RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE OTL Report No. 116-F-36-5 B-VENT MPB-33/35/40/45 SERIES MODELS A French manual is available upon request. Order P/N 850,033CF Ce manuel d’installation est disponible en francais, simplement en faire la demande.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 T ABLE OF CONTENTS Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .......................... Page 2 Location .
3 Electronic Models - Electronic models have a fi xed rate gas valve. Input of electronic models is shown in T able 2: Millivolt Models with Manually-Modulated Gas Valve Natural Gas Propane Gas Model.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 In selecting the location, the aesthetic and func- tional use of the appliance are primary concerns.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 5 F E B D C G T op View FRAMING SP ACERS (T op and Sides and Rear) Front View 3 (76) A J H Flue Outlet For B-Vent Connection OPTIONAL ELECTRICAL INLET.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 FRAMING SPECIFICA TIONS Figure 7 Figure 9 Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or fi nishing with other thickness materi- als, calculations will need to be made.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 7 The fi replace should be secured to the side framing members using the unit's nailing fl anges - two at the top and bottom on each side of the fi replace front. See Figure 11. Use 8d nails or their equivalent.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 Figure 14 Figure 13 B - The following venting confi gurations may be installed (see Figure 14): 1 - Vertical - Minimum overall height of the vent system and appliance without an offset must be 10' (2.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 9 B. Electronic Wiring (See Figure s 17 or 18) – Note: The electronic appliance must be con- nected to the main power supply . A junction box is located at the rear of the con- trol compartment on either side of the cabinet.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 Gas Stub ¹₂ " x ³₈ " Flare Shut-Off Valve ³₈ " Flex T ubing ³₈ " NPT x ³₈ Flare Fitting ³₈ .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Figure 22 Figure 23 Figure 24 Burner Flame Appearance - Model MPB-3328 Burner Flame Appearance - Model MPB-3530 Burner Flame Appearance - Model MPB-4035 & MPB-4540 The packaged logs are located within the fi rebox.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Glowing Embers, Vermiculite, Decorative V olcanic Stone And Log Placement Instructions: Step 1. Separate the Glowing Embers (Rockwool) into pieces about the size of a quarter (see Figure 25) . Keep the pieces fl uffed up, not matted.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. MPB-3328 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. MPB-3530 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the rear log on the brackets at the rear of the fi rebox with the log's notches directly over the brackets.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. MPB-4035 & MPB-4540 LOG PLACEMENT 1 Position the individual logs as shown below . Logs should be placed in the order shown. Position the center log on the burner fi rst, then place the glowing embers as shown in Fig- ure 27.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 Step 10. CHECKING APPLIANCE OPERA- TION With gas line installed run initial system check- out before closing up the front of the unit. Follow the pilot lighting instructions provided in the Homeowner's Care and Operation Instructions.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Step 12. BURNER ADJUSTMENTS Note - The air shutter for the burner primar y air opening is factory-set. Do not adjust the factory-set position. The factor y-set position is shown in Figure 35. Step 14.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 18 Figure 37 Figure 38 COLD CLIMA TE INSULA TION If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 19 GAS CONVERSION KITS In Canada: THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HA VING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.
20 Figure 40 b. Attach manometer to the manifold side pressure test fi tting and verify manifold pres- sure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. c. Refer to Figure 40 and remove the pilot hood assembly to access the hexed pilot orifi ce.
デバイスMaxon Telecom MPB3328CNEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Maxon Telecom MPB3328CNEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaxon Telecom MPB3328CNEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Maxon Telecom MPB3328CNEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Maxon Telecom MPB3328CNEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Maxon Telecom MPB3328CNEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaxon Telecom MPB3328CNEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Maxon Telecom MPB3328CNEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaxon Telecom MPB3328CNEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。