Dominaire II WB Series 417/2FT

Page 1 of 2 Surface Wraparound Fluorescent 14" Wide X 3" Deep X 24" Length, T8 OR TT5 Lamps

  • Features
  • Excellent for lighting Cafeterias, Small Offices, Corridors, Kitchens and Family Rooms.
  • Step back housing for an apparent depth of 1½".
  • Completely assembled with setup ends with lamp holders.
  • Only 3" total depth.
  • Prismatic virgin acrylic lens - 14" wide.
  • 69% efficient (4 Lamp T8).
  • 72.1% efficient (2 Lamp TT5).
  • Luminous catadioptic end caps.
  • Self-leveling lens opens and hinges from either side.
  • Off-center 7/8” K.O. for flush mount to T-grid ceiling.
  • For surface mounting only.
Lightolier WB Series 2FT — Dominaire II WB Series 417/2FT diagram (page 1)
図 1 · Dominaire II WB Series 417/2FT

Features Dimensions

Lightolier WB Series 2FT — Features Dimensions diagram (page 1)
図 2 · Features Dimensions
Lightolier WB Series 2FT — Features Dimensions diagram (page 1)
図 3 · Features Dimensions
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 3A/Folio H90-15 10/07
Page 2 of the Lightolier WB Series 2FT user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Dominaire II WB Series 417/2FT

Page 2 of 2 Surface Wraparound Fluorescent 14" Wide X 3" Deep X 24" Length, T8 OR TT5 Lamps

Model No. WB2B417UNVH4 LER = FP - 61.5 IW - 54.3 BF - 0.88 Comparative yearly lighting energy cost per

Model No. WB2B2FTUNVIB LER = FP - 58.7 IW - 69.6 BF - 0.90 Comparative yearly lighting ene gy cost per

1000 lumens = $3.90

CANDELA DISTRIBUTION

CANDELA DISTRIBUTION

Lightolier WB Series 2FT — CANDELA DISTRIBUTION diagram (page 2)
図 4

1000 lumens = $4.09

0.0 45.0 90.0 FLUX 0 1380 1380 1380 5 1373 1376 1378 131 15 1321 1345 1364 380 25 1218 1282 1327 589 35 1058 1168 1216 721 45 800 949 971 700 55 427 558 524 468 65 271 288 309 282 75 163 163 204 177 85 61 76 100 83 90 28 39 65 95 30 38 69 50 105 44 48 95 64 115 37 63 64 55 125 26 40 45 35 135 22 36 38 26 145 17 29 32 17 155 13 21 24 9 165 10 13 15 4 175 7 8 8 1 180 7 7 7

Lightolier WB Series 2FT — CANDELA DISTRIBUTION diagram (page 2)
図 5

0.0 45.0 90.0 FLUX 0 1664 1664 1664 5 1652 1663 1667 159 15 1596 1645 1685 465 25 1480 1607 1694 738 35 1296 1508 1550 914 45 986 1141 1067 832 55 538 620 537 525 65 332 330 317 318 75 196 190 219 203 85 74 87 106 94 90 38 46 71 95 43 46 79 61 105 61 61 97 75 115 41 64 48 54 125 31 43 43 37 135 29 40 40 30 145 23 34 35 20 155 18 26 28 12 165 13 16 20 5 175 10 11 11 1 180 9 9 9

Report NumberG2007050 Lamp: (4) F17T8 Luminaire: Dominaire II WB with clear
Report NumberG2007068 Lamp: (2) TT5 40W Luminaire: Dominaire II WB with clear

prismatic lens Ballast: B432IUNVHP-A (Triad) Report is based on 1375 Lumens per lamp. Efficiency: 69.0% CIE Type - Direct Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90

prismatic lens Ballast: C240PUNVHP-B (Triad) Report is based on 3150 Lumens per lamp. Efficiency: 72.1% CIE Type - Direct Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

1 74 71 69 65 63 62 62 60 59 2 68 63 58 58 55 52 55 52 50 3 63 56 51 52 48 44 49 46 43 4 58 50 44 46 42 38 44 40 37 5 53 45 39 42 37 33 40 36 33 6 49 40 35 38 33 29 36 32 29 7 46 37 31 35 30 26 33 29 26 8 43 34 28 32 27 24 30 26 23 9 40 31 25 29 25 21 28 24 21 10 37 29 23 27 22 19 26 22 19 ZONE LUMENS % LAMP % FIXT 0- 30 1100 20.0 29.0 0- 40 1821 33.1 48.0 0- 60 2989 54.4 78.8 0- 90 3532 64.2 93.1 90-120 170 3.1 4 5 90-130 205 3.7 5.4 90-150 249 4 5 6.6 90-180 263 4.8 6.9 0-180 3795 69.0 100.0

1 75 75 72 69 67 65 65 64 62 2 72 66 62 61 58 55 58 55 53 3 66 59 53 55 50 47 52 48 46 4 61 53 47 49 44 41 47 43 40 5 56 47 41 44 39 36 42 38 35 6 52 43 37 40 35 31 39 34 31 7 48 39 33 37 32 28 35 31 28 8 45 36 30 34 29 25 32 28 25 9 42 33 27 31 26 23 30 26 22 10 39 30 25 29 24 21 28 23 20 ZONE LUMENS % LAMP % FIXT 0- 30 1361 21 6 30 0 0- 40 2275 36 1 50 1 0- 60 3633 57 7 80 0 0- 90 4248 67.4 93 5 90-120 190 3 0 4 2 90-130 227 3 6 5 0 90-150 276 4.4 6 1 90-180 294 4 7 6 5 0-180 4542 72 1 100 0

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4751. 5496. 5487. 55 3037. 3833. 3481. 65 2497. 2526. 2585. 75 2228. 2063. 2403. 85 1714. 1826. 2098.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 5649. 6348. 5770. 55 3682. 4075. 3395. 65 2931. 2752. 2504. 75 2547. 2261. 2403. 85 1931. 1906. 2002.

Ordering Information Explanation of Catalog Number. Example: WB2B417UNVHI

WB

B

UNV

DOMINAIRE II:

Fixture Length:

Fixture Width:

Lamp Quantity 4 = 4 Lamp T8 2 = 2 Lamp TT5

Lamp(By Others) 17 = T8 17W FT = TT5 40W

White Surface Wrap Fluorescent

2 = 2' Length

B = 14" Wide

VoltageUNV =120-277
OptionsAdd appropriate suffix to catalog no.,
ie(GLR) Consult factory for additional options

Ballast Type:

Options/Accessories Electrical Wiring Options: Consult factory for Emergency pack and dimming options. Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) End Caps: Injection molded catadioptic end caps separate from lens. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Internal slow blow fusing: SUFFIX: GMF.

Specifications Performance: In an installation of 4 lamp 17W luminaries in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 2585 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 64.1%. Materials: Chassis parts are die-formed code gauge cold rolled steel. Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventive undercoating. Lens: One-piece extruded virgin acrylic prismatic bottom and side walls.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 3A/Folio H90-15

with White Body · (Nominal 24")

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier WB Series 2FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier WB Series 2FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier WB Series 2FT 取扱説明書(PDF)

2 ページ·112 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…