OWNER’S MANUAL MD1127 LIFE PRESERVER BY MUST ANG SURVIV AL PA3007_MD1127_23Apr99 3/13/06 9:48 AM Page 1.
T ABLE OF CONTENTS INTRODUCTION DESCRIPTION A. GENERAL B. THE MD1127 LIFE PRESERVER 1. DESIGN AND CONSTRUCTION 2. INFLA TION SYSTEM 3. INFLA TION CELL 4. F ASTENER 5. BEL T 6. MARKINGS 7. P ACKAGE OPERA TING INSTRUCTIONS A. THE BUOY ANCY CELL 1. DEFLA TING THE BUOY ANCY CELL 2.
INTRODUCTION Mustang inflatable life preservers are items of primary survival equipment, and as such, every precaution shall be tak en to assure proper storage , maintenance , and handling. The life of the wearer may well depend on the condition of the life preserver and the security of its attachments and equipment.
B. The MD1127 Life preser ver 1. Design and Construction The MD1127 incorporates a dual chamber inflatable cell, which is separated by an internal floating baf fle. The floating baffle allows either chamber to fully inflate the life preser ver . The life preser ver is styled as a protective collar fitted around the neck and front chest.
7. Package A bright yellow polyurethane coated nylon package is provided for storage purposes. The package is closed by a V elcro ® patch placed on its cover flap. This allows the package to be opened quickly in the event of an emergency . OPERA TING INSTRUCTIONS A.
Oral Inflation In the event that the CO 2 gas cylinder fails to inflate the buoyancy cell, or if the cell needs to be topped up during use, your inflatable life preser ver can be inflated by mouth through the inflation tube. T o inflate by mouth, depress the mouthpiece and blow into the tube until the cell is fully inflated.
7. Fold the top of the life preser ver towards the packer , over the folded ends; Figure 6c. 8. Slide life preser ver in this position into package bag as shown in Figure 6d. 9. Close V elcro ® patch. D. Laundering Procedures Do not dr y clean. Do not use chlorine bleach.
MAINTENANCE, INSPECTION AND TESTING PROCEDURES Y our life preser ver should be inspected and tested annually to maintain all compo- nents of the life preser ver , and its associated equipment in a ser viceable condition, and to ensure that the inflatable cell will withstand the specified pressure.
3. CO 2 Inflation V alve T est T o test the CO 2 inflation valve, operate the manual lever several times. Ensure the lever moves fully and that the piercing pin travels far enough to puncture sealing disk. Visually check to see that the piercing pin is in place, and protrudes sufficiently .
C. Repairs All repairs shall be conducted only by fully qualified, authorized technicians. Do not attempt to repair or replace any item or part of your life preser ver . Return all damaged life preser ver for repair to the Mustang Dealer where the item was purchased.
WE SA VE LIVES FOR A LIVING MUST ANG SURVIV AL CORP . T elephone: 1-800-526-0532 Email: custserv@mustangsurvival.com www .mustangsurvival.com P A3007 (Rev05Mar2012).
デバイスMustang Survival MD1127の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mustang Survival MD1127をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMustang Survival MD1127の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mustang Survival MD1127の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mustang Survival MD1127で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mustang Survival MD1127を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMustang Survival MD1127の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mustang Survival MD1127に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMustang Survival MD1127デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。