Monessen HearthメーカーHWB700HBの使用説明書/サービス説明書
ページ先へ移動 of 36
HWB700/HWB700HB M ODELS I NST ALLA TION , O PERA TION AND M AINTENANCE M ANUAL F OR R ESIDENTIAL I NST ALLA TION 53D9036. Rev 1 03/03 T HIS FIREPLACE IS U.
1 Y ou have chosen the finest wood burning fireplace available. Y our fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace.
1. Read these instructions entirely before beginning any part of the installation. Save these instructions for any future repairs. 2. Use these instructions as a guide during the installation of the fireplace.
5 3 O PERA TION G UIDELINES When a AK4 combustion air assembly and a combustion air duct are attached to the connecting point on the left of the fireplace, combustion air may enter the firebox through a dampered opening behind the left side panel.
6 4 C LEARANCES RESIDENTIAL INSTALLATION 53 3/8" 53 3/8" MAINTAIN 2" MIN. AIR SPACE MAINTAIN 2" MIN. AIR SPACE BETWEEN CHIMNEY AND BETWEEN CHIMNEY AND COMBUSTIBLES COMB.
C LEARANCES 5 NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES. NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES. 4 5/16 16 1/16 9 13/16 25 9/16 12 3/16 30 3/4 21 1.
F IREPLACE L OCA TION CAUTION: Do not install fireplace over carpeting. This fireplace does not weigh more than large pieces of furniture and can normally be located near a load bearing wall without requiring additional foundations or supports.
8' 0" LEVEL SOLID SURFACE FIRESTOP SPACER SEE NOTES JOIST INSULATE SAME AS CEILING NOTES: 1. MODEL LF-FS-2 FIRESTOP SPACER MUST BE USED. 2. LOCAL CODES MAY NOT REQUIRE FIRE STOPPING AT THE CEILING LEVEL FOR CHASE INSTALLATIONS, BUT IT IS RECOMMENDED FOR SAFETY AND REDUCING HEAT LOSS.
MULTIPLE STORY INSTALLATION ATTIC SPACE SINGLE STORY INSTALLATION WITH POOR LOCATION PREFERRED LOCATION 2" MIN. CLEARANCE 2" MIN.
9 F LOOR P ROTECTION If this fireplace is installed on a combustible floor , the floor area 20 inches in front of, and 12 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension.
52 7/8" 52 7/8" 27" 27" 53 1/8" 53 1/8" 68" 68" 20" 20" FLOOR FLOOR COMBUSTIBLE COMBUSTIBLE 26 3/8" 26 3/8" WARNING: THE HEARTH EXTENSION AN.
11 53D9036. Rev 1 03/03 F IREPLACE C OMPONENTS F IGURE 13.
F IREPLACE I NST ALLA TION L OCA TION S ELECTION Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your dealer . Before beginning the installation, be sure you have the proper parts in sufficient quantity .
13 53D9036. Rev 1 03/03 C HIMNEY I NST ALLA TION 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through. Unless the chimney is to be offset, the point where the center line of the chimney will pass through the ceiling and roof can be determined with a plumb line as shown by Figure 15.
IMAGINARY IMAGINARY CENTER POINT CENTER POINT ACTUAL ACTUAL CENTER POINT CENTER POINT CENTERLINE CENTERLINE OF CHIMNEY OF CHIMNEY PLUMB BOB PLUMB BOB PLUMB LINE PLUMB LINE TABLE 1 .
15 53D9036. Rev 1 03/03 C HIMNEY O FFSET I NST ALLA TION E LBOW I NST ALLA TION The following are important points that should be observed when installing elbows on the fireplace: 1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the surrounding structure.
C HIMNEY O FFSET AND C AP I NST ALLA TION CHIMNEY HOUSING INSTALL ROUND CHIMNEY CAP OR CONTINUE CHIMNEY TO PROPER HEIGHT AND STORM CO L STORM COLLAR FLASH FLASHING ROOF FIRESTOP SPACER AS REQUIRED HEIGHT EXCEEDS 24FT.
17 53D9036. Rev 1 03/03 C HIMNEY C AP I NST ALLA TION M ODEL LC C HIMNEY C AP S PECIAL N OTE : The proper height as previously explained is important to assure proper draft and safety . The chimney cap extends the flue outlet four inches above the top of the last section of chimney .
C HIMNEY H EIGHT AND O FFSET C HARTS 17 17 26 1/2 26 1/2 31 3/4 31 3/4 36 36 41 1/4 41 1/4 47 1/4 47 1/4 50 3/4 50 3/4 57 3/4 57 3/4 62 62 67 3/4.
