 44 39 36 42 39 36 6 49 41 36 40 35 32 38 34 31 7 46 37 32 36 31 28 35 31 28 8 42 34 29 33 28 25 32 28 25 9 40 31 26 30 26 22 29 25 22 10 37 29 24 28 23 20 27 23 20 visual comfort probability

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 90 87 82 86 88 85 80 78 20 30 91 89 86 84 90 87 82 78 20 40 92 90 88 86 90 88 85 80 20 60 93 91 89 88 90 88 86 83 30 20 91 89 84 84 88 88 82 79 30 30 92 91 87 82 90 90 84 78 30 40 93 92 89 84 90 90 86 80 30 60 94 93 90 86 90 90 87 83 30 80 94 93 90 86 90 90 87 83 40 20 91 89 85 85 88 88 84 80 40 30 93 91 88 83 90 90 86 80 40 40 94 92 80 85 90 90 88 82 40 60 94 93 91 87 90 90 88 84 40 80 94 92 91 87 90 90 88 84 40 100 94 92 91 87 90 90 88 84 60 30 93 91 88 85 90 90 86 81 60 40 93 92 90 87 90 90 88 83 60 60 94 93 91 88 90 90 88 85 60 80 94 93 91 88 91 90 88 85 60 100 94 93 91 88 91 90 88 85 100 40 93 92 90 87 90 90 88 83 100 60 94 93 91 88 91 90 88 85 100 80 94 93 91 89 91 90 88 85 100 100 94 93 91 89 91 90 88 86

ORDERING INFORMATION Explanation of Catalog Number. Example: VRB1S8LS132120SOGLR

VR

B

S

S

VR 3" Deep Pre- anodized Aluminum

FIXTURE

NUMBER OF

WHITE REFLECTOR

LAMP/ FIXTURE LENGTH:

WIDTH:

CELLS: 8= 1 row of 8 cells 12= 1 row of 12 cells 16= 2 rows of 8 cells 24= 2 rows of 12 cells

32=T8 34=T12 (Nominal 48")

VOLTAGE120 or 277
OPTIONSAdd appropriate suffix to cat-
alog no., ie( GLR )

BALLAST TYPE: 1 or 2 Lamp Mag. T12 LE

BODY STYLE:

CEILING

LOUVER FINISHL = Low-iridescence

LAMP QUANTITY:

TYPES= Surface

Semi-specular P= Low-iridescence

1 lamp 2 lamp

OPTIONS & ACCESSORIES FUSING: Internal fast-blow fusing.

SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel with 45° mitered corners welded and turned in edges for safe handling. LOUVER: Pre-anodized aluminum (Coilzak® or equal). FINISH: Louver—semi-specular low iridescence, pre-anodized reflector sheet. Cavity—white baked acrylic minimum reflectance 86%, Phosphate undercoat- ing. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL listed.

SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is required). Catalog Number: ASC6 CSP (6"), ASC18 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

SPECIFICATIONS PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71 with a spacing to mounting ratio of 1.9 perpendicular to the lamp. To meet IES RP-1 recommended (basic) requirements for VDT areas the VCP (visual comfort probability) shall not be less than 90 either crosswise or length- wise and the maximum average brightness at 65°, 75° and 85° shall not exceed 592, 109 and 81 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 671.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-72 REV. A
Show 6 more labels / short text on this page
room cavity ratio · luminaries lengthwise · luminaries crosswise · Louver · Surface Box · Specular
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier VRB Seriesについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier VRB Seriesに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier VRB Series 取扱説明書(PDF)

2 ページ·349 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…