目次 10セクション Wal-Lyter WLRN244120SB · Page 1 of 2 High Performance, 4', Recessed Wallwasher/Accent Light · Features Dimensions · Mounting Methods · … 表示非表示
Page 1 of the Lightolier WLRN244120SB user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Wal-Lyter WLRN244120SB

Page 1 of 2 High Performance, 4', Recessed Wallwasher/Accent Light

  • Two Twin-Tube T5 Lamps Features
  • Low iridescent specular reflective system for precise controlled light output.
  • Evenly lights vertical surfaces or displays.
  • 87% energy savings vs. incandescent.
  • 3,150 lumen Biax type lamp requires fewer fixtures to provide the same wall illumination as a 150 watt incandescent wallwasher.
  • 20,000 hours lamp life requires less maintenance than incandescent.
  • Fits all lay-in grid ceiling systems.
  • One-piece body and adjustable integral hanger for easy, quick installation.
  • UL-Listed access plate.
  • Meets NYC Code requirements.
Lightolier WLRN244120SB — Wal-Lyter WLRN244120SB diagram (page 1)
図 1 · Wal-Lyter WLRN244120SB

Features Dimensions

Lightolier WLRN244120SB — Features Dimensions diagram (page 1)
図 2 · Features Dimensions
Lightolier WLRN244120SB — Features Dimensions diagram (page 1)
図 3 · Features Dimensions

20,000 hour Biax type lamp (22-1/2" long)

4 low iridescent specular aluminum reflectors

2" x 3" access plate

Mounting Methods

narrow grid. slot grid

Lightolier WLRN244120SB — Mounting Methods diagram (page 1)
図 4 · Mounting Methods
Lightolier WLRN244120SB — Mounting Methods diagram (page 1)
図 5 · Mounting Methods
Lightolier WLRN244120SB — Mounting Methods diagram (page 1)
図 6 · Mounting Methods

Job Information Type:

Lightolier WLRN244120SB — Job Information Type: diagram (page 1)
図 7 · Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K10-12 Rev. A 9/05
Show 10 more labels / short text on this page
Ballast Wall · 23-3/8"6" · 17-5/8" · 2-7/8" · 22-1/16" opening · 1-1/2" · 1-3/16" · standard grid · adjustable integral hanger · 1-1/2"
Page 2 of the Lightolier WLRN244120SB user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Wal-Lyter WLRN244120SB

Page 2 of 2 High Performance, 4', Recessed Wallwasher/Accent Light

Two Twin Tube T5 Lamps

Photometry Model No. WLRN244120SB

LER = FP - 47.5 IW - 85 BF - 0.95 Comparative yearly lighting energy cost per 1000 lumens = $5.05

Lightolier WLRN244120SB — Wal-Lyter WLRN244120SB diagram (page 2)
図 8 · Wal-Lyter WLRN244120SB

coefficients of utilization — zonal cavity method

RF20 20 20 RC80 50 30 RW70 50 30 50 30 10 50 30 10 1 2 ratio 3 4 cavity 5 6 7 room 8 9 1073 70 67 65 63 61 63 61 59 66 61 56 57 53 50 55 52 49 60 53 47 50 45 42 48 44 41 55 47 40 44 39 35 42 38 35 50 41 34 39 33 29 37 33 29 46 36 30 34 29 25 33 28 25 42 32 26 31 25 21 30 25 21 38 29 22 27 22 18 26 21 18 35 25 19 24 19 15 23 19 15 32 23 17 22 17 13 21 16 13

FOOTCANDLES ON WALL Fixtures 3 feet from wall to outside trim on lamp side of fixture

