Page 1 of 2 2'x4' RECESSED FLUORESCENT


G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)

24" 24" 15/16" or 1"
TELECONFERENCE LIGHTING RECOMMENDATIONS 1. I.E.S. recommends 50 maintained footcandles for telecon- ferencing. 2. 3000K lamps with C.R.I. of 82 suggested for better skin tone. 3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to the wall that the viewing screen is on. 4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram). 5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use wall lighting luminaires where nec- essary. 5:1 maximum luminance ratio suggested. NOTE: For wall lighting, request Folio K20-05.
Job Name:

6' Min.
Cat. No.:
Lamp(s):
Lamp Direction End of Fixture
Volts/Ballast:

Page 2 of 2 2'x4' RECESSED FLUORESCENT
LER = FP - 54.6 IW - 83.5 BF - 0.89 Comparative yearly lighting energy cost per 1000 lumens = $4.39

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 67 65 63 61 60 59 59 58 57 2 63 59 56 56 54 52 54 52 51 3 58 54 50 51 48 46 50 47 45 4 55 49 45 47 44 41 46 43 40 5 51 45 40 43 39 37 42 39 36 6 48 41 37 40 36 33 39 35 33 7 45 38 33 37 33 30 36 32 30 8 42 35 31 34 30 27 33 30 27 9 39 32 28 31 28 25 31 27 25 10 37 30 26 29 26 23 29 25 23 visual comfort probability (rated lumens per lamp 2850.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 97 96 96 92 90 86 85 84 20 30 97 96 96 92 91 87 83 81 20 40 97 96 96 92 91 88 84 80 20 60 97 96 96 93 91 88 86 82 30 20 97 96 96 92 90 86 88 85 30 30 97 96 96 92 91 87 86 82 30 40 98 96 96 93 91 88 86 81 30 60 98 96 96 93 91 88 88 82 30 80 97 96 96 93 91 88 88 82 40 20 97 96 96 92 90 87 88 88 40 30 98 96 96 93 91 87 87 84 40 40 98 97 96 93 91 88 87 83 40 60 97 97 97 93 91 88 88 84 40 80 97 97 97 93 91 88 88 84 40 100 98 97 97 93 91 88 88 84 60 30 98 97 97 93 91 87 87 84 60 40 97 97 97 93 91 88 87 83 60 60 97 97 97 93 91 88 88 84 60 80 97 97 97 93 91 88 88 84 60 100 98 97 97 93 91 88 88 84 100 40 97 97 97 93 91 88 87 83 100 60 97 97 97 94 91 88 88 84 100 80 97 97 97 94 91 88 88 84 100 100 97 97 97 94 91 89 88 84
VT
S
PK
Blank=Standard N=NYC Code
LAMP QUANTITY:
2=2 Lamp 3=3 Lamp 4=4 Lamp LAMP TYPE/
(lay-in T bar) T= Slot Grid
INTEGRATED
WIDTH
SHIELDING
FIXTURE LENGTH:
BALLAST TYPE:
Other dimming options consult factory.
OPTIONS & ACCESSORIES RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory. DRYWALL KIT: Order Catalog Number: FK92X4. (Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal). Lens–High quality glare control lens with square based male conical prisms. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc listed.