NapoleonメーカーGDS 28-Nの使用説明書/サービス説明書
ページ先へ移動 of 24
1 W415-0153 / A / 10.29.01 INST ALLA TION AND OPERA TION INSTRUCTIONS FOR: VENTED GAS FIREPLACE HEA TER NA TUR AL GAS MODELS GDS 28-N and GS 28-N PROP ANE GAS MODELS GDS 28-P and GS 28-P Model GS28 is made up of Model GDS28 and B-Vent Adapter Kit GS-150KT INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
2 W415-0153 / A / 10.29.01 PLEASE RET AIN THIS MANU AL FOR FUTURE REFERENCE Pg 13 GAS INST ALLA TION Remote Wall Switch / Thermostat 14 FINISHING Door Closing & Opening Log Placement 15 -1 6 OPERA.
3 W415-0153 / A / 10.29.01 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO9002 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0153 / A / 10.29.01 GENERAL INFORMA TION For your satisfaction, this stove has been test-fired to assure its operation and quality! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane.
5 W415-0153 / A / 10.29.01 MAINT AIN THESE MINIMUM CLEARANCES T O COMBUSTIBLES: A. 7" D. 14 3 / 4 " B. 2" E. 4" C. 1" * F. 9½" N O ADDITIONAL FLOOR PROTECTION IS REQUIRE.
6 W415-0153 / A / 10.29.01 HORIZONTAL RUN NOT TO EXCEED VERTICAL RISE SPECIAL INST ALLA TION EXAMPLE When a horizontal offset is required in a through-the-roof installation, the following procedure fo.
7 W415-0153 / A / 10.29.01 FIGURE 10 AIR AIR AIR AIR AIR TERMIN TERMIN TERMIN TERMIN TERMIN AL INST AL INST AL INST AL INST AL INST ALLA ALLA ALLA ALLA ALLA TIONS: TIONS: TIONS: TIONS: TIONS: * * * * .
8 W415-0153 / A / 10.29.01 VERTICAL INST ALLA TION: This application occurs when venting through a roof. FIGURE 3. Installation kits for vari- ous roof pitches are available from your Na- poleon dealer . See Ac- cessories to order the specific kit required.
9 W415-0153 / A / 10.29.01 VERTICAL VENTING INST ALLA TION 1. Fasten the roof support to the roof us- ing the screws pro- vided. The roof support is optional. In this case the venting is to be ad- equately supported using either an alter- nate method suitable to the authority having jurisdiction or the op- tional roof support.
10 W415-0153 / A / 10.29.01 Ensure that the sealant is not visible on the exte- rior pipes once installation is completed. An op- tional decorative brass band is available for this use . (Standard with a GD175 k it). In the ev ent that the venting must be disassembled, care must be taken to reseal the venting.
11 W415-0153 / A / 10.29.01 COMBUSTION AIR COVER PLA TES & GASKETS INST INST INST INST INST ALLING 'B' ALLING 'B' ALLING 'B' ALLING 'B' ALLING 'B' VENT VENT VENT VENT VENT : : : : : Follow the instructions for " Wall and Ceiling Protection".
12 W415-0153 / A / 10.29.01 For aesthetics, the adapter has been designed to accept a standard matte black 7" stove pipe and the Napoleon decorative brass band (standard with the GS-150KT). Both are available from your Napoleon dealer . B-VENT MODEL GS28 ONL Y : Attach the B-V ent label, shown below , in the control area of the appliance.
13 W415-0153 / A / 10.29.01 Mark the appropriate boxes on the rating plate label to indi- cate the model type depending on the installation (direct vent or B-vent). Read the section on opening the door in "Finishing" prior to proceeding to prevent damaging the unit.
14 W415-0153 / A / 10.29.01 DOOR CLOSING AND OPENING When installing the fire viewing door , a simple procedure must be followed in order to not damage the door . First open both side doors fully . Insert the pins on the door left side into the hinge bushings.
15 W415-0153 / A / 10.29.01 OPERA TING INSTRUCTIONS The on-off switch is located on the back of the unit at the top left corner on models GDS28 and GS28.
16 W415-0153 / A / 10.29.01 LIGHTING INSTRUCTIONS WARNING: WARNING: WARNING: WARNING: WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool.
17 W415-0153 / A / 10.29.01 REPLACEMENT BLOWER Blower replacement may be done through either the firebox or from the rear of the unit. Using the rear panel is recommended. 1. Turn off the electrical power and the gas supply to the stove. INST ALLA TION THR OUGH THE REAR P ANEL: FOR MODEL GDS28 2.
18 W415-0153 / A / 10.29.01 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
19 W415-0153 / A / 10.29.01 included with GD175 included with GD180 REPLACEMENTS ORDERING REPLACEMENT P AR TS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
20 W415-0153 / A / 10.29.01 P A R T # DESCRIPTION REPLA CEMENT P ARTS: GDS28/GS28 W725-0035 SIT V AL VE - NG W725-0034 SIT V AL VE - LP W100-0056 BURNER W455-0026 #38 BURNER ORIFICE - NG W455-0003 #54.
21 W415-0153 / A / 10.29.01 Pilot burning; no gas to main burner; gas knob is on 'HI'; wall switch / thermostat is on. Main burner orifice is plugged. Faulty thermopile. Faulty themostat or switch. - remove stoppage in orifice. - replace. Faulty valve.
22 W415-0153 / A / 10.29.01 PROBLEM TEST SOLUTION SYMPT OM Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL GDS28 ONL Y) - check joint seals and installation.
23 W415-0153 / A / 10.29.01 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
24 W415-0153 / A / 10.29.01 NOTES:.
デバイスNapoleon GDS 28-Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon GDS 28-Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon GDS 28-Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon GDS 28-Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon GDS 28-Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon GDS 28-Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon GDS 28-Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon GDS 28-Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon GDS 28-Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。