For use in U.S./Canada Underwriter's Laboratories Report No. MH7603 87D1504 12/09 Rev .
2 CW C Series W oodbur ning Fireplace 87D1504 .
3 CW C Series W oodb ur ning Fir eplace 87D1504 50" (1270mm) 42" (1067mm) 35 Z v " (895mm) 46" (1 168mm) B, " (16mm) B, " (16mm) Zx " (13mm) Zx " 19 Cv " (.
4 CW C Series W oodb ur ning Fir eplace 87D1504 Insulation methods shown are optional for cold climate, not a requirement for unit operation. FPC554 Fireplace and chase parts identification.
5 CW C Series W oodb ur ning Fir eplace 87D1504 D RISE B G H B OFFSET C E 6 FT . G H A HEARTH FLOOR CHIMNEY SECTION CHIMNEY FLUE EXIT ELBOW FPC269 Chimney Requirements -typ.
6 CW C Series W oodb ur ning Fir eplace 87D1504 Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
7 CW C Series W oodb ur ning Fir eplace 87D1504 The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth.
8 CW C Series W oodb ur ning Fir eplace 87D1504 Framing can be constructed before or after the fire- place is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
9 CW C Series W oodb ur ning Fir eplace 87D1504 Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished - how much pipe is required, the number of elbows, if any , and type of termination to be used.
10 CW C Series W oodb ur ning Fir eplace 87D1504 Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.
1 1 CW C Series W oodb ur ning Fir eplace 87D1504 An outside air kit is installed in all CWC Series Fire- places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors).
12 CW C Series W oodb ur ning Fir eplace 87D1504 FP593 SR/C 11/20/97 Installing firestop spacer . FP593 Nails (4) Firestop Spacer Joist .
13 CW C Series W oodb ur ning Fir eplace 87D1504 Size of roof hole varies with the type of chimney ter- mination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole.
14 CW C Series W oodb ur ning Fir eplace 87D1504 used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace open- ing to bottom of mantel shelf.
15 CW C Series W oodb ur ning Fir eplace 87D1504 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. MHSC - EH2416, K = .458, 1 inch thick required. A hearth extension is required to protect a combustible floor in front of the fireplace.
16 CW C Series W oodb ur ning Fir eplace 87D1504 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR /˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .
17 CW C Series W oodb ur ning Fir eplace 87D1504 Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.
18 CW C Series W oodb ur ning Fir eplace 87D1504 2-583 Parts page 3/2/99 djt 1 2 3 4 5 6 12 8 10 9 11 15 14a,b 17 16 18 OFF LOW 13 7 2 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
19 CW C Series W oodb ur ning Fir eplace 87D1504 The following accessories for this appliance are available from your local distributor . Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361; Attn: T echnical Services.
20 CW C Series W oodb ur ning Fir eplace 87D1504 Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (SK8) (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase.
21 CW C Series W oodb ur ning Fir eplace 87D1504 Square Chase T ermination Square chimney cap used to terminate chimney SL TS8 through chase.
22 CW C Series W oodb ur ning Fir eplace 87D1504.
23 CW C Series W oodb ur ning Fir eplace 87D1504 .
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
デバイスMonessen Hearth CWC400の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth CWC400をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth CWC400の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth CWC400の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth CWC400で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth CWC400を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth CWC400の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth CWC400に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth CWC400デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。