Monessen HearthメーカーGCUF Seriesの使用説明書/サービス説明書
ページ先へ移動 of 20
For use with a listed gas-fired unvented decorative room heater not to exceed 40,000 BTU/hr . Do Not Build a Wood Fire. READ AND SA VE THESE INSTRUCTIONS W ARNINGS If the information in this manual is not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life.
2 71D0530 CONTENTS Important Safety Information ................................. 3 Product Features ......................................................5 Before Y ou Start .....................................................5 General Installation Information .
71D0530 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.91 ventless firebox enclosures for gas-fired unvented decorative room heat- ers.
4 71D0530 IMPORT ANT SAFETY INFORMA TION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli- ance.
71D0530 5 The new GCUF and GRUF Series are vent-free fireboxes. They feature a self contained heat-circulating system. These units also feature a 2-in1, flexible-face system, sold as an accessory, that converts the circulating system into a radiant system in seconds.
6 71D0530 L J K 5 7/16" G F D E C 34 1/2" H A B I 1 1/4" 21 3/4" 6" 1 5/16" 2 1/2" 1 ¼" 5 7 / 16 " 21 ¾" 2 ½" 1 5 / 16 " 6" 34 ½&qu.
71D0530 7 E MINIMUM HEARTH DIMENSIONS GENERAL INST ALLA TION INFORMA TION AND LOCA TION OF FIREBOX Figure 2 - Minimum Hearth Dimensions LOCA TION OF FIREBOX Carefully select the best location for installation of your vent-free firebox.
8 71D0530 9" Minimum 42" Minimum 9" Minimum Ensure that minimum clearances shown in Figures 4 through 8 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation.
71D0530 9 4. Mantel clearances: The canopy supplied with the unit must be installed. If a combustible mantel is installed, it must meet the clearance requirements as shown in Figure 6a . However, if lower mantel height is desired, refer to page 14 and see Figure 6b.
10 71D0530 H G D F E A C B A 1 / 2 "o r 5 / 8 " C A G C G A 1 / 2 " or 5 / 8 FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figures 9 through 12 and the chart below for your specific installation requirements.
71D0530 11 K J FIREPLACE FRAMING GCUF32C with trim GCUF36C with trim GCUF42C with trim K 37 ⅞ " 41 ⅞ " 47 ⅞ " J 35 ⅞ " 35 ⅞ " 35 ⅞ " 1. Bend out the nailing flanges located on each side of the firebox. 2. Slide the firebox into prepared framing or position firebox in its final position and frame later.
12 71D0530 GAS LINE INST ALLA TION Consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA54. Remove the baseplate for ease of gas line installation.
71D0530 13 CANOPY INST ALLA TION INST ALLING CANOPY A canopy is furnished with each firebox and MUST be installed for safe operation. See Figure 14. 1. Align the canopy with the holes in the top frame. 2. Secure the screws as shown. 3. Tighten side screws.
14 71D0530 Electrical connections should only be performed by a quali fi ed, licensed electrician, main power must be off when connecting to main electrical power supply or performing service.
71D0530 15 4 1 5 6 4 2 3 7 ILLUSTRA TED P ARTS LIST ITEM DESCRIPTION QTY GCUF32C GCUF36C GCUF42C 1 Canopy 1 71D0023 71D0500 71D1000 2 Screen Panel 2 61D0001 61D0001 61D0003 3 Screen Rod 2 26D0138 26D0.
16 71D0530 8'max. FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT COMBUSTION AIR 1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner . Locate assembly a min. of 12" above the snow line to prevent blockage by snow accumulation.
71D0530 17 FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fi replace. Use the model AK4 combustion air kit.
18 71D0530 MODEL AK-4 COMBUSTION AIR ASSEMBL Y (CONTINUED) 7. If the duct is the insulated type, push the insulation back from one end of the duct approximately 2". See Figur e 23. 8. Slip the exposed end of the duct over the starting collar on the fi replace .
71D0530 19 NOTES.
MA Y 2008 P/N 71D0530 • Rev . 6 MONESSEN HEARTH SYSTEMS LIMITED LIFETIME W ARRANTY POLICY The following components are warranted for life to the original owner, subject of proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, and Stainless Steel Burners.
デバイスMonessen Hearth GCUF Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth GCUF Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth GCUF Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth GCUF Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth GCUF Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth GCUF Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth GCUF Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth GCUF Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth GCUF Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。