AUT OMA TIC UPPER ARM Blood Pressure Monitor Model 1131 F ea tures: • Dual Person Memor y Zones • 50 Memories for each zone • Average for Last 3 Memories • Date and Time Stamp • One T ouch Operation T able of Contents: Introduction .........
2 Introduction Blood pressure measurements determined with Lumiscope Model 1131 are equivalent to those obtained by a trained obser ver using cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or Automated Sphygmomanometers.
3 Quick Read Measuring T echnology This monitor uses trend-setting Quick Read T echnology to detect your blood pressure. With one touch of a button, the device will automatically start to inflate and determine your blood pressure by analysis of your pressure oscilla tions.
4 Blood Pressure Standard The W orld Health Organization (WHO) has developed a blood pressure standard, according to which areas of lo w- and high-risk blood pressure are identified. This standard, however , is a general guideline and blood pressures var y between different people, age groups, etc.
5 Display Explanation Display: Icons: Memory Zone 1: Appears when the monitor is opera ted in memor y zone 1 Memory Zone 2: Appears when the monitor is opera ted in memor y zone 2 Weak Batter y Mark: .
Installing Battery 1. Press do wn and lift the batter y cover in the direction of the arro w to open the batter y compartment. 2. Install or replace 4 “AA ” sized ba tteries in the batter y compartment according to the indications inside the compartment.
7 Applying the arm cuff 1. Plug in the cuff connecting tube into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff through the D-ring of the cuff. 3. Put your left arm through the cuff loop. The "OK" range indication should be positioned closer to yourself with the rubber tube pointing in the direction of your arm.
Measurement Procedure 1. Press the User-Switching key to select Memor y Zone 1 or Memor y Zone 2. After a memor y zone is selected, press the button to reset the monitor so it can start measurement in the chosen memor y zone. 2. Press the button. All digits will light up, checking the display functions.
9 Measurement Procedure 4. When the measurement is completed, the cuff will automatically defla te. Systolic, diastolic and pulse will be sho wn simultaneously on the LCD screen. The measurement is then automatically stored into the pre-designated memory zone.
10 Recalling V alues from Memory 1. The Monitor has two Memor y Zones (1 and 2). Each zone can store up to 50 measurements. 2. T o read memor y values from a selected Memor y Zone, use the “User -Switching Key” to select a Memor y Zone (1 or 2) from which you want to recall values from.
11 Clearing V alues from Memory 1. Press the User-Switching key to select the memory zone 1 or memor y zone 2. 2. Continue to press and hold the “M” key for approxima tely 5 seconds, and the data in the pre- designated memor y zone will be erased automa tically .
T ime Adjustment 1. T o adjust the date/ time in the monitor , press the key . The display will show a blinking number sho wing the month. 2. Change the month by pressing the “ ” Key . Each press will increase the number by one in a cycling manner .
13 Helpful Tips Here are a few helpful tips to help you obtain more accurate readings: • Do not measure your blood pressure immediately after consuming a large meal. Wait a t least one hour after ea ting to take a measurement. • Do not smoke or drink alcohol before measuring your blood pressure.
14 T roubleshooting If an y abnormality should arise during use, please check the following points. Symptom No display when the ON/OFF/ST ART key is pressed EE mark sho wn on display or the blood pres.
15 Cautionary Notes: 1. The unit contains high-precision assemblies. Therefore, avoid extreme temperatures, humidity , and direct sunlight. Avoid dropping or strongly shocking the main unit, and protect it from dust. 2. Clean the blood pressure monitor bod y and the cuff carefully with a slightly damp, soft cloth.
16 Specifications: Measurement Method : Oscillometric Measurement Range : Pressure: 20~280mmHg; Pulse: 40~180 beats/ minute Pressure Sensor : Semi conductor Accuracy : Pressure: ± 3mmHg; Pulse: ± 5%.
17 T wo-Y ear Limited W arranty: Lumiscope guarantees this product free from defects in ma terial and workmanship for a period of two years from the da te of purchase, except as noted below: This Lumi.
デバイスLumiscope 1131の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lumiscope 1131をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLumiscope 1131の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lumiscope 1131の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lumiscope 1131で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lumiscope 1131を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLumiscope 1131の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lumiscope 1131に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLumiscope 1131デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。