Page 1 of 2 High Performance, 2', Recessed Wallwasher/Accent Light

  • One Twin-Tube T5 Lamp Features
  • Low iridescent specular reflective system for precise controlled light output.
  • Evenly lights vertical surfaces or displays.
  • 87% energy savings vs. incandescent.
  • 3,150 lumen Biax type lamp requires fewer fixtures to provide the same wall illumination as a 150 watt incandescent wallwasher.
  • 20,000 hours lamp life requires less maintenance than incandescent.
  • Fits all lay-in grid ceiling systems.
  • One-piece body and adjustable integral hanger for easy, quick installation.
  • UL-Listed access plate.
  • Meets NYC Code requirements.
Lightolier WLRN124120SB — Wal-Lyter WLRN124120SB diagram (page 1)
図 1 · Wal-Lyter WLRN124120SB
Lightolier WLRN124120SB — Wal-Lyter WLRN124120SB diagram (page 1)
図 2 · Wal-Lyter WLRN124120SB

Pattern Number 5,146,393

Features Dimensions

Lightolier WLRN124120SB — Pattern Number 5,146,393 diagram (page 1)
図 3 · Pattern Number 5,146,393
Lightolier WLRN124120SB — Pattern Number 5,146,393 diagram (page 1)
図 4 · Pattern Number 5,146,393

20,000 hour Biax type lamp (22-1/2" long)

4 low iridescent specular aluminum reflectors

2" x 3" access plate

Mounting Methods

narrow grid. slot grid

Lightolier WLRN124120SB — Mounting Methods diagram (page 1)
図 5 · Mounting Methods
Lightolier WLRN124120SB — Mounting Methods diagram (page 1)
図 6 · Mounting Methods
Lightolier WLRN124120SB — Mounting Methods diagram (page 1)
図 7 · Mounting Methods

Job Information Type:

Lightolier WLRN124120SB — Job Information Type: diagram (page 1)
図 8 · Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K10-10 Rev. A 9/05
Show 10 more labels / short text on this page
Ballast Wall · 23-3/8"6" · 17-5/8" · 2-7/8" · 22-1/16" opening · 1-1/2" · 1-3/16" · standard grid · adjustable integral hanger · 1-1/2"
Page 2 of the Lightolier WLRN124120SB user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Wal-Lyter WLRN124120SB

Page 2 of 2 High Performance, 2', Recessed Wallwasher/Accent Light

One Twin Tube T5 Lamp

Photometry Model No. WLRN124120SB

LER = FP - 42.8 IW - 47 BF - 0.95 Comparative yearly lighting energy cost per 1000 lumens = $5.61

Lightolier WLRN124120SB — Wal-Lyter WLRN124120SB diagram (page 2)
図 9 · Wal-Lyter WLRN124120SB

coefficients of utilization — zonal cavity method

RF20 20 20 RC80 50 30 RW70 50 30 50 30 10 50 30 10 1 2 ratio 3 4 cavity 5 6 7 room 8 9 1074 71 68 66 64 62 64 62 60 67 61 57 58 54 51 55 52 49 61 54 48 51 46 42 49 45 41 56 47 41 49 39 35 43 38 35 51 41 35 39 34 29 38 33 29 46 37 30 35 29 25 33 29 25 42 32 26 31 25 21 30 25 21 39 29 23 27 22 18 26 22 18 35 26 19 24 19 15 24 19 15 33 23 17 22 17 13 21 16 13
Ceiling 8' 7' 6' 5' 4' 3' 2' 1' FloorINDIVIDUAL WAL-LYTER 0' 1' 2' 3' 4' 5' 6' 7' 8'MULTIPLE UNITS 04' 6'CONTINUOUS ROW 0' 1' 2' 3' 4' 5' 6' 7' 8' 76 67 48 25 14 08 5 4 3 64 68 48 29 17 10 7 5 4 47 44 36 24 17 12 8 6 4 33 34 29 24 14 10 8 6 5 26 28 23 23 14 11 8 6 5 19 21 29 17 12 9 8 6 5 15 16 15 13 11 9 8 6 5 13 12 11 11 10 8 7 6 5107 104 102 104 107 86 79 63 50 63 79 86 102 104 106 104 102 78 75 67 58 67 75 78 085 086 088 086 085 63 62 57 48 57 62 63 066 074 074 974 066 49 50 48 48 48 50 49 059 065 062 065 059 42 45 42 40 42 45 42 048 053 056 053 048 35 36 37 34 37 36 35 042 044 046 044 042 31 31 31 26 31 31 31 038 037 036 037 038 27 26 26 22 26 26 27204 204 209 208 212 208 209 204 204 201 203 208 208 212 208 208 203 201 165 166 173 172 177 172 173 166 165 132 142 140 148 145 148 140 142 132 113 124 121 130 126 130 121 124 113 096 100 104 106 109 106 104 100 096 080 082 088 088 093 088 088 082 080 067 068 074 074 079 074 074 068 067

Ordering Information Explanation of Catalog Number. Example: WLRN124120SBGLR

WL

R

N

Wal-LyterLow iridescent
ReflectorN = Low iridescent

Length:

2=24" Watts: 1=18 Watts 2=24 Watts 4=40 Watts 5=50 Watts 6=55 Watts

Voltage120 or 277
OptionsAdd appropriate suffix to catalog
no, ie(GLR)

Ballast Type:

Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF. Lens: .187, pattern 19 lens. Catalog Number: WLRKIT CSP (to be field installed). Radio Interference Filter: To order one RIF per fixture,Suffix: R. To order one RIF per ballast, Suffix: B. Electrical/Wiring Options: Consult factory. Fluorescent Emergency Lighting System: Factory-installed emergency power bat- tery pack with charger and inverter. Suffix: EM. Drywall Frame: Catalog Number: WL2DF/UNV.

Lightolier WLRN124120SB — Ordering Information Explanation of Catalog Number. Example: WLRN124120SBGLR diagram (page 2)
図 10 · Ordering Information Explanation of Catalog Number.…

Specifications Materials: Chassis parts are die-formed 20 gauge cold rolled steel with integral adjustable hanger clamp. Reflectors–low iridescent specular aluminum are standard. Finish: Chassis exterior–phosphate undercoating, baked white acrylic enamel. Reflector–low iridescent specular IS standard. Lens: Virgin acrylic .187 pattern 19 with square based male conical prisms (rotates for easy lamp replacement). Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.

optional drywall frame WL2DF/UNV.

Job Information Type:

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section5/Folio K10-10 Rev. A
Show 4 more labels / short text on this page
Recessed · Lamps · specular wallwash · specular aluminum standard
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier WLRN124120SBについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier WLRN124120SBに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier WLRN124120SB 取扱説明書(PDF)

2 ページ·872 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…