MajesticメーカーCVR42の使用説明書/サービス説明書
ページ先へ移動 of 28
STR/CVR Series W oodburning Fireplace For Models: STR33 STR36 STR42 CVR36 CVR42 For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use.
2 STR/CVR Series W oodbur ning Fireplaces 7412961 Safety Information PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
3 STR/CVR Series W oodbur ning Fireplaces 7412961 STR Series Woodburning Fireplace Fig. 1 STR Series specifications and framing. 12" 9 " A D E 36" 21" 37" 7 .
4 STR/CVR Series W oodbur ning Fireplaces 7412961 FP701 STR/CVR Series W oodburning Fireplace Fig. 3 STR/CVR Parts Identification. FP701 STR/CVR Parts ID 5/18/98 STR Fireplace CVR Fireplace Gas Line .
5 STR/CVR Series W oodbur ning Fireplaces 7412961 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
6 STR/CVR Series W oodbur ning Fireplaces 7412961 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ " 25 ¹⁄₄.
7 STR/CVR Series W oodbur ning Fireplaces 7412961 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
8 STR/CVR Series W oodbur ning Fireplaces 7412961 Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
9 STR/CVR Series W oodbur ning Fireplaces 7412961 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materi- als.
10 STR/CVR Series W oodbur ning Fireplaces 7412961 Ceiling Chimney Hole/ Possible Obstructions The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney cen- ter point.
1 1 STR/CVR Series W oodbur ning Fireplaces 7412961 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ " (38mm), al- lowing the remainder to extend in front of firebox.
12 STR/CVR Series W oodbur ning Fireplaces 7412961 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together .
13 STR/CVR Series W oodbur ning Fireplaces 7412961 Locate Chimney Centerpoint on Roof Use same procedure detailed in locating centerpoint of the flue system. Drive a nail up through roof at the centerpoint. This will determine center point on outside of the roof.
14 STR/CVR Series W oodbur ning Fireplaces 7412961 W ARNING: DO NOT P ACK REQUIRED AIR SP ACES WITH INSULA TION OR OTHER MA TERIALS. Mark an outline of the roof hole around the center of the point nail.
15 STR/CVR Series W oodbur ning Fireplaces 7412961 MA81 rev . 8/5/97 1 " Ref. Combustible materials are permitted within a shaded area shown in Figure 23, titled Minimum W all Clearances. * * * MA81 Fig. 22 Combustible mantel clearances.
16 STR/CVR Series W oodbur ning Fireplaces 7412961 Side W all Protection All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible material.
17 STR/CVR Series W oodbur ning Fireplaces 7412961 W ARNING: HEARTH EXTENSION MUST BE IN- ST ALLED IN ACCORDANCE WITH FIGURES 24 AND 25. Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.
18 STR/CVR Series W oodbur ning Fireplaces 7412961 Example of Determining Hearth Extension Equivalents T o determine the thickness required for any new mate- rial: COMMON MA TERIALS AND F ACT ORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.
19 STR/CVR Series W oodbur ning Fireplaces 7412961 Installing Line for Gas Logs Majestic Fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas ap- pliance. (CFM Corporation manufactures a wide variety of gas logs for use in Majestic fireplaces.
20 STR/CVR Series W oodbur ning Fireplaces 7412961 5a 1, 2, 3 4a 6 7 a b c d 8 9 10 1 1 961 CVR parts 5/17/00 djt 5b 4b e 12 13 14 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
21 STR/CVR Series W oodbur ning Fireplaces 7412961 961 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 5 1, 2, 3 4 6 7 a b c d 8 9 10 1 1 961 STR parts 5/16/00 djt 12 STR33/36/42 SERIES Ref.
22 STR/CVR Series W oodbur ning Fireplaces 7412961 Gl ass Door Bi-Fold door set Brushed Brass finish 36GDKBB - STR36, CVR36 42GDKBB - STR42, CVR42 Black finish 36GDKBK - STR36 42GDKBK - STR42 Polish.
23 STR/CVR Series W oodbur ning Fireplaces 7412961 Chimney Components Round T op T ermination Round termination to be used with SK8 chimney RL TSK8 system. (Flashing not included.) Round T op T ermination Round termination to be used with 1 1CF chimney RL TCF1 1 system.
24 STR/CVR Series W oodbur ning Fireplaces 7412961 Firestop Required at each floor level of chimney SKFS2A — SK8 installation. (Plus attic on multi-story installation.
25 STR/CVR Series W oodbur ning Fireplaces 7412961.
26 STR/CVR Series W oodbur ning Fireplaces 7412961.
27 STR/CVR Series W oodbur ning Fireplaces 7412961 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIR.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスMajestic CVR42の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Majestic CVR42をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMajestic CVR42の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Majestic CVR42の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Majestic CVR42で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Majestic CVR42を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMajestic CVR42の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Majestic CVR42に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMajestic CVR42デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。