19 53D9036. Rev 1 03/03 C HIMNEY C AP C HASE I NST ALLA TION The preinstalled chimney sections should be no more than 13 inches below the top of the chase. The installation should be planned so that either a two-foot or three-foot chimney section will be used for the top section.
O UTSIDE C OMBUSTION A IR P RECAUTIONS & R ECOMMENDA TIONS CONCRETE SLAB INSTALLATION (OPTIONAL OUTSIDE AIR RUNS) INLET GRILLE IN SOFFIT (OVERHANG) 8' MAX. FIRESTOP SPACER CAUTION: DO NOT TAKE COMBUSTION AIR FROM ATTIC SPACE OR GARAGE.
21 53D9036. Rev 1 03/03 O UTSIDE C OMBUSTION A IR P RECAUTIONS & R ECOMMENDA TIONS O UTSIDE C OMBUSTION A IR R ECOMMENDA TIONS ( CONTINUED ) 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided.
C OMBUSTION A IR A SSEMBL Y M ODEL AK-4 C OMBUSTION A IR A SSEMBL Y 1. Remove the cover plate from the 4-inch outlet opening location on the left outside of the fireplace.
23 53D9036. Rev 1 03/03 G AS A PPLIANCE I NST ALLA TION W ARNING : Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can cause serious injury or death to its inhabitants.
G AS A PPLIANCE I NST ALLA TION 7. Pack the insulation removed in step 4 around the pipe to prevent air flowing through the tube either into or out of the firebox.
25 53D9036. Rev 1 03/03 COMBUSTIBLE SURROUND PLACEMENT COMBUSTIBLE SURROUND MATERIALS COMBUSTIBLE SURROUND MATERIALS MAY BE PLACED INSIDE THE SHADED MAY BE PLACED INSIDE THE SHADED AREAS.
F IREPLACE O PERA TION W ARNING : If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open position. (See additional operation information in section titled “Operation Guidelines”.) A DV ANT AGES OF A W OOD B URNING F IREPLACE These are the practical, ecological advantages of wood as a fuel.
27 53D9036. Rev 1 03/03 F IREPLACE O PERA TION A F EW W ORDS OF C AUTION Beware of burning certain material in your fireplace. Among these are plastics, poison ivy twigs and stems, and chemically treated woods such as discarded poles and railroad ties.
M AINTENANCE AND S AFETY F UEL S T ORAGE W ood can be dried suf ficiently for burning within a few weeks if protected form rain in a low humidity area. It is far better to cut wood and allow it to dry for a year . In all cases, the wood should be stacked so that both ends of the sticks are exposed to the air and protected from rain.
29 53D9036. Rev 1 03/03 F IREPLACE M AINTENANCE At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical.
18. Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustible materials from the fireplace. 19. Do build fires of moderate intensity in the fireplace for the first three fires to allow materials to adjust and cure before being subjected to the intense heat of a large fire.
31 53D9036. Rev 1 03/03 P ARTS D IAGRAM AND L IST F IGURE 26 All repair part orders should be placed through your local dealer . T o ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number , and Quantity of parts needed.
32 53D9036. Rev 1 03/03 P ARTS D IAGRAM AND L IST F IGURE 27 All repair part orders should be placed through your local dealer . T o ensure prompt and accurate service, please provide the following information when placing a repair part order: Model number of your Appliance, Part Name, Part Number , and Quantity of parts needed.
33 53D9036. Rev 1 03/03 FACTORY-BUILT FIREPLACE AND COMPONENTS ( EXCEPT BLOWERS ) W HAT IS COVERED AND FOR HOW LONG •F IVE -Y EAR C OVERAGE - For five years from the date this fireplace and componen.
34 53D9036. Rev 1 03/03 L IMITED W ARRANTY Y OUR D UTIES This fireplace must be installed by a qualified installer according to your local building codes and installation instructions and operated according to the owner’s instructions. You must keep an invoice, canceled check or payment record to verify the purchase date of the fireplace.
A TTENTION A PPLIANCE I NST ALLER P LEASE RETURN THESE O PERA TING AND I NST ALLA TION I NSTRUCTIONS TO THE A PPLIANCE FOR C ONSUMER U SE . 53D9036. R EV 1 03/03.
デバイスMonessen Hearth HWB700HBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth HWB700HBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth HWB700HBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth HWB700HBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth HWB700HBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth HWB700HBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth HWB700HBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth HWB700HBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth HWB700HBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。