flash is fired. The high energy of the flash light will burn the material or
damage the reflector screen if this is not observed.
The mecablitz 60 CT-1 is supplied complete with 60-38 battery and charger.
lead to severe visual disorders - even blindness!
creative scope regarding camera settings.
light and cause an accident!
1. Safety instructions
Outstanding features:
battery charge

flash mode in order to determine the correct aperture for a given sub-
hours. During this time, the red monitoring light remains illuminated. As
remains illuminated during the whole recharging procedure. After a further
The battery is exhausted when recycling after a full-power flash takes more
2.3 Switching the flash unit ON and OFF The flash unit is turned on with the main switch (fig. 5). The in-use
indicator (fig. 5) of the generator will then light up. Push the main
The mecablitz is ready for operation as soon as the flash-ready indi-
2.4 Flash ready indication The mecablitz is ready for operation as soon as the flash-ready indi-
This gives you the opportunity to manually fire a test flash in the auto
ject - a procedure that can be otherwise daunting with bounce flash
aperture, or the distance to the reflection surface or subject has to be
soon as the battery has been recharged up to 80% of its capacity the red
If the flash ready indicator ((fig. 3) is illuminated while the power
pack is switched off, then this indicates that the amount of light is no
If the exposure o.k. indicator (fig. 3) remains dark after firing a
monitoring light starts flashing. The green monitoring light (fig. 5)
than 30 seconds. An exhausted battery must be immediately recharged.
test flash, then the next lower f- number must be set to widen the
2.5 Correct exposure indication The exposure o.k. indicator (fig. 3) only lights up if the shot will
be/has been correctly exposed in automatic or TTL flash mode.
when the reflection conditions are difficult to judge in advance.
cator (fig. 3) lights up. Only then can a flash be fired.
The test flash is triggered with the manual firing button.
switch into position "0" to turn off the flash unit.
six hours the accumulator is then fully charged
longer sufficient for a correct exposure.
cator (fig. 3) lights up.
Be sure to switch off the mecablitz by its main switch prior to mounting
removing the flash unit, switch off both the camera and the flash unit!
Spent batteries must not be thrown into the domestic waste! Help keep
cover (fig. 5) and remove the inserted cardboard insulating strip between
The 60-38 rechargeable battery must only be charged with the battery char-
the environment clean and discard spent batteries at corresponding
Before using the mecablitz for the first time, open the battery compartment
or removing the standard foot or SCA adapter. Before mounting or
ger (Table 2, Page 513). The operating voltage must be set on the battery
Recharging an exhausted battery to 80% of its capacity takes approx. 7
2.1 Attaching the flashgun to a camera The flashgun can only be operated with synch cable on the camera.
2.2 Power supply The flash unit can only be operated with the 60-38 battery.
the 70-35 bracket (optional accessory).
charger prior to the charging operation.
2.2.1 Charging the battery
the battery and contacts.
Mounting the flashgun:
collecting points!

There is a certain measure of overlap between the individual automatic aper-
ted to the actual picture shooting situation by setting the corresponding aper-
At a flash-to-subject distance of 15 m (as in our example), an aperture
tures. As a result of this overlap it is always possible to place the subject wit-
Due to their design they can cause a loss of light in the order of up to
In this mode the flashgun will emit its full power. The flashgun can be adap-
The subject should be within the middle third of the distance range.
one f-stop. Furthermore, the effective aperture can also vary, depen-
ding upon the adjusted focal length. This must be compensated by
If the displayed value does not coincide with the actual distance, then the
This gives the electronic control sufficient scope for compensation
manually correcting the aperture setting on the flashgun!
Adjusting procedure for the manual flash mode:
aperture have to be changed accordingly.
hin the middle third of the range.
should this be necessary.
ture on the camera.
Example:
re to be set.
In the automatic flash mode the sensor (fig. 1) measures the light reflected
from the subject. The flash is cut off as soon as sufficient light has been emit-
In this manner there is no need to calculate and set a new aperture when the
The photosensor of the flashgun must be directed at the subject, regardless of
Direct the flash unit with its sensor for the test flash in the same man-
distance is changed, provided that the subject remains within the indicated
the direction at which the main reflector is pointing. The photosensor has a
measuring angle of approx. 25°, and it only measures the actual amount of
The f-stop established in this manner also has to be set on the
Six working apertures are available in the automatic flash mode.
Adjusting procedure for the automatic flash mode:
shortened. Thereafter repeat the test flash.
ner as for the subsequent flash shot.
light emitted by the flashgun.
ted for correct exposure.
automatic flash range.
Example:
camera.
ge.

In the winder/motordrive mode a series of pictures can be shot at the rate of
The aperture to be set on the camera is then indicated on the scale opposi-
5.2 Bounce flash in manual flash mode The required camera aperture in the manual flash mode is best established
with an exposure meter. Observe the following rule of thumb if an exposure
several frames per second. The winder mode is based on partial light output
to establish the guide value for the aperture that can then be varied by +1
Up to 2 flashes per second can be fired in the "Winder W" mode; up to 5
Setting procedure for picture shooting in the winder flash mode:
flashes per second are possible in the "Motordrive MD" mode.
Camera aperture =
light distance x 2
te the flash-to-subject distance.
f–stop for the actual exposure.
meter is not available
re to be set.
Definition:
levels.
of f/4 has to be set on the camera. The adjusted aperture must be cor-
Photos shot with full frontal flash are easily recognizable by their harsh, den-
se shadows. This is often associated with a sharp drop of light from the fore-
that the flash is bounce back from a suitable reflective surface (e.g. ceiling or
When swivelling the reflector vertically, it is essential to ensure that it is
fall on the subject. Therefore, always tilt the reflector to at least the 60°
structured (e.g. wooden beams in the ceiling) as this could cast shadows. For
5.1 Bounced flash in automatic and TTL flash modes It is advisable to check prior to the actual exposure whether the light is suffi-
cient for the selected aperture. Please refer to Ch. 2.5, for the corresponding
background. For this purpose the main reflector is turned in such a manner
For this reason the main reflector can be turned vertically and horizontally.
The diffused light bounced back from the reflective surfaces results in a soft
The reflecting surface must be white or a neutral colour, and it must not be
This phenomenon can be avoided with bounce flash because the diffused
light will produce a soft and uniform rendition of both the subject and the
The head can be swivelled horizontally to the left and right by 180°, and
turned by a sufficiently wide angle so that direct light can no longer
colour effects just select reflective surfaces in the required colour.
The following are the vertical lock-in positions for bounce flash:
rected when the wide-angle diffuser is used.
locks into position at 90° and 180°.
ground to the background.
illumination of the subject.
lock-in position.
walls of a room).
procedure.
guide number

