Page 1 of 2 2'x2' RECESSED FLUORESCENT


G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.
24" 24" 15/16" or 1" 9/16"

TELECONFERENCE LIGHTING RECOMMENDATIONS 1. I.E.S. recommends 50 maintained footcandles for teleconferencing. 2. 3000K lamps with C.R.I. of 82 suggested for better skin tone. 3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpen- dicular to the wall that the viewing screen is on. 4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram). 5. Side and back walls should be illuminated to reduce contrast vs. other vertical sur- faces. Use wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested.
2"x2-1/2" access plate with two K.O.s (7/8" dia.)

Job Name:
Lamp Direction End of Fixture
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2'x2' RECESSED FLUORESCENT
PHOTOMETRY MODEL NO. VTS2GPK3FT120X3
LER = FP - 42.9 WATTS - 102.6 BF - 0.85 Comparative yearly lighting energy cost per 1000 lumens = $5.59

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 62 60 59 57 55 54 55 54 53 2 58 55 52 52 50 48 50 49 47 3 54 50 47 48 45 43 46 44 42 4 51 46 42 44 41 39 43 40 38 5 48 42 38 40 37 35 39 37 34 6 45 39 35 37 34 31 36 33 31 7 42 36 32 35 31 29 34 31 29 8 39 33 29 32 29 26 31 28 26 9 37 31 27 30 27 24 29 26 24 10 35 29 25 28 25 22 27 24 22 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 94 92 89 81 82 77 76 75 20 30 95 93 92 85 84 78 72 70 20 40 96 93 92 87 86 80 73 69 20 60 96 94 93 85 87 82 76 70 30 20 94 91 89 81 82 79 80 76 30 30 95 92 91 85 86 80 75 71 30 40 95 93 91 85 88 83 76 69 30 60 95 93 93 85 89 84 79 70 30 80 95 94 93 85 89 86 81 70 40 20 94 92 90 81 83 79 80 79 40 30 95 92 92 85 86 80 77 74 40 40 96 93 92 85 99 93 78 72 40 60 96 94 93 85 89 85 80 73 40 80 95 94 93 85 90 86 82 73 40 100 95 94 94 85 90 87 84 73 60 30 95 93 92 85 86 80 77 74 60 40 96 93 92 86 88 83 78 72 60 60 96 94 93 86 90 85 81 74 60 80 95 94 93 86 90 87 83 75 60 100 95 94 94 86 90 88 85 75 100 40 96 93 92 87 88 83 78 73 100 60 96 94 92 87 90 86 81 74 100 80 95 94 93 87 91 88 84 75 100 100 95 94 94 87 91 89 85 76
VT
S
PK
Blank=Standard N=NYC Code
(lay-in T bar) T= Slot Grid
2=2 Lamp 3=3 Lamp LAMP TYPE/
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal). Lens–High quality glare control lens with square based male conical prisms. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc listed.