Monessen HearthメーカーBUF400の使用説明書/サービス説明書
ページ先へ移動 of 20
.
2 61D1013 .
61D1013 3 9. The installation must conform with local codes or , in the absence of local codes, with the 10. This unit complies with ANSI Z21.
4 61D1013 Continuedfrompage3 15. An unvented gas-fired heater uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.
61D1013 5 The BUF 400 and BU F500 are vent -fr ee fi rebo xes and featu re a self cont aine d hea t-c irc ulat ing syst em. Th is un it al so features a 2-in1, flexible-face system that converts the circulating system into a radiant system in seconds.
6 61D1013 BUF400: 24 13 / 16 " 2 3 / 16 " 6 9 / 16 " 10 3 / 8 " 14 7 / 16 " BUF400: 40" BUF400: 36" 24 1 / 4 " 6 1 / 2 " 21 9 / 16 " 21" 34".
61D1013 7 17" 21 1 / 2 " BUF400: 35 1 / 2 " BUF400: 20 3 / 8 " BUF500: 26 3 / 8 " BUF500: 41 1 / 2 " .
8 61D1013 9" Minimum 42" Minimum 9" Minimum Ensure that minimum clearances shown in Figures 4 through 7 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation.
61D1013 9 12" 10" 8" 6" 2 1 / 2 " 12" 16" 19" 21" 23" and 4. The ca no py sup pl ie d w ith th e uni t must be installed.
10 61D1013 20 5 / 16 " 400: 40 1 / 4 " 400: 66 1 / 8 " 400: 24 13 / 16 " 500: 30 13 / 16 " 500: 46 1 / 4 " 500: 72 5 / 8 " 400: 46 3 / 4 " 500: 51 3 / 8 " .
61D1013 1 1 1. Bend out the nailing flanges located on each side of the firebox. 2. Slide the firebox into prepared framing or position firebox in its final position and frame later . 3. Level the firebox by checking the top edge of the firebox.
12 61D1013 Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.
61D1013 13 A canopy is furnished with each firebox and MUST be installed for safe operation. SeeFigure14. 1. Locate three (3) holes at the top of the front frame.
14 61D1013 If you are installing the forced air kit, Model F A2A, see the installation instructions provided with the kit for electri- cal wiring requirements, or the blower installation section.
61D1013 15 1 2 3 3 .
16 61D1013 8'max. 1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner .
61D1013 17 The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace.
18 61D1013 7. If the duct is the insulated type, push the insulation back from one end of the duct approximately 2".
61D1013 19.
The following components are warranted for life to the original owner , subject of proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate, and Stainless Steel Burners.
デバイスMonessen Hearth BUF400の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth BUF400をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth BUF400の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth BUF400の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth BUF400で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth BUF400を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth BUF400の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth BUF400に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth BUF400デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。