Mitsubishi ElectronicsメーカーQA6ADPの使用説明書/サービス説明書
ページ先へ移動 of 20
QA6ADP QA Conversion Adapter Module User’s Manual QA6ADP Thank y ou fo r buying the M itsubi shi genera l-purp ose programmab le logic contro ller MELSEC- Q Series Prior to use , plea se re ad bo th this man ual and de tailed m anual thoroughly and familiar ize y ourself w ith the product.
1 Revisions * The manual number is no ted at the low er right o f the top cover. Print Date *Manual Number Revision Aug., 2007 IB(NA)-0800402-A First printing Mar.
2 CONTENTS 1. OVER VI EW.................................................................................................... 3 1.1 Ov ervi ew ............................................................................................... 3 1.2 Inclu ded Part s .
3 1. OVERVIEW 1.1 Overv iew This user’s manual describe s the sp ec ification s, con figuration dev ice, part names and setting, and implemen tation and installa tion o f the QA6ADP QA conversion adap ter module.
4 2. SYSTEM CONFIGURA TION 2.1 Sy stem C onfigur ation This sectio n describes the system co nfigura tion and re strictio ns when the QA6ADP is use d. (1) The QA6ADP+ A5 B/A6 B is only applicable for the Hig h Performance model QCPU (Q02CPU, Q02HCP U, Q06HCPU, Q12HCPU, and Q25HCPU).
5 2.2 Configur ation Device List (1) Extensi on base unit mounta ble on the QA6ADP The follow ing shows ex tension base units that can be mounted on the QA6ADP.
6 Product name Model Remarks High-speed coun ter module AD61, AD61S1 *1 A/D converter module A 68AD, A68AD-S2, A68ADN, A616AD ---- D/A converter module A62DA, A62DA-S1, A68DAV, A68DAI-S1, A616DAV, A61.
7 3. SPECIFICA TIONS 3.1 General Specif ications This sectio n describes general sp ecifi cations of the QA6ADP. Item Specificati ons Operating ambient temperat ure 0 to 55 Storage a mbient temperat u.
8 3.2 Performance Specifications This section de scribes performance specifications of the QA6ADP. Item Specificatio ns 5VDC internal curr ent consumption 110 mA External dimen sions *1 130 mm (5.11 in ch) (H) 73.5 mm (2.89 in ch) (W ) 74 (2.91 inch) mm (D) Weight 0.
9 4. PART NAMES A ND SETTING 4.1 Part Names This sectio n describes part name s of the QA6ADP. 1) 6) 2) 3) 4) 3) 7) 9) 8) 5) No. Name Application 1) Extensio n cable connector Connector for sendi ng/recei ving signals t o the mai n base unit or the oth er e xtension base un it and connecting an e xtension cab le.
10 4.2 Extension Stage Number Setting Set the number of extension stages to both the QA6ADP and the extension base uni t. The same stage number should be set to both the stage number setting connector o f the ex tension base unit a nd that of the QA6 A DP.
11 5. LOA DING A ND INST A LL A TION 5.1 Mounting/ Removal of QA6ADP (1) Mounting of the QA6ADP The follow ing shows p rocedure s for mounting the QA6AD P on the extension ba se uni t. Mount a board fixing s crew of the QA6ADP to a screw hole (A) at top left of the bo ard.
12 (2) Removal of the QA6ADP The follow ing shows p rocedure s for re moving the QA6 ADP from the extension ba se uni t. M ounting b racke t fixing s crew Disconnect an extens ion cable form the QA6ADP . Remove the adapter module mount i ng screws of the QA6ADP at two parts (top and bottom).
13 5.2 Connection/ Disconnection of Extension Cable (1) Precaution s for handling an ex tension cable • Do not step on an ex tension cable . • W hen lay ing an ex tension cable , the minimum bend radius of the cable should be 55 mm (2.17 in ch) or more.
14 • To connect an exte nsion cable to th e QA6ADP, remov e a sticker on the IN side connector. Sticke r QA6ADP Extens ion base uni t Base co ver IN side • To connect an exte nsion cable to the OUT side connector of the QA6ADP, remove the por tion (lid) und er the characters "OUT" by tools such as a flathead screw dri ver (5.
15 • Hold the connector part of an ex tension ca ble when connecting the extension cable to the QA6ADP. QA6ADP Exten sion base unit Connector Extensio n cable • Make sure to tigh ten fix ing scr ews of the ex tension cable connector a fter con necting the ex tension cable.
16 6. PRECAUTION FOR USING QA 6ADP 6.1 Current Consumpti on of QA6ADP Since 5VDC is supplied to the QA6ADP from the p ower supply module of the main ba se unit, take the current consum ption of the QA6A DP into considerati on when selecting the pow er supply module fo r the main base unit.
17 6.2 Voltage Drop of Extension Cable Since 5VDC is supplied to the QA6ADP from the p ower supply module mounted on the main ba se unit, the v oltage drop w ill be caused in the extension cable. If the spe c ified v oltage (4.75VDC o r mo re) i s not supplied to the IN sid e connector o f the Q A6ADP+A5 B/A6 B, wrong input/output may occur.
18 7. COMPA TIBLE MODELS LIST This chap ter descri bes ex ternal dimensions o f the QA6 ADP. 200 (7.87) 73.5 (2 .89) 130 (5.11) 74 (2.91) I/O POWER I/O I/O I/O I/O QA6ADP QA conver sion adapter mo dule 2 6-M4 screw (for mo unting module) Handle 4- 6mountin g hole (M5 mounting s crew) A series extensio n base u nit that you hav e already ha d 9 (0.
Warran ty Mitsubishi will no t be held lia ble fo r damage cau sed by factors f ound no t to be the cause of Mitsubishi; machine damage or lost pr ofits ca used by faul ts in th e Mitsubishi products;.
デバイスMitsubishi Electronics QA6ADPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsubishi Electronics QA6ADPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsubishi Electronics QA6ADPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsubishi Electronics QA6ADPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsubishi Electronics QA6ADPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsubishi Electronics QA6ADPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsubishi Electronics QA6ADPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsubishi Electronics QA6ADPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsubishi Electronics QA6ADPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。