Ceiling 8' 7' 6' 5' 4' 3' 2' 1' FloorINDIVIDUAL WAL-LYTER 0' 1' 2' 3' 4' 5' 6' 7' 8'MULTIPLE UNITS 0 6' 111. 101. 75.5 47.8 28.3 18.1 13.2 10.4 0.87 113. 104. 81.7 55.7 35.5 23.5 16.6 12.5 09.8 86.4 81.0 66.9 49.8 34.8 24.6 17.7 13.4 10.4 62.5 59.1 51.4 41.6 31.9 24.3 18.4 13.9 16.7 50.5 48.6 42.9 35.6 28.7 22.6 18.0 14.3 11.1 39.7 38.5 34.9 30.0 25.1 20.6 16.9 14.1 11.4 31.1 30.3 28.1 25.0 21.7 18.5 15.7 13.4 11.1 24.2 23.6 22.5 20.8 18.7 16.5 14.6 12.8 11.0124. 119. 104. 95.4 104. 119. 124. 130. 127. 117. 111. 117. 127. 130. 104. 106. 102. 100. 102. 106. 104. 81.1 83.5 83.2 83.2 83.2 83.4 81.1 68.8 71.3 71.6 71.3 71.6 71.3 68.8 56.8 59.2 60.0 59.9 60.0 59.2 56.8 47.0 48.8 49.7 50.0 49.7 48.8 47.0 38.8 40.2 41.1 41.5 41.1 40.2 38.8
0Ceiling 8' 7' 6' 5' 4' 3' 2' 1' FloorMULTIPLE UNITS 8'CONTINUOUS ROW 0' 1' 2' 3' 4' 5' 6' 7' 8' 120. 111. 88.6 65.7 56.5 65.8 88.6 111. 120. 124. 117. 98.4 79.0 70.9 79.1 98.4 117. 124. 97.7 94.8 84.7 74.4 69.6 74.4 84.7 94.8 97.7 74.1 73.5 69.9 66.0 63.8 66.0 69.9 73.5 74.1 62.6 63.4 61.2 58.3 57.3 58.3 61.1 63.4 62.6 51.9 53.0 52.1 50.6 50.2 50.6 52.0 53.1 51.9 43.0 44.1 43.9 43.4 43.2 43.4 43.9 44.0 43.0 35.7 36.6 37.0 37.2 37.2 37.2 37.0 36.6 35.7181. 182. 183. 183. 184. 183. 183. 182, 181. 200. 201. 203. 201. 200. 173. 175. 176. 177. 177. 177. 176. 175, 173. 143. 146. 147. 148. 148. 148. 147. 146. 143. 125. 128. 129. 130. 130. 130. 129. 128. 125. 108. 110. 111. 112. 113. 112. 111. 110. 108. 91.9 03.0 05.2 05.9 96.3 95.9 95.2 93.9 91.9 78.7 80.3 81.4 82.1 82.5 82.0 81.4 80.3 78.7

Ordering Information Explanation of Catalog Number. Example: WLRN244120SBGLR

WL

R

Wal-LyterLow iridescent
Recessed ReflectorN = Low iridescent

Length:

4=48" Watts: 1=18 Watts 2=24 Watts 4=40 Watts 5=50 Watts 6=55 Watts

Voltage120 or 277 Options: Add appropriate suffix to catalog

specular aluminum standard K = Pattern 19 virgin

no, ie(GLR)

Ballast Type:

acrylic lens installed at factory

Options/Accessories Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF. Lens: .187, pattern 19 lens. Catalog Number: WLRKIT-4 CSP to be field installed. Radio Interference Filter: To order one RIF per fixture, Suffix: R. To order one RIF per ballast, Suffix: B. Electrical/Wiring Options: Consult factory. Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter. Suffix: EM. Drywall Frame: Catalog Number: WL4DF/UNV.

Lightolier WLRN244120SB — Ordering Information Explanation of Catalog Number. Example: WLRN244120SBGLR diagram (page 2)
図 9 · Ordering Information Explanation of Catalog Number.…

Specifications Materials: Chassis parts are die-formed 20 gauge cold rolled steel with integral adjustable hanger clamp. Reflectors–low iridescent specular aluminum are standard. Finish: Chassis exterior–phosphate undercoating, baked white acrylic enamel. Reflector–low iridescent specular is standard. Lens: Virgin acrylic .187 pattern 19 with square based male conical prisms (rotates for easy lamp replacement). Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.

optional drywall frame WL4DF/UNV.

Job Information Type:

  • Lightolier a Genlyte Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section5/Folio K10-12 Rev. A

Lamps · specular wallwash

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier WLRN244120SBについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier WLRN244120SBに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier WLRN244120SB 取扱説明書(PDF)

2 ページ·744 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…