When the wide-angle diffuser is being used in manual mode it will be neces-
great deal of light (e.g. backlit scenes), thereby resulting in subject overexpo-
9.1 Exposure correction in automatic flash mode To compensate the above mentioned effect, the exposure can be corrected by
In the auto flash mode, the flash coverage widened by the wide-angle diffu-
70% of their original value. The new maximum flash ranges are indicated at the bottom edge of the setting slide.
sary to set the next smaller f-number than the one indicated on the program-
opening or stopping down the camera’s aperture. With a bright background
If the wide-angle diffuser is not required, it should always be set in its park
ser reduces the maximum flash ranges of the working apertures to approx.
The automatic exposure systems are based on a subject reflection factor of
Dark backgrounds absorb a lot of light, while bright backgrounds reflect a
the sensor of the flashgun cuts out the flash too soon with the result that the
actual subject is too dark. With a dark background the flash is cut out too
25%, this being the average reflection factor for subjects shot with flash.
Open the camera aperture by 1/2 to 1 f-stop
late so that the actual subject is too bright.
Close the aperture by 1/2 to 1 f-stop
sure or underexposure, respectively.
position under the reflector.
(e.g. from f/5.6 to f/4).
(e.g. from f/8 to f/11).
Bright background:
Dark background:
ming centre.
The mecablitz can also be used for fill-in flash in daylight to soften harsh sha-
camera because the camera’s shutter speed is slower than the camera’s flash
To maintain a balanced range of highlights, for instance in order to retain the
the above example the camera was adjusted to f/8. Consequently, we advise
The wide-angle diffuser widens the horizontal lighting angle from 62° to 65°,
dows and lower the contrast, thereby producing a more balanced exposure
synch speed of the camera, e.g. 1/100 sec. (see operating instructions for
The two established values for aperture and shutter speed can be set on the
character of the shadows, it is advisable to select the automatic aperture on
the flashgun one setting lower than the aperture adjusted on the camera. In
When shooting into the light, ensure that the backlight does not shine
directly onto the sensor as this will confuse the flashgun’s electronics!
7.1 Fill-in flash in automatic mode Use the camera, or a hand-held exposure meter, to establish the required
aperture and shutter speed for a normal exposure. Ensure that the shutter
speed either equals, or is slower than, the fastest flash synch speed (varies
Established aperture = f/8; established shutter speed = 1/60 sec. Flash
The wide-angle diffuser is intended for use with focal lengths of less
than 28 . . 35 mm (for 24 x 36 mm), and less than 50 . .75 mm
you to set an aperture of f/5.6 on the flashgun.
and the vertical lighting angle from 42° to 60°.
when shooting against the light.
with the given camera model).
the given camera).
(for 6 x 6 cm).
synch speed.
Example:

Flash unit, bracket, 60-38 battery, generator, connecting cable, charger,
Swivelling ranges and locking positions of flash head:
Generator with 60-38 battery approx. 1850 g
synch cable 60-50, operating instructions.
Dimensions approx. in mm (wxhxd)
Flash unit 110 x 254 x 102
Generator126 x 165 x 58
Flash unit approx. 650 g
Included:
Weight:
The flash capacitor incorporated in the flashgun undergoes a physical chan-
ge when the flashgun is not switched on for prolonged periods. For this rea-
son it is necessary to switch on the flashgun for approx. 10 minutes every 3
months. The battery must supply sufficient power to light up the flash-ready
Remove dust and grime with a soft dry cloth, or a silicon-treated cloth. Do
160* . . .4500 . * at full light output
light within one minute after the flashgun was switched on.
not use detergents as these may damage the plastic parts.
5 Sek. (in M mode) . . . 0,25 Sek.
6 auto apertures at ISO 100/21°:
Guide numbers at ISO 100/21°:
Forming the flash capacitor
Number of flashes:
Flash durations:
Recycling time:
counter-clockwise 90° 180° · clockwise 90° 180°

- The device they powered switches itself off and indicates "Spent Batteries".
Please return spent batteries to collecting points should they exist in your
To ensure short-circuit safety please cover the battery poles with adhesive
Do not dispose of spent batteries with domestic rubbish.
- They no longer function properly after prolonged use.
Please return only fully discharged batteries.
Normally, batteries are fully discharged if:
tape.
Malfunctions and damage caused to the mecablitz 60 CT-1 due to the
use of accessories from other manufacturers are not covered by our
flashguns by a camera-triggered flash. Responds also to infrared light
Synch extension lead 60-54 (5 m) (Order No: 000060541)
flashgun. This frees the other hand for focusing.
beam. Does not require batteries.
shots are also possible.
coloured foil.
country! · guarantee!