JA
Lightolier logo
公式取扱説明書

Lightolier VTS2GPK3FT

2 ページ·708 KB·インテリア家具・調度品·PDF·EN
Lightolier VTS2GPK3FT
目次 18セクション VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT · Page 1 of 2 2'x2' RECESSED FLUORESCENT · MOUNTING METHODS DIMENSIONS · exposed T-grid ceiling. T · … 表示非表示
Page 1 of the Lightolier VTS2GPK3FT user manual — TELECONFERENCING ORIENTATION
1ページ · クリックして拡大
1ページ

VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT

Page 1 of 2 2'x2' RECESSED FLUORESCENT

Lightolier VTS2GPK3FT — VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT diagram (page 1)
図 1
  • Features
  • Provides soft vertical illumination for comfortable televising of participants.
  • Shields the camera from light sources and eliminates glare on the projection screen.
  • Integrated specular parabolic blades and prismatic acrylic lens assembly for directional brightness control.
  • 77 minimum VCP in rooms with less than 10' ceiling (3 lamp TT5).
  • Spring-loaded latches.
  • Concealed “T” hinges.
  • Louver/lens assembly with positive light stop.
  • Four earthquake clips standard.
  • UL-Listed twin knockout access plate.
  • Construction to meet NYC Code Requirements and Chicago Plenum Code is available.
Lightolier VTS2GPK3FT — VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT diagram (page 1)
図 2

MOUNTING METHODS DIMENSIONS

G

exposed T-grid ceiling. T

exposed slot T-grid ceiling.

Lightolier VTS2GPK3FT — MOUNTING METHODS DIMENSIONS diagram (page 1)
図 3
Lightolier VTS2GPK3FT — MOUNTING METHODS DIMENSIONS diagram (page 1)
図 4
Lightolier VTS2GPK3FT — MOUNTING METHODS DIMENSIONS diagram (page 1)
図 5

1/4" max.

1-1/2" max. 1-7/8" max.

24" 24" 15/16" or 1" 9/16"

Lightolier VTS2GPK3FT — MOUNTING METHODS DIMENSIONS diagram (page 1)
図 6

TELECONFERENCE LIGHTING RECOMMENDATIONS 1. I.E.S. recommends 50 maintained footcandles for teleconferencing. 2. 3000K lamps with C.R.I. of 82 suggested for better skin tone. 3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpen- dicular to the wall that the viewing screen is on. 4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram). 5. Side and back walls should be illuminated to reduce contrast vs. other vertical sur- faces. Use wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested.

2"x2-1/2" access plate with two K.O.s (7/8" dia.)

Lightolier VTS2GPK3FT — MOUNTING METHODS DIMENSIONS diagram (page 1)
図 7

Job Information Type:

Job Name:

Lamp Direction End of Fixture

Cat. No.:

Lamp(s):

Volts/Ballast:

TELECONFERENCING ORIENTATION

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-10
Show 7 more labels / short text on this page
6" (152mm) · 24" (610mm) · 23-7/8" (606mm) · 15-11/16" (398mm) · 5" (127mm) · 6' · Viewing Screen
Page 2 of the Lightolier VTS2GPK3FT user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT

Page 2 of 2 2'x2' RECESSED FLUORESCENT

PHOTOMETRY MODEL NO. VTS2GPK3FT120X3

LER = FP - 42.9 WATTS - 102.6 BF - 0.85 Comparative yearly lighting energy cost per 1000 lumens = $5.59

Lightolier VTS2GPK3FT — VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT diagram (page 2)
図 8

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 62 60 59 57 55 54 55 54 53 2 58 55 52 52 50 48 50 49 47 3 54 50 47 48 45 43 46 44 42 4 51 46 42 44 41 39 43 40 38 5 48 42 38 40 37 35 39 37 34 6 45 39 35 37 34 31 36 33 31 7 42 36 32 35 31 29 34 31 29 8 39 33 29 32 29 26 31 28 26 9 37 31 27 30 27 24 29 26 24 10 35 29 25 28 25 22 27 24 22 visual comfort probability (rated lumens per lamp 3150.)

G02032 VTS2GPK3FT120X3

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 94 92 89 81 82 77 76 75 20 30 95 93 92 85 84 78 72 70 20 40 96 93 92 87 86 80 73 69 20 60 96 94 93 85 87 82 76 70 30 20 94 91 89 81 82 79 80 76 30 30 95 92 91 85 86 80 75 71 30 40 95 93 91 85 88 83 76 69 30 60 95 93 93 85 89 84 79 70 30 80 95 94 93 85 89 86 81 70 40 20 94 92 90 81 83 79 80 79 40 30 95 92 92 85 86 80 77 74 40 40 96 93 92 85 99 93 78 72 40 60 96 94 93 85 89 85 80 73 40 80 95 94 93 85 90 86 82 73 40 100 95 94 94 85 90 87 84 73 60 30 95 93 92 85 86 80 77 74 60 40 96 93 92 86 88 83 78 72 60 60 96 94 93 86 90 85 81 74 60 80 95 94 93 86 90 87 83 75 60 100 95 94 94 86 90 88 85 75 100 40 96 93 92 87 88 83 78 73 100 60 96 94 92 87 90 86 81 74 100 80 95 94 93 87 91 88 84 75 100 100 95 94 94 87 91 89 85 76

ORDERING INFORMATION Explanation of Catalog Number. Example: VTS2GPK3FT120X3GLR

VT

S

PK

Blank=Standard N=NYC Code

BODY STYLE:

CEILING TYPEG = Grid

LAMP QUANTITY

VOLTAGE120 or 277 OPTIONS: Add appropriate suffix to catalog

(lay-in T bar) T= Slot Grid

2=2 Lamp 3=3 Lamp LAMP TYPE/

VTVideo Teleconference

FIXTURE

no, ie( GLR ) BALLAST TYPE:

WIDTH

FIXTURE LENGTH6U =6"U Lamp T8 (2 Lamp Only) FT = Twin Tube T5

INTEGRATED

SHIELDING

Other dimming options. Consult factory.

OPTIONS & ACCESSORIES RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal). Lens–High quality glare control lens with square based male conical prisms. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc listed.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-10
Show 6 more labels / short text on this page
room cavity ratio · luminaries lengthwise · luminaries crosswise · S=Static · Luminaire · (Nominal 24")
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier VTS2GPK3FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier VTS2GPK3FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier VTS2GPK3FT 取扱説明書(PDF)

2 ページ·708